+86 13348028050
LR-W500 KEYENCE LR-W500 - Front View | Vcocnc FANUC Parts

KEYENCE LR-W500

Product information

$378.14 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LR-W500

Alternate: LRW500

Brand
KEYENCE
Part No.
LR-W500
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE LR-W500 Product overview The KEYENCE LR-W500 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient light: Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less - Ambient temperature: -20 to +50 °C -4 to 122 °F (No freezing) - Current consumption: 65 mA or less (without load) at 24 VDC - Detecting distance: 30 to 500 mm 1.18" to 19.69" - Environmental resistance / Enclosure rating: IP65/IP67 (IEC60529) - External input: Tuning /Transmission OFF selectable Short circuit current: 1 mA or less for NPN/2 mA or less for PNP For the applied voltage, see the wiring diagrams in the instruction manual. For the input times, see the time charts in the instruction manual. *2 - I/O / Control output: NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, remaining voltage: 2 V or less N.O./N.C. selectable *2 - Light source: White LED - Material: Case: Zinc die cast (Nickel chrome plating), Indicator cover: PPSU, Buttons: PES Lens cover and display: PMMA (scratch-resistant coating), Cable bushing: PBT, Cable: PVC, Spot adjustment dial: Iron (triiron tetraoxide coated) - Min. spot diameter: Adjustable spot Approx. ø3.5 mm at 100 mm ø0.14" at 3.94" Approx. ø9 mm at 250 mm ø0.35" at 9.84" Approx. ø18 mm at 500 mm ø0.71" at 19.69" - Mutual interference reduction function: Up to 2 units when alternate frequencies set - Power supply / Power voltage: 10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS - Protection circuit: Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection - Relative humidity: 35 to 85 % RH (No condensation) - Response time: 200 µs/1 ms/10 ms/100 ms/500 ms selectable *1 - Shock resistance: 1,000 m/s 2 , 6 times in each of the X, Y, and Z directions - Timer: OFF/ON delay/OFF delay/One-shot - Type: 2 m 6.56' cable type - Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions - Weight: Approx. 170 g (including cable) Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LR-W500 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LR-W500
Brand
KEYENCE
Part Number
LR-W500
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
2 m 6.56' cable type
Timer
OFF/ON delay/OFF delay/One-shot
Weight
Approx. 170 g (including cable)
Material
Case: Zinc die cast (Nickel chrome plating), Indicator cover: PPSU, Buttons: PES Lens cover and display: PMMA (scratch-resistant coating), Cable bushing: PBT, Cable: PVC, Spot adjustment dial: Iron (triiron tetraoxide coated)
Packaging
New surplus, factory sealed original packaging
Light source
White LED
Ambient light
Incandescent lamp: 10,000 lux or less, Sunlight: 20,000 lux or less
Response time
200 µs/1 ms/10 ms/100 ms/500 ms selectable *1
External input
Tuning /Transmission OFF selectable Short circuit current: 1 mA or less for NPN/2 mA or less for PNP For the applied voltage, see the wiring diagrams in the instruction manual. For the input times, see the time charts in the instruction manual. *2
Shock resistance
1,000 m/s 2 , 6 times in each of the X, Y, and Z directions
Relative humidity
35 to 85 % RH (No condensation)
Detecting distance
30 to 500 mm 1.18" to 19.69"
Min. spot diameter
Adjustable spot Approx. ø3.5 mm at 100 mm ø0.14" at 3.94" Approx. ø9 mm at 250 mm ø0.35" at 9.84" Approx. ø18 mm at 500 mm ø0.71" at 19.69"
Protection circuit
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection
Ambient temperature
-20 to +50 °C -4 to 122 °F (No freezing)
Current consumption
65 mA or less (without load) at 24 VDC
I/O / Control output
NPN open collector/PNP open collector selectable 30 VDC or less, 50 mA or less, remaining voltage: 2 V or less N.O./N.C. selectable *2
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
Power supply / Power voltage
10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS
Mutual interference reduction function
Up to 2 units when alternate frequencies set
Environmental resistance / Enclosure rating
IP65/IP67 (IEC60529)

Compatibility Information

Match LR-W500 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing LR-W500.

Maintenance Tips

Store LR-W500 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114