+86 13348028050
LP1D65008GD Schneider Electric LP1D65008GD - Front View | Vcocnc FANUC Parts

Schneider Electric LP1D65008GD

Product information

SKU: LP1D65008GD

Alternate: LP1D65008GD

Brand
Schneider Electric
Part No.
LP1D65008GD
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LP1D65008GD Product overview The Schneider Electric LP1D65008GD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit - Average impedance: 1.5 mOhm - Ith 80 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Built-in bidirectional peak limiting diode suppressor - Compatibility code: LP1D - Connections - terminals: Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid - Contactor application: Resistive load - Control circuit type: DC DC standard - Control circuit voltage limits: 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational DC 1...1.1 Uc (131…158 °F (55…70 °C)):operational DC - Device short name: LP1D - Electrical durability: 1.4 Mcycles 80 A AC-1 <= 440 V - Hold-in power consumption in W: 22 W 68 °F (20 °C) - Inrush power in W: 22 W 68 °F (20 °C)) - Irms rated making capacity: 1000 A at 440 V for power circuit conforming to IEC 60947 - Mechanical durability: 6 Mcycles - Operating time: 4...19 ms opening 12...26 ms closing - Overvoltage category: III - Pole contact composition: 2 NO + 2 NC - Poles description: 4P - Power dissipation per pole: 9.6 W AC-1 - Product or Component Type: Contactor - Protective cover: Without - Range: TeSys - Range of Product: TeSys Deca - Rated breaking capacity: 1000 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Tightening torque: Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm) - Time constant: 75 ms - Utilisation category: AC-1 - [Icw] rated short-time withstand current: 110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit - [Ie] rated operational current: 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 80 A (at 140 °F (60 °C)) for power circuit - [Uc] control circuit voltage: 125 V DC - [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC - [Ui] rated insulation voltage: Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947 - pollution degree: 3 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LP1D65008GD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LP1D65008GD
Brand
Schneider Electric
Part Number
LP1D65008GD
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Time constant
75 ms
Characteristic
Value(s)
Operating time
4...19 ms opening 12...26 ms closing
Coil technology
Built-in bidirectional peak limiting diode suppressor
Protective cover
Without
Range of Product
TeSys Deca
pollution degree
3
Average impedance
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Device short name
LP1D
Inrush power in W
22 W 68 °F (20 °C))
Poles description
4P
Tightening torque
Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002…0.04 in² (1…25 mm²) hexagonal 0.2 in (4 mm)
Compatibility code
LP1D
Control circuit type
DC DC standard
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Electrical durability
1.4 Mcycles 80 A AC-1 <= 440 V
Mechanical durability
6 Mcycles
Associated fuse rating
125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit
Connections - terminals
Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.002…0.05 in² (1…35 mm²) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.002…0.04 in² (1…25 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid
Rated breaking capacity
1000 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition
2 NO + 2 NC
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product or Component Type
Contactor
Irms rated making capacity
1000 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
9.6 W AC-1
[Uc] control circuit voltage
125 V DC
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL
Control circuit voltage limits
0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational DC 1...1.1 Uc (131…158 °F (55…70 °C)):operational DC
Hold-in power consumption in W
22 W 68 °F (20 °C)
[Ie] rated operational current
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
[Icw] rated short-time withstand current
110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit
[Ith] conventional free air thermal current
80 A (at 140 °F (60 °C)) for power circuit

Compatibility Information

Match LP1D65008GD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LP1D65008GD.

Maintenance Tips

Store LP1D65008GD dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options