+86 13348028050
LP4K06105BW3 Schneider Electric LP4K06105BW3 - Front View | Vcocnc FANUC Parts

Schneider Electric LP4K06105BW3

Product information

SKU: LP4K06105BW3

Alternate: LP4K06105BW3

Brand
Schneider Electric
Part No.
LP4K06105BW3
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LP4K06105BW3 Product overview The Schneider Electric LP4K06105BW3 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 - Auxiliary contact composition: 1 NO - Auxiliary contacts type: Instantaneous 1 NO - Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Built-in bidirectional peak limiting diode suppressor - Connections - terminals: solder pins 0.001 in (0.035 mm)) - Contactor application: Motor control - Control circuit type: DC wide range - Control circuit voltage limits: Operational: 0.7...1.3 Uc (at <122 °F (50 °C)) Drop-out: >= 0.10 Uc (at <122 °F (50 °C)) - Device short name: LP4K - Electrical durability: 1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V - Heat dissipation: 1.8 W - Height: 2.3 in (58 mm) - Hold-in power consumption in W: 1.8 W 68 °F (20 °C) - Inrush power in W: 1.8 W 68 °F (20 °C)) - Insulation resistance: > 10 MOhm for signalling circuit - Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h - Mechanical durability: 30 Mcycles - Minimum switching current: 5 mA for signalling circuit - Minimum switching voltage: 17 V for signalling circuit - Motor power kW: 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4 - Mounting Support: Printed circuit boards - Operating time: 10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing - Overvoltage category: III - Poles description: 3P - Product or Component Type: Contactor - Range: TeSys - Rated breaking capacity: 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Utilisation category: AC-3 AC-3e AC-4 - [Icw] rated short-time withstand current: 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit - [Ie] rated operational current: 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit - [Ith] conventional free air thermal current: 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit - [Uc] control circuit voltage: 24 V DC - [Ue] rated operational voltage: Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz - [Ui] rated insulation voltage: Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LP4K06105BW3 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LP4K06105BW3
Brand
Schneider Electric
Part Number
LP4K06105BW3
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Height
2.3 in (58 mm)
Characteristic
Value(s)
Motor power kW
1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4
Operating time
10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing
Coil technology
Built-in bidirectional peak limiting diode suppressor
Heat dissipation
1.8 W
Mounting Support
Printed circuit boards
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Device short name
LP4K
Inrush power in W
1.8 W 68 °F (20 °C))
Poles description
3P
Control circuit type
DC wide range
Overvoltage category
III
Utilisation category
AC-3 AC-3e AC-4
Contactor application
Motor control
Electrical durability
1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V
Insulation resistance
> 10 MOhm for signalling circuit
Mechanical durability
30 Mcycles
Associated fuse rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate
3600 cyc/h
Auxiliary contacts type
Instantaneous 1 NO
Connections - terminals
solder pins 0.001 in (0.035 mm))
Rated breaking capacity
110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Product or Component Type
Contactor
Irms rated making capacity
110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
[Uc] control circuit voltage
24 V DC
Auxiliary contact composition
1 NO
[Ui] rated insulation voltage
Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Control circuit voltage limits
Operational: 0.7...1.3 Uc (at <122 °F (50 °C)) Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
Hold-in power consumption in W
1.8 W 68 °F (20 °C)
[Ie] rated operational current
6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
power pole contact composition
3 NO
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit
[Ith] conventional free air thermal current
20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit

Compatibility Information

Match LP4K06105BW3 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LP4K06105BW3.

Maintenance Tips

Store LP4K06105BW3 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options