Schneider Electric LP4K06105BW3
Product information
SKU: LP4K06105BW3
Alternate: LP4K06105BW3
Brand
Schneider Electric
Part No.
LP4K06105BW3
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LP4K06105BW3
Product overview
The Schneider Electric LP4K06105BW3 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Auxiliary contact composition: 1 NO
- Auxiliary contacts type: Instantaneous 1 NO
- Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
- Characteristic: Value(s)
- Coil technology: Built-in bidirectional peak limiting diode suppressor
- Connections - terminals: solder pins 0.001 in (0.035 mm))
- Contactor application: Motor control
- Control circuit type: DC wide range
- Control circuit voltage limits: Operational: 0.7...1.3 Uc (at <122 °F (50 °C)) Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
- Device short name: LP4K
- Electrical durability: 1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V
- Heat dissipation: 1.8 W
- Height: 2.3 in (58 mm)
- Hold-in power consumption in W: 1.8 W 68 °F (20 °C)
- Inrush power in W: 1.8 W 68 °F (20 °C))
- Insulation resistance: > 10 MOhm for signalling circuit
- Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- Maximum operating rate: 3600 cyc/h
- Mechanical durability: 30 Mcycles
- Minimum switching current: 5 mA for signalling circuit
- Minimum switching voltage: 17 V for signalling circuit
- Motor power kW: 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4
- Mounting Support: Printed circuit boards
- Operating time: 10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing
- Overvoltage category: III
- Poles description: 3P
- Product or Component Type: Contactor
- Range: TeSys
- Rated breaking capacity: 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Utilisation category: AC-3 AC-3e AC-4
- [Icw] rated short-time withstand current: 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit
- [Ie] rated operational current: 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
- [Ith] conventional free air thermal current: 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
- [Uc] control circuit voltage: 24 V DC
- [Ue] rated operational voltage: Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
- [Ui] rated insulation voltage: Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
- [Uimp] rated impulse withstand voltage: 8 kV
- power pole contact composition: 3 NO
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LP4K06105BW3 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LP4K06105BW3
- Brand
- Schneider Electric
- Part Number
- LP4K06105BW3
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Height
- 2.3 in (58 mm)
- Characteristic
- Value(s)
- Motor power kW
- 1.5 kW 220...230 V AC 50/60 Hz AC-3 2.2 kW 380...415 V AC 50/60 Hz AC-3 3 kW 440/690 V AC 50/60 Hz AC-3 1.5 kW 220...230 V AC 50/60 Hz AC-3e 2.2 kW 380...415 V AC 50/60 Hz AC-3e 3 kW 440/690 V AC 50/60 Hz AC-3e 1.5 kW 220...230 V AC 50/60 Hz AC-4 2.2 kW 380...415 V AC 50/60 Hz AC-4 3 kW 440/690 V AC 50/60 Hz AC-4
- Operating time
- 10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing
- Coil technology
- Built-in bidirectional peak limiting diode suppressor
- Heat dissipation
- 1.8 W
- Mounting Support
- Printed circuit boards
- Average impedance
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Device short name
- LP4K
- Inrush power in W
- 1.8 W 68 °F (20 °C))
- Poles description
- 3P
- Control circuit type
- DC wide range
- Overvoltage category
- III
- Utilisation category
- AC-3 AC-3e AC-4
- Contactor application
- Motor control
- Electrical durability
- 1.3 Mcycles 6 A AC-3 <= 440 V 1.3 Mcycles 6 A AC-3e <= 440 V 0.05 Mcycles 36 A AC-4 <= 440 V
- Insulation resistance
- > 10 MOhm for signalling circuit
- Mechanical durability
- 30 Mcycles
- Associated fuse rating
- 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Maximum operating rate
- 3600 cyc/h
- Auxiliary contacts type
- Instantaneous 1 NO
- Connections - terminals
- solder pins 0.001 in (0.035 mm))
- Rated breaking capacity
- 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Minimum switching current
- 5 mA for signalling circuit
- Minimum switching voltage
- 17 V for signalling circuit
- Product or Component Type
- Contactor
- Irms rated making capacity
- 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- [Uc] control circuit voltage
- 24 V DC
- Auxiliary contact composition
- 1 NO
- [Ui] rated insulation voltage
- Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
- Control circuit voltage limits
- Operational: 0.7...1.3 Uc (at <122 °F (50 °C)) Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
- Hold-in power consumption in W
- 1.8 W 68 °F (20 °C)
- [Ie] rated operational current
- 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
- [Ue] rated operational voltage
- Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
- power pole contact composition
- 3 NO
- [Uimp] rated impulse withstand voltage
- 8 kV
- [Icw] rated short-time withstand current
- 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit
- [Ith] conventional free air thermal current
- 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
Compatibility Information
Match LP4K06105BW3 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LP4K06105BW3.
Maintenance Tips
Store LP4K06105BW3 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LP4K06105BW3 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LP4K06105BW3 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LP4K06105BW3 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW