+86 13348028050
LC2D65A3F7 Schneider Electric LC2D65A3F7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC2D65A3F7

Product information

SKU: LC2D65A3F7

Alternate: LC2D65A3F7

Brand
Schneider Electric
Part No.
LC2D65A3F7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC2D65A3F7 Product overview The Schneider Electric LC2D65A3F7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit - Auxiliary contact composition: 1 NO + 1 NC - Average impedance: 1.5 mOhm - Ith 80 A 50 Hz for power circuit - Characteristic: Value(s) - Connections - terminals: Control circuit spring terminals 1 0.004 in² (2.5 mm²)flexible without cable end Control circuit spring terminals 2 0.004 in² (2.5 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)solid Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)solid - Contactor application: Motor control Resistive load - Control circuit type: AC 50/60 Hz - Device presentation: Preassembled with reversing power busbar - Device short name: LC2D - Electrical durability: 1.45 Mcycles 65 A AC-3 <= 440 V 1.4 Mcycles 80 A AC-1 <= 440 V - Front cover: With - Interlocking type: Mechanical - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 - Motor power kW: 18.5 kW at 220...230 V AC 50 Hz 30 kW at 380...400 V AC 50 Hz 37 kW at 415...440 V AC 50 Hz 37 kW at 500 V AC 50 Hz 37 kW at 660...690 V AC 50 Hz - Mounting Support: Rail Plate - Operating time: 4...19 ms opening 12...26 ms closing - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 9.6 W AC-1 6.3 W AC-3 - Product Certifications: CSA GOST UL CCC - Product or Component Type: Reversing contactor - Range: TeSys - Rated breaking capacity: 1000 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 - Standards: CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 - Tightening torque: Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm) Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.004…0.04 in² (2.5…25 mm²) hexagonal 0.2 in (4 mm) - Utilisation category: AC-1 AC-3 - [Icw] rated short-time withstand current: 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit 110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit - [Ie] rated operational current: 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit - [Ith] conventional free air thermal current: 10 A (at 140 °F (60 °C)) for signalling circuit 80 A (at 140 °F (60 °C)) for power circuit - [Uc] control circuit voltage: 110 V AC 50/60 Hz - [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC - [Ui] rated insulation voltage: Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947 - motor power HP (UL / CSA): 40 hp at 460/480 V AC 60 Hz for 3 phase motors 5 hp at 115 V AC 60 Hz for 1 phase motors 10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors - power pole contact composition: 3 NO - product name: TeSys Deca Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC2D65A3F7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC2D65A3F7
Brand
Schneider Electric
Part Number
LC2D65A3F7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Front cover
With
product name
TeSys Deca
Characteristic
Value(s)
Motor power kW
18.5 kW at 220...230 V AC 50 Hz 30 kW at 380...400 V AC 50 Hz 37 kW at 415...440 V AC 50 Hz 37 kW at 500 V AC 50 Hz 37 kW at 660...690 V AC 50 Hz
Operating time
4...19 ms opening 12...26 ms closing
Mounting Support
Rail Plate
Average impedance
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Device short name
LC2D
Interlocking type
Mechanical
Poles description
3P
Tightening torque
Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04…0.05 in² (25…35 mm²) hexagonal 0.2 in (4 mm) Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.004…0.04 in² (2.5…25 mm²) hexagonal 0.2 in (4 mm)
Device presentation
Preassembled with reversing power busbar
Control circuit type
AC 50/60 Hz
Overvoltage category
III
Utilisation category
AC-1 AC-3
Contactor application
Motor control Resistive load
Electrical durability
1.45 Mcycles 65 A AC-3 <= 440 V 1.4 Mcycles 80 A AC-1 <= 440 V
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit
Product Certifications
CSA GOST UL CCC
Connections - terminals
Control circuit spring terminals 1 0.004 in² (2.5 mm²)flexible without cable end Control circuit spring terminals 2 0.004 in² (2.5 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible without cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)flexible with cable end Power circuit EverLink BTR screw connectors 1 0.002…0.05 in² (1…35 mm²)solid Power circuit EverLink BTR screw connectors 2 0.002…0.04 in² (1…25 mm²)solid
Rated breaking capacity
1000 A at 440 V for power circuit conforming to IEC 60947
Safety reliability level
B10d = 1369863
Product or Component Type
Reversing contactor
motor power HP (UL / CSA)
40 hp at 460/480 V AC 60 Hz for 3 phase motors 5 hp at 115 V AC 60 Hz for 1 phase motors 10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
9.6 W AC-1 6.3 W AC-3
[Uc] control circuit voltage
110 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Ui] rated insulation voltage
Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
[Ie] rated operational current
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
power pole contact composition
3 NO
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
[Icw] rated short-time withstand current
520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit 110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current
10 A (at 140 °F (60 °C)) for signalling circuit 80 A (at 140 °F (60 °C)) for power circuit

Compatibility Information

Match LC2D65A3F7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC2D65A3F7.

Maintenance Tips

Store LC2D65A3F7 dry and dust-free in its packaging until installation.