+86 13348028050
LR-X250CG KEYENCE LR-X250CG - Front View | Vcocnc FANUC Parts

KEYENCE LR-X250CG

Product information

$1,827.86 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LR-X250CG

Alternate: LRX250CG

Brand
KEYENCE
Part No.
LR-X250CG
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE LR-X250CG Product overview The KEYENCE LR-X250CG is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Accessories: Instruction manual, laser warning label - Ambient light: Incandescent lamp: 8000 lux or less Sunlight: 8000 lux or less - Ambient temperature: -10°C to +50°C 14°F to + 122°F (no freezing) - Amplifier Display, Indicator: PAR - Amplifier Gasket: NBR - Button: POM Amplifier M8 Connector: SUS303 - Detecting Distance: 30 to 250 mm 1.18" to 9.84" - Display Resolution: 1 to 2 mm 0.04" to 0.08" - Environmental resistance / Enclosure rating: IP65/IP67 (IEC60529) - External Input: External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower Input time 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF when External Set is selected only) - Functions / Timer Function: Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot - Head Lens Cover: PSU Head Gasket: FKM (lens cover), EVM (cable) Cable: PVC - I/O / Control Output: NPN open collector/PNP open collector, N.O./N.C selectable. *4 30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower - IO-Link: Specification v1.1/COM2 (38.4 kbps) - Laser Class: Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10 *3 ) - Light Source / Type: Green laser (505 nm) - Material: Head Case: SUS316L - Metal Jacket: SUS304 Amplifier Case: PBT - Power Spectral Density: 0.816 G 2 /Hz for X, Y and Z axes - Power consumption: During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current) - Power supply / Power voltage: 16 to 30 VDC (including 10% ripple (P-P) or less), class 2 - Protection Circuit: Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection - Relative humidity: 35 to 85% RH (no condensation) - Response Time: 500 µs *2 /1 ms/3 ms/10 ms/200 ms Selectable - Shock resistance: 1000 m/s 2 (100G) 6 times each for X, Y, and Z axes - Spot Size: Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" (at a detecting distance of 250 mm 9.84" ) - Standard Detectable Deviation: 30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" 180 to 250 mm: 18 mm 7.09" to 9.84": 0.71" - Type: M8 Connector Type *1 - Vibration resistance: 10 to 500 Hz - Weight: Approx. 45 g Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LR-X250CG with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LR-X250CG
Brand
KEYENCE
Part Number
LR-X250CG
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
M8 Connector Type *1
Button
POM Amplifier M8 Connector: SUS303
Weight
Approx. 45 g
IO-Link
Specification v1.1/COM2 (38.4 kbps)
Material
Head Case: SUS316L
Packaging
New surplus, factory sealed original packaging
Spot Size
Approx. 0.8 mm × 1.2 mm 0.03" × 0.05" (at a detecting distance of 250 mm 9.84" )
Accessories
Instruction manual, laser warning label
Laser Class
Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10 *3 )
Metal Jacket
SUS304 Amplifier Case: PBT
Ambient light
Incandescent lamp: 8000 lux or less Sunlight: 8000 lux or less
Response Time
500 µs *2 /1 ms/3 ms/10 ms/200 ms Selectable
External Input
External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable *4 Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower Input time 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF when External Set is selected only)
Head Lens Cover
PSU Head Gasket: FKM (lens cover), EVM (cable) Cable: PVC
Amplifier Gasket
NBR
Shock resistance
1000 m/s 2 (100G) 6 times each for X, Y, and Z axes
Power consumption
During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current) ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)
Relative humidity
35 to 85% RH (no condensation)
Detecting Distance
30 to 250 mm 1.18" to 9.84"
Display Resolution
1 to 2 mm 0.04" to 0.08"
Protection Circuit
Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection
Ambient temperature
-10°C to +50°C 14°F to + 122°F (no freezing)
Light Source / Type
Green laser (505 nm)
I/O / Control Output
NPN open collector/PNP open collector, N.O./N.C selectable. *4 30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower
Vibration resistance
10 to 500 Hz
Power Spectral Density
0.816 G 2 /Hz for X, Y and Z axes
Functions / Timer Function
Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot
Amplifier Display, Indicator
PAR
Power supply / Power voltage
16 to 30 VDC (including 10% ripple (P-P) or less), class 2
Standard Detectable Deviation
30 to 180 mm: 9 mm 1.18" to 7.09": 0.35" 180 to 250 mm: 18 mm 7.09" to 9.84": 0.71"
Environmental resistance / Enclosure rating
IP65/IP67 (IEC60529)

Compatibility Information

Match LR-X250CG against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing LR-X250CG.

Maintenance Tips

Store LR-X250CG dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114