Schneider Electric LTMR08CBD
Product information
$889.35 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: LTMR08CBD
Alternate: LTMR08CBD
Brand
Schneider Electric
Part No.
LTMR08CBD
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LTMR08CBD
Product overview
The Schneider Electric LTMR08CBD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 4 A gG output 0.5 A gG control circuit
- Bus type: CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable
- Characteristic: Value(s)
- Communication Port Protocol: CANopen
- Connection pitch: 0.20 in (5.08 mm)
- Connections - terminals: Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008â¦0.002 in² (0.5â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)solid without cable end
- Contacts type and composition: 1 NO + 1 NC fault signal 3 NO
- Current Consumption: 56...127 mA
- Current state 0 guaranteed: Logic input < 5 V <= 15 mA 5 ms
- Current state 1 guaranteed: Logic input < 15 V 2...15 mA 15 ms
- Device Application: Equipment monitoring and control
- Device short name: LTMR
- Electromagnetic compatibility: Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperatu
- Input current: 7 mA
- Load current: 5 A 250 V AC logic output 5 A 30 V DC logic output
- Logic input number: 6
- Maximum operating rate: 1800 cyc/h
- Measurement accuracy: 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power
- Measurement current: 0.4â¦8 A
- Metering type: Average current Iavg Phase current I1, I2, I3 RMS Temperature Earth-fault current Imbalance current
- Network and machine diagnosis type: Trip context information Remaining operating time before overload tripping Starting current and time Event recording Motor control command recording Running hours counter/operating time Waiting time after overload tripping Trip history information Phase fault and earth fault trip counters Fault recording
- Overvoltage category: III
- Permissible power: 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Product or Component Type: Motor controller
- Protection Type: Overload (long time) Phase failure Load fluctuation Phase imbalance Reverse polarity protection Thermal protection Thermal overload protection Earth-leakage protection Power factor variation Overload Locked rotor
- Range: TeSys
- Short-circuit withstand: 100 kA conforming to EN/IEC 60947-4-1
- Supply voltage limits: 20.4â¦26.24 V DC
- Tightening torque: Control circuit: 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) flat screwdriver 0.1 in (3 mm)
- [Ui] rated insulation voltage: 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
- [Uimp] rated impulse withstand voltage: 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
- [Us] rated supply voltage: 24 V DC
- maximum output switching frequency: 2 Hz
- pollution degree: 3
- product name: TeSys T
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LTMR08CBD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LTMR08CBD
- Brand
- Schneider Electric
- Part Number
- LTMR08CBD
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Bus type
- CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable
- Packaging
- New surplus, never used
- Load current
- 5 A 250 V AC logic output 5 A 30 V DC logic output
- product name
- TeSys T
- Input current
- 7 mA
- Metering type
- Average current Iavg Phase current I1, I2, I3 RMS Temperature Earth-fault current Imbalance current
- Characteristic
- Value(s)
- Protection Type
- Overload (long time) Phase failure Load fluctuation Phase imbalance Reverse polarity protection Thermal protection Thermal overload protection Earth-leakage protection Power factor variation Overload Locked rotor
- Connection pitch
- 0.20 in (5.08 mm)
- pollution degree
- 3
- Device short name
- LTMR
- Permissible power
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Tightening torque
- Control circuit: 4.4â¦5.3 lbf.in (0.5â¦0.6 N.m) flat screwdriver 0.1 in (3 mm)
- Device Application
- Equipment monitoring and control
- Logic input number
- 6
- Current Consumption
- 56...127 mA
- Measurement current
- 0.4â¦8 A
- Measurement accuracy
- 5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power
- Overvoltage category
- III
- Supply voltage limits
- 20.4â¦26.24 V DC
- Associated fuse rating
- 4 A gG output 0.5 A gG control circuit
- Maximum operating rate
- 1800 cyc/h
- Connections - terminals
- Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004â¦0.004 in² (0.25â¦2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003â¦0.004 in² (0.2â¦2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008â¦0.002 in² (0.5â¦1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003â¦0.002 in² (0.2â¦1 mm²) AWG 24...AWG 14)solid without cable end
- Short-circuit withstand
- 100 kA conforming to EN/IEC 60947-4-1
- Product or Component Type
- Motor controller
- [Us] rated supply voltage
- 24 V DC
- Current state 0 guaranteed
- Logic input < 5 V <= 15 mA 5 ms
- Current state 1 guaranteed
- Logic input < 15 V 2...15 mA 15 ms
- Communication Port Protocol
- CANopen
- Contacts type and composition
- 1 NO + 1 NC fault signal 3 NO
- Electromagnetic compatibility
- Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperatu
- [Ui] rated insulation voltage
- 690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508
- Network and machine diagnosis type
- Trip context information Remaining operating time before overload tripping Starting current and time Event recording Motor control command recording Running hours counter/operating time Waiting time after overload tripping Trip history information Phase fault and earth fault trip counters Fault recording
- maximum output switching frequency
- 2 Hz
- [Uimp] rated impulse withstand voltage
- 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1
Compatibility Information
Match LTMR08CBD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LTMR08CBD.
Maintenance Tips
Store LTMR08CBD dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LTMR08CBD is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LTMR08CBD is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LTMR08CBD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW