+86 13348028050
LTMR100DBD Schneider Electric LTMR100DBD - Front View | Vcocnc FANUC Parts

Schneider Electric LTMR100DBD

Product information

SKU: LTMR100DBD

Alternate: LTMR100DBD

Brand
Schneider Electric
Part No.
LTMR100DBD
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LTMR100DBD Product overview The Schneider Electric LTMR100DBD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 4 A gG output 0.5 A gG control circuit - Bus type: DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable - Characteristic: Value(s) - Communication Port Protocol: DeviceNet - Connection pitch: 0.20 in (5.08 mm) - Connections - terminals: Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end - Contacts type and composition: 1 NO + 1 NC fault signal 3 NO - Current Consumption: 56...127 mA - Current state 0 guaranteed: Logic input < 5 V <= 15 mA 5 ms - Current state 1 guaranteed: Logic input < 15 V 2...15 mA 15 ms - Device Application: Equipment monitoring and control - Device short name: LTMR - Electromagnetic compatibility: Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temper - Input current: 7 mA - Load current: 5 A 250 V AC logic output 5 A 30 V DC logic output - Logic input number: 6 - Maximum operating rate: 1800 cyc/h - Measurement accuracy: 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02 current - Measurement current: 5…100 A - Metering type: Temperature Average current Iavg Imbalance current Earth-fault current Phase current I1, I2, I3 RMS - Network and machine diagnosis type: Running hours counter/operating time Starting current and time Trip context information Remaining operating time before overload tripping Fault recording Phase fault and earth fault trip counters Event recording Trip history information Waiting time after overload tripping Motor control command recording - Overvoltage category: III - Permissible power: 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output) - Product or Component Type: Motor controller - Protection Type: Earth-leakage protection Overload Reverse polarity protection Thermal protection Overload (long time) Load fluctuation Phase failure Thermal overload protection Power factor variation Locked rotor Phase unbalance - Range: TeSys - Short-circuit withstand: 100 kA conforming to EN/IEC 60947-4-1 - Supply voltage limits: 20.4…26.24 V DC - Tightening torque: Control circuit: 4.4…5.3 lbf.in (0.5…0.6 N.m) flat screwdriver 0.1 in (3 mm) - [Ui] rated insulation voltage: 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508 - [Uimp] rated impulse withstand voltage: 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1 - [Us] rated supply voltage: 24 V DC - maximum output switching frequency: 2 Hz - pollution degree: 3 - product name: TeSys T Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LTMR100DBD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LTMR100DBD
Brand
Schneider Electric
Part Number
LTMR100DBD
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Bus type
DeviceNet ISO 1198 1...64 125...500 kbit/s, terminal block 4 twisted shielded pairs cable
Load current
5 A 250 V AC logic output 5 A 30 V DC logic output
product name
TeSys T
Input current
7 mA
Metering type
Temperature Average current Iavg Imbalance current Earth-fault current Phase current I1, I2, I3 RMS
Characteristic
Value(s)
Protection Type
Earth-leakage protection Overload Reverse polarity protection Thermal protection Overload (long time) Load fluctuation Phase failure Thermal overload protection Power factor variation Locked rotor Phase unbalance
Connection pitch
0.20 in (5.08 mm)
pollution degree
3
Device short name
LTMR
Permissible power
480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Tightening torque
Control circuit: 4.4…5.3 lbf.in (0.5…0.6 N.m) flat screwdriver 0.1 in (3 mm)
Device Application
Equipment monitoring and control
Logic input number
6
Current Consumption
56...127 mA
Measurement current
5…100 A
Measurement accuracy
5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 5 % active and reactive power 0,02 current
Overvoltage category
III
Supply voltage limits
20.4…26.24 V DC
Associated fuse rating
4 A gG output 0.5 A gG control circuit
Maximum operating rate
1800 cyc/h
Connections - terminals
Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004…0.004 in² (0.25…2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003…0.004 in² (0.2…2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008…0.002 in² (0.5…1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003…0.002 in² (0.2…1 mm²) AWG 24...AWG 14)solid without cable end
Short-circuit withstand
100 kA conforming to EN/IEC 60947-4-1
Product or Component Type
Motor controller
[Us] rated supply voltage
24 V DC
Current state 0 guaranteed
Logic input < 5 V <= 15 mA 5 ms
Current state 1 guaranteed
Logic input < 15 V 2...15 mA 15 ms
Communication Port Protocol
DeviceNet
Contacts type and composition
1 NO + 1 NC fault signal 3 NO
Electromagnetic compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temper
[Ui] rated insulation voltage
690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
Network and machine diagnosis type
Running hours counter/operating time Starting current and time Trip context information Remaining operating time before overload tripping Fault recording Phase fault and earth fault trip counters Event recording Trip history information Waiting time after overload tripping Motor control command recording
maximum output switching frequency
2 Hz
[Uimp] rated impulse withstand voltage
6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1

Compatibility Information

Match LTMR100DBD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LTMR100DBD.

Maintenance Tips

Store LTMR100DBD dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options