+86 13348028050
LR-XN11P KEYENCE LR-XN11P - Front View | Vcocnc FANUC Parts

KEYENCE LR-XN11P

Product information

$341.96 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LR-XN11P

Alternate: LRXN11P

Brand
KEYENCE
Part No.
LR-XN11P
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE LR-XN11P Product overview The KEYENCE LR-XN11P is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Accessories: Instruction manual - Cable/Connector: Cable - Case Material: Main Unit and Cover: Polycarbonate - Environmental resistance / Ambient temperature: −20 to +55°C -4°F to 131°F (no freezing) *4 - External Input: External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable Short circuit current - PNP: 2 mA or lower Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected) - Functions / Timer Function: Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot - I/O / Control Output: Open collector, 30 VDC or lower, N.O./N.C. When used as a solitary unit: 100 mA or lower for 1 output - IO-Link: — - Main Unit/Expansion Unit: Main Unit - No. of Control Outputs: 2 - No. of External Inputs: 1 - Number of Interference Prevention Devices: OFF/4 units/8 units selectable *2 - Power Spectral Density: 0.816 G 2 /Hz - Power consumption: During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current) - Power supply / Power voltage: 16 to 30 VDC *3 (including 10% ripple (P-P) or less), class 2 - Protection Circuit: Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection - Relative humidity: 35 to 85% RH (no condensation) - Response Time: 500 µs *1 /1 ms/3 ms/10 ms/200 ms Selectable - Shock resistance: 500 m/s 2 (50G) - Type: PNP Output - Unit Expansion: Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series. - Vibration resistance: 10 to 500 Hz - Weight: Approx. 80 g - When expanding with multiple units: 50 mA or lower for 1 output Residual voltage PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA) Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LR-XN11P with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LR-XN11P
Brand
KEYENCE
Part Number
LR-XN11P
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
PNP Output
Weight
Approx. 80 g
IO-Link
—
Packaging
New surplus, factory sealed original packaging
Accessories
Instruction manual
Case Material
Main Unit and Cover: Polycarbonate
Response Time
500 µs *1 /1 ms/3 ms/10 ms/200 ms Selectable
External Input
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable Short circuit current - PNP: 2 mA or lower Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)
Unit Expansion
Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.
Cable/Connector
Cable
Shock resistance
500 m/s 2 (50G)
Power consumption
During normal operation: 1150 mW (47 mA or lower at 24 V, 64 mA or lower at 16 V), ECO ON/ALL: 985 mW (40 mA or lower at 24 V, 53 mA or lower at 16 V) (excluding Load Current)
Relative humidity
35 to 85% RH (no condensation)
Protection Circuit
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection
I/O / Control Output
Open collector, 30 VDC or lower, N.O./N.C. When used as a solitary unit: 100 mA or lower for 1 output
Vibration resistance
10 to 500 Hz
No. of Control Outputs
2
No. of External Inputs
1
Power Spectral Density
0.816 G 2 /Hz
Main Unit/Expansion Unit
Main Unit
Functions / Timer Function
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot
Power supply / Power voltage
16 to 30 VDC *3 (including 10% ripple (P-P) or less), class 2
When expanding with multiple units
50 mA or lower for 1 output Residual voltage PNP: 1.6 V or lower (output current: 10 mA or lower)/2.2 V or lower (output current: 10 to 100 mA)
Number of Interference Prevention Devices
OFF/4 units/8 units selectable *2
Environmental resistance / Ambient temperature
−20 to +55°C -4°F to 131°F (no freezing) *4

Compatibility Information

Match LR-XN11P against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing LR-XN11P.

Maintenance Tips

Store LR-XN11P dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114