Schneider Electric LP2K0601ND
Product information
SKU: LP2K0601ND
Alternate: LP2K0601ND
Brand
Schneider Electric
Part No.
LP2K0601ND
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LP2K0601ND
Product overview
The Schneider Electric LP2K0601ND is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Auxiliary contact composition: 1 NC
- Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
- Characteristic: Value(s)
- Connections - terminals: screw clamp terminals 1 0.002â¦0.006 in² (1.5â¦4 mm²)solid screw clamp terminals 1 0.001â¦0.006 in² (0.75â¦4 mm²)flexible without cable end screw clamp terminals 1 0.0005â¦0.004 in² (0.34â¦2.5 mm²)flexible with cable end screw clamp terminals 2 0.002â¦0.006 in² (1.5â¦4 mm²)solid screw clamp terminals 2 0.001â¦0.006 in² (0.75â¦4 mm²)flexible without cable end screw clamp terminals 2 0.0005â¦0.002 in² (0.34â¦1.5 mm²)flexible with cable end
- Contactor application: Motor control
- Control circuit type: DC standard
- Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
- Device Application: Control
- Device presentation: Preassembled with reversing power busbar
- Device short name: LP2K
- Electrical durability: 1.3 Mcycles 6 A AC-3 <= 440 V
- Hold-in power consumption in W: 3 W 68
- Inrush power in W: 3 W 68 °F (20 °C))
- Interlocking type: Mechanical
- Irms rated making capacity: 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- Maximum operating rate: 3600 cyc/h
- Mechanical durability: 5 Mcycles
- Motor power kW: 1.5 kW 220...230 V AC 50/60 Hz 2.2 kW 380...415 V AC 50/60 Hz 3 kW 440 V AC 50/60 Hz 3 kW 480 V AC 50/60 Hz 3 kW 500...600 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz
- Mounting Support: Plate Rail
- Operating time: 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
- Overvoltage category: III
- Poles description: 3P
- Product Certifications: CB Scheme CCC UL CSA EAC CE UKCA
- Product or Component Type: Reversing contactor
- Range: TeSys
- Rated breaking capacity: 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Standards: EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
- Tightening torque: 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals Philips No 2 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals flat à 6 mm
- Utilisation category: AC-4 AC-3
- [Icw] rated short-time withstand current: 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit
- [Ie] rated operational current: 6 A at <= 440 V AC AC-3 for power circuit
- [Ith] conventional free air thermal current: 20 A (at 122 °F (50 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
- [Uc] control circuit voltage: 60 V DC
- [Ue] rated operational voltage: Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
- [Ui] rated insulation voltage: Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
- [Uimp] rated impulse withstand voltage: 8 kV
- power pole contact composition: 3 NO
- product name: TeSys K
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LP2K0601ND with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LP2K0601ND
- Brand
- Schneider Electric
- Part Number
- LP2K0601ND
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Standards
- EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
- product name
- TeSys K
- Characteristic
- Value(s)
- Motor power kW
- 1.5 kW 220...230 V AC 50/60 Hz 2.2 kW 380...415 V AC 50/60 Hz 3 kW 440 V AC 50/60 Hz 3 kW 480 V AC 50/60 Hz 3 kW 500...600 V AC 50/60 Hz 3 kW 660...690 V AC 50/60 Hz
- Operating time
- 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening
- Mounting Support
- Plate Rail
- Average impedance
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Device short name
- LP2K
- Inrush power in W
- 3 W 68 °F (20 °C))
- Interlocking type
- Mechanical
- Poles description
- 3P
- Tightening torque
- 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals Philips No 2 7.08â¦11.5 lbf.in (0.8â¦1.3 N.m) screw clamp terminals flat à 6 mm
- Device Application
- Control
- Device presentation
- Preassembled with reversing power busbar
- Control circuit type
- DC standard
- Overvoltage category
- III
- Utilisation category
- AC-4 AC-3
- Contactor application
- Motor control
- Electrical durability
- 1.3 Mcycles 6 A AC-3 <= 440 V
- Mechanical durability
- 5 Mcycles
- Associated fuse rating
- 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Maximum operating rate
- 3600 cyc/h
- Product Certifications
- CB Scheme CCC UL CSA EAC CE UKCA
- Connections - terminals
- screw clamp terminals 1 0.002â¦0.006 in² (1.5â¦4 mm²)solid screw clamp terminals 1 0.001â¦0.006 in² (0.75â¦4 mm²)flexible without cable end screw clamp terminals 1 0.0005â¦0.004 in² (0.34â¦2.5 mm²)flexible with cable end screw clamp terminals 2 0.002â¦0.006 in² (1.5â¦4 mm²)solid screw clamp terminals 2 0.001â¦0.006 in² (0.75â¦4 mm²)flexible without cable end screw clamp terminals 2 0.0005â¦0.002 in² (0.34â¦1.5 mm²)flexible with cable end
- Rated breaking capacity
- 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Product or Component Type
- Reversing contactor
- Irms rated making capacity
- 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- [Uc] control circuit voltage
- 60 V DC
- Auxiliary contact composition
- 1 NC
- [Ui] rated insulation voltage
- Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
- Control circuit voltage limits
- Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
- Hold-in power consumption in W
- 3 W 68
- [Ie] rated operational current
- 6 A at <= 440 V AC AC-3 for power circuit
- [Ue] rated operational voltage
- Power circuit 690 V AC 50/60 Hz Signalling circuit <= 690 V AC 50/60 Hz
- power pole contact composition
- 3 NO
- [Uimp] rated impulse withstand voltage
- 8 kV
- [Icw] rated short-time withstand current
- 90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit
- [Ith] conventional free air thermal current
- 20 A (at 122 °F (50 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit
Compatibility Information
Match LP2K0601ND against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LP2K0601ND.
Maintenance Tips
Store LP2K0601ND dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LP2K0601ND is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LP2K0601ND is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LP2K0601ND against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW