+86 13348028050
LC2DT32M7 Schneider Electric LC2DT32M7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC2DT32M7

Product information

$668.25 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LC2DT32M7

Alternate: LC2DT32M7

Brand
Schneider Electric
Part No.
LC2DT32M7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC2DT32M7 Product overview The Schneider Electric LC2DT32M7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit - Auxiliary contact composition: 1 NO + 1 NC - Average impedance: 2.5 mOhm - Ith 32 A 50 Hz for power circuit - Characteristic: Value(s) - Connections - terminals: Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid Power circuit connector 1 0.004…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 2 0.004…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 1 0.004…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 2 0.004…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 1 0.004…0.02 in² (2.5…16 mm²)solid Power circuit connector 2 0.004…0.02 in² (2.5…16 mm²)solid - Contactor application: Resistive load - Control circuit type: AC 50/60 Hz - Device presentation: Preassembled, with prewired power connections - Device short name: LC2D - Electrical durability: 1 Mcycles 32 A AC-1 <= 440 V - Front cover: With - Interlocking type: Mechanical - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h 140 °F (60 °C) - Mechanical durability: 15 Mcycles - Mounting Support: Rail Plate - Operating time: 12...22 ms closing 4...19 ms opening - Overvoltage category: III - Poles description: 4P - Power dissipation per pole: 2.5 W AC-1 - Product Certifications: BV RINA CCC GOST CSA DNV UL LROS (Lloyds register of shipping) GL - Product or Component Type: Changeover contactor - Range: TeSys - Rated breaking capacity: 300 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Standards: CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 - Tightening torque: Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) connector flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) connector Philips No 2 - Utilisation category: AC-1 AC-3 AC-3e AC-4 - [Icw] rated short-time withstand current: 40 A 104 °F (40 °C) - 10 min for power circuit 84 A 104 °F (40 °C) - 1 min for power circuit 145 A 104 °F (40 °C) - 10 s for power circuit 240 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit - [Ie] rated operational current: 32 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 10 A (at 140 °F (60 °C)) for signalling circuit 32 A (at 140 °F (60 °C)) for power circuit - [Uc] control circuit voltage: 220 V AC 50/60 Hz - [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC - [Ui] rated insulation voltage: Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947 - power pole contact composition: 4 NO - product name: TeSys Deca Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC2DT32M7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC2DT32M7
Brand
Schneider Electric
Part Number
LC2DT32M7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Standards
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Front cover
With
product name
TeSys Deca
Characteristic
Value(s)
Operating time
12...22 ms closing 4...19 ms opening
Mounting Support
Rail Plate
Average impedance
2.5 mOhm - Ith 32 A 50 Hz for power circuit
Device short name
LC2D
Interlocking type
Mechanical
Poles description
4P
Tightening torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 15.05 lbf.in (1.7 N.m) connector flat Ø 6 mm Power circuit 15.05 lbf.in (1.7 N.m) connector Philips No 2
Device presentation
Preassembled, with prewired power connections
Control circuit type
AC 50/60 Hz
Overvoltage category
III
Utilisation category
AC-1 AC-3 AC-3e AC-4
Contactor application
Resistive load
Electrical durability
1 Mcycles 32 A AC-1 <= 440 V
Mechanical durability
15 Mcycles
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 50 A gG at <= 690 V coordination type 1 for power circuit 35 A gG at <= 690 V coordination type 2 for power circuit
Maximum operating rate
3600 cyc/h 140 °F (60 °C)
Product Certifications
BV RINA CCC GOST CSA DNV UL LROS (Lloyds register of shipping) GL
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid Power circuit connector 1 0.004…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 2 0.004…0.02 in² (2.5…10 mm²)flexible without cable end Power circuit connector 1 0.004…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 2 0.004…0.02 in² (2.5…10 mm²)flexible with cable end Power circuit connector 1 0.004…0.02 in² (2.5…16 mm²)solid Power circuit connector 2 0.004…0.02 in² (2.5…16 mm²)solid
Rated breaking capacity
300 A at 440 V for power circuit conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product or Component Type
Changeover contactor
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 300 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
2.5 W AC-1
[Uc] control circuit voltage
220 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
[Ie] rated operational current
32 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
power pole contact composition
4 NO
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
[Icw] rated short-time withstand current
40 A 104 °F (40 °C) - 10 min for power circuit 84 A 104 °F (40 °C) - 1 min for power circuit 145 A 104 °F (40 °C) - 10 s for power circuit 240 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for signalling circuit 32 A (at 140 °F (60 °C)) for power circuit

Compatibility Information

Match LC2DT32M7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC2DT32M7.

Maintenance Tips

Store LC2DT32M7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options