+86 13348028050
LC2F1154 Schneider Electric LC2F1154 - Front View | Vcocnc FANUC Parts

Schneider Electric LC2F1154

Product information

$1,756.80 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LC2F1154

Alternate: LC2F1154

Brand
Schneider Electric
Part No.
LC2F1154
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC2F1154 Product overview The Schneider Electric LC2F1154 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A aM at <= 440 V 200 A gG at <= 440 V - Auxiliary contact composition: 1 NO - Average impedance: 0.37 mOhm - Ith 200 A 50 Hz - Characteristic: Value(s) - Connections - terminals: Power circuit connector 1 0.1 in² (95 mm²) Power circuit lugs-ring terminals 1 0.1 in² (95 mm²) Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 20 x 3 mm - Contactor application: Resistive load - Device presentation: Preassembled with reversing power busbar - Device short name: LC2F - Interlocking type: Mechanical - Irms rated making capacity: 1150 A AC conforming to IEC 60947-4-1 - Mounting Support: Plate - Overvoltage category: III - Poles description: 4P - Power dissipation per pole: 15 W AC-1 - Product Certifications: CCC RMRoS UL RINA CB ABS LROS (Lloyds register of shipping) CSA DNV UKCA - Product or Component Type: Changeover contactor - Range: TeSys - Rated breaking capacity: 920 A conforming to IEC 60947-4-1 - Standards: EN 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 - Tightening torque: Power circuit 88.5 lbf.in (10 N.m) Control circuit 10.6 lbf.in (1.2 N.m) - Utilisation category: AC-1 - [Icw] rated short-time withstand current: 1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min - [Ie] rated operational current: 200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 - [Ith] conventional free air thermal current: 200 A (at 104 °F (40 °C)) - [Ue] rated operational voltage: <= 1000 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V IEC 60947-4-1 1500 V VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 4 NO - product name: TeSys F Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC2F1154 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC2F1154
Brand
Schneider Electric
Part Number
LC2F1154
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Standards
EN 60947-1 IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-1
product name
TeSys F
Characteristic
Value(s)
Mounting Support
Plate
Average impedance
0.37 mOhm - Ith 200 A 50 Hz
Device short name
LC2F
Interlocking type
Mechanical
Poles description
4P
Tightening torque
Power circuit 88.5 lbf.in (10 N.m) Control circuit 10.6 lbf.in (1.2 N.m)
Device presentation
Preassembled with reversing power busbar
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Associated fuse rating
125 A aM at <= 440 V 200 A gG at <= 440 V
Product Certifications
CCC RMRoS UL RINA CB ABS LROS (Lloyds register of shipping) CSA DNV UKCA
Connections - terminals
Power circuit connector 1 0.1 in² (95 mm²) Power circuit lugs-ring terminals 1 0.1 in² (95 mm²) Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 20 x 3 mm
Rated breaking capacity
920 A conforming to IEC 60947-4-1
Product or Component Type
Changeover contactor
Irms rated making capacity
1150 A AC conforming to IEC 60947-4-1
Power dissipation per pole
15 W AC-1
Auxiliary contact composition
1 NO
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
[Ie] rated operational current
200 A (at <104 °F (40 °C)) at <= 440 V AC AC-1
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
power pole contact composition
4 NO
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min
[Ith] conventional free air thermal current
200 A (at 104 °F (40 °C))

Compatibility Information

Match LC2F1154 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC2F1154.

Maintenance Tips

Store LC2F1154 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options