+86 13348028050
LP1K09008GD Schneider Electric LP1K09008GD - Front View | Vcocnc FANUC Parts

Schneider Electric LP1K09008GD

Product information

SKU: LP1K09008GD

Alternate: LP1K09008GD

Brand
Schneider Electric
Part No.
LP1K09008GD
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LP1K09008GD Product overview The Schneider Electric LP1K09008GD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient air temperature for operation: -13…122 °F (-25…50 °C) - Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit - Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit - Characteristic: Value(s) - Contactor application: Resistive load - Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C)) - Depth: 2.2 in (57 mm) - Device short name: LP1K - Flame retardance: V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 - Height: 2.3 in (58 mm) - Hold-in power consumption in W: 3 W 68 °F (20 °C) - Inrush power in W: 3 W 68 °F (20 °C)) - Irms rated making capacity: 110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h - Mechanical durability: 10 Mcycles - Mounting Support: Rail Plate - Operating time: 30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing - Overvoltage category: III - Pole contact composition: 2 NO + 2 NC - Poles description: 4P - Product Weight: 0.496 lb(US) (0.225 kg) - Product or Component Type: Contactor - Range: TeSys - Range of Product: TeSys K - Rated breaking capacity: 110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Standards: EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 - Tightening torque: 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm - Utilisation category: AC-1 - Width: 1.8 in (45 mm) - [Ie] rated operational current: 20 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 20 A (at 122 °F (50 °C)) for power circuit - [Ue] rated operational voltage: Power circuit 690 V AC 50/60 Hz - [Ui] rated insulation voltage: Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14 - [Uimp] rated impulse withstand voltage: 8 kV Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LP1K09008GD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LP1K09008GD
Brand
Schneider Electric
Part Number
LP1K09008GD
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
2.2 in (57 mm)
Range
TeSys
Width
1.8 in (45 mm)
Height
2.3 in (58 mm)
Standards
EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1
Characteristic
Value(s)
Operating time
30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing
Product Weight
0.496 lb(US) (0.225 kg)
Flame retardance
V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
Mounting Support
Rail Plate
Range of Product
TeSys K
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Device short name
LP1K
Inrush power in W
3 W 68 °F (20 °C))
Poles description
4P
Tightening torque
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Mechanical durability
10 Mcycles
Associated fuse rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit
Maximum operating rate
3600 cyc/h
Rated breaking capacity
110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
Pole contact composition
2 NO + 2 NC
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product or Component Type
Contactor
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947
[Ui] rated insulation voltage
Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: 0.1...0.75 Uc (at <122 °F (50 °C))
Hold-in power consumption in W
3 W 68 °F (20 °C)
[Ie] rated operational current
20 A (at <122 °F (50 °C)) at <= 440 V AC AC-1 for power circuit 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit 690 V AC 50/60 Hz
Ambient air temperature for operation
-13…122 °F (-25…50 °C)
[Uimp] rated impulse withstand voltage
8 kV
[Ith] conventional free air thermal current
20 A (at 122 °F (50 °C)) for power circuit

Compatibility Information

Match LP1K09008GD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LP1K09008GD.

Maintenance Tips

Store LP1K09008GD dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options