Product Description

Schneider Electric LP2K12015JD Product overview The Schneider Electric LP2K12015JD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 - Auxiliary contact composition: 1 NC - Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit - Characteristic: Value(s) - Connections - terminals: Solder pins - busbar cross section: 1.5 x 0.9 mm - Contactor application: Motor control Resistive load - Control circuit type: DC standard - Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C) - Device application: Control - Device presentation: Preassembled with reversing power busbar - Device short name: LP2K - Electrical durability: 0.3 Mcycles 20 A AC-1 at Ue <= 440 V 1.3 Mcycles 12 A AC-3 at Ue <= 440 V - Heat dissipation: 3 W - Hold-in power consumption in W: 3 W at 20 °C - Inrush power in W: 3 W (at 20 °C) - Interlocking type: Mechanical - Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947 144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h - Mechanical durability: 5 Mcycles - Motor power kW: 4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz - Mounting support: Plate Rail - Operating time: 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening - Overvoltage category: III - Poles description: 3P - Product certifications: CB Scheme CCC UL CSA EAC CE UKCA - Product or component type: Reversing contactor - Range: TeSys - Rated breaking capacity: 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Standards: EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 - Utilisation category: AC-4 AC-1 AC-3 - [Icw] rated short-time withstand current: 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 °C - >= 15 min for power circuit - [Ie] rated operational current: 20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit 12 A at <= 440 V AC AC-3 for power circuit - [Ith] conventional free air thermal current: 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit - [Uc] control circuit voltage: 12 V DC - [Ue] rated operational voltage: Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz - [Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO - product name: TeSys K Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LP2K12015JD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LP2K12015JD
Brand
Schneider Electric
Part Number
LP2K12015JD
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
product name
TeSys K
Characteristic
Value(s)
Motor power kW
4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz
Operating time
30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
Heat dissipation
3 W
Mounting support
Plate Rail
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Device short name
LP2K
Inrush power in W
3 W (at 20 °C)
Interlocking type
Mechanical
Poles description
3P
Device application
Control
Device presentation
Preassembled with reversing power busbar
Control circuit type
DC standard
Overvoltage category
III
Utilisation category
AC-4 AC-1 AC-3
Contactor application
Motor control Resistive load
Electrical durability
0.3 Mcycles 20 A AC-1 at Ue <= 440 V 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
Mechanical durability
5 Mcycles
Associated fuse rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate
3600 cyc/h
Product certifications
CB Scheme CCC UL CSA EAC CE UKCA
Connections - terminals
Solder pins - busbar cross section: 1.5 x 0.9 mm
Rated breaking capacity
110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Product or component type
Reversing contactor
Irms rated making capacity
110 A AC for signalling circuit conforming to IEC 60947 144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947
[Uc] control circuit voltage
12 V DC
Auxiliary contact composition
1 NC
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C)
Hold-in power consumption in W
3 W at 20 °C
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit 12 A at <= 440 V AC AC-3 for power circuit
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz Signalling circuit: <= 690 V AC 50/60 Hz
power pole contact composition
3 NO
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 °C - >= 15 min for power circuit
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit

Compatibility Information

Match LP2K12015JD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LP2K12015JD.

Maintenance Tips

Store LP2K12015JD dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options