+86 13348028050
LTMR27CFM Schneider Electric LTMR27CFM - Front View | Vcocnc FANUC Parts

Schneider Electric LTMR27CFM

Product information

SKU: LTMR27CFM

Alternate: LTMR27CFM

Brand
Schneider Electric
Part No.
LTMR27CFM
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LTMR27CFM Product overview The Schneider Electric LTMR27CFM is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG output 0.5 A gG control circuit - Bus type: CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable - Characteristic: Value(s) - Communication Port Protocol: CANopen - Connection pitch: 0.20 in (5.08 mm) - Connections - terminals: Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end - Contacts type and composition: 1 NO + 1 NC fault signal 3 NO - Current Consumption: 8...62.8 mA - Current state 0 guaranteed: Logic input 0...40 V <= 15 mA 25 ms - Current state 1 guaranteed: Logic input 79...264 V >= 2 mA 25 ms - Device Application: Equipment monitoring and control - Device short name: LTMR - Electromagnetic compatibility: Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, - Input current: 3.1 mA 100 V 7.5 mA 240 V - Load current: 5 A 250 V AC logic output 5 A 30 V DC logic output - Logic input number: 6 - Maximum operating rate: 1800 cyc/h - Measurement accuracy: 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power - Measurement current: 1.35…27 A - Metering type: Temperature Earth-fault current Phase current I1, I2, I3 RMS Imbalance current Average current Iavg - Network and machine diagnosis type: Trip history information Starting current and time Fault recording Running hours counter/operating time Motor control command recording Phase fault and earth fault trip counters Waiting time after overload tripping Remaining operating time before overload tripping Trip context information Event recording - Overvoltage category: III - Permissible power: 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) - Product or Component Type: Motor controller - Protection Type: Overload (long time) Power factor variation Phase unbalance Reverse polarity protection Locked rotor Thermal overload protection Earth-leakage protection Thermal protection Phase failure Overload Load fluctuation - Range: TeSys - Short-circuit withstand: 100 kA conforming to EN/IEC 60947-4-1 - Supply voltage limits: 93.5…264 V AC - Tightening torque: Control circuit: 4.4…5.3 lbf.in (0.5…0.6 N.m) flat screwdriver 0.1 in (3 mm) - [Ui] rated insulation voltage: 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 - [Uimp] rated impulse withstand voltage: 4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 - [Us] rated supply voltage: 100...240 V AC 50/60 Hz - maximum output switching frequency: 2 Hz - pollution degree: 3 - product name: TeSys T Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LTMR27CFM with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LTMR27CFM
Brand
Schneider Electric
Part Number
LTMR27CFM
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Bus type
CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable
Load current
5 A 250 V AC logic output 5 A 30 V DC logic output
product name
TeSys T
Input current
3.1 mA 100 V 7.5 mA 240 V
Metering type
Temperature Earth-fault current Phase current I1, I2, I3 RMS Imbalance current Average current Iavg
Characteristic
Value(s)
Protection Type
Overload (long time) Power factor variation Phase unbalance Reverse polarity protection Locked rotor Thermal overload protection Earth-leakage protection Thermal protection Phase failure Overload Load fluctuation
Connection pitch
0.20 in (5.08 mm)
pollution degree
3
Device short name
LTMR
Permissible power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Tightening torque
Control circuit: 4.4…5.3 lbf.in (0.5…0.6 N.m) flat screwdriver 0.1 in (3 mm)
Device Application
Equipment monitoring and control
Logic input number
6
Current Consumption
8...62.8 mA
Measurement current
1.35…27 A
Measurement accuracy
5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power
Overvoltage category
III
Supply voltage limits
93.5…264 V AC
Associated fuse rating
4 A gG output 0.5 A gG control circuit
Maximum operating rate
1800 cyc/h
Connections - terminals
Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
Short-circuit withstand
100 kA conforming to EN/IEC 60947-4-1
Product or Component Type
Motor controller
[Us] rated supply voltage
100...240 V AC 50/60 Hz
Current state 0 guaranteed
Logic input 0...40 V <= 15 mA 25 ms
Current state 1 guaranteed
Logic input 79...264 V >= 2 mA 25 ms
Communication Port Protocol
CANopen
Contacts type and composition
1 NO + 1 NC fault signal 3 NO
Electromagnetic compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V,
[Ui] rated insulation voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
Network and machine diagnosis type
Trip history information Starting current and time Fault recording Running hours counter/operating time Motor control command recording Phase fault and earth fault trip counters Waiting time after overload tripping Remaining operating time before overload tripping Trip context information Event recording
maximum output switching frequency
2 Hz
[Uimp] rated impulse withstand voltage
4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1

Compatibility Information

Match LTMR27CFM against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LTMR27CFM.

Maintenance Tips

Store LTMR27CFM dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options