- Associated fuse rating: 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1
- Auxiliary contact composition: 1 NO + 1 NC
- Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Characteristic: Value(s)
- Coil technology: Without built-in suppressor module
- Connections - terminals: Control circuit lugs-ring terminals 0.3 in (8 mm)) Power circuit lugs-ring terminals 0.3 in (8 mm))
- Contactor application: Motor control Resistive load
- Control circuit type: AC 50/60 Hz
- Device presentation: Preassembled with reversing power busbar
- Device short name: LC2D
- Electrical durability: 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V
- Front cover: With
- Interlocking type: Mechanical
- Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Maximum operating rate: 3600 cyc/h 140 °F (60 °C)
- Mechanical durability: 15 Mcycles
- Motor power kW: 2.2 kW at 220...230 V AC 50 Hz 4 kW at 380...400 V AC 50 Hz 4 kW at 415...440 V AC 50 Hz 5.5 kW at 500 V AC 50 Hz 5.5 kW at 660...690 V AC 50 Hz
- Mounting Support: Rail Plate
- Operating time: 12...22 ms closing 4...19 ms opening
- Overvoltage category: III
- Poles description: 3P
- Power dissipation per pole: 0.2 W AC-3 1.56 W AC-1
- Product Certifications: BV RINA GL LROS (Lloyds register of shipping) GOST DNV CSA UL CCC
- Product or Component Type: Reversing contactor
- Range: TeSys
- Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Standards: CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Tightening torque: Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat à 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat à 8 mm M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5
- Utilisation category: AC-1 AC-3
- [Icw] rated short-time withstand current: 30 A 104 °F (40 °C) - 10 min for power circuit 61 A 104 °F (40 °C) - 1 min for power circuit 105 A 104 °F (40 °C) - 10 s for power circuit 210 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
- [Ie] rated operational current: 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
- [Ith] conventional free air thermal current: 10 A (at 140 °F (60 °C)) for signalling circuit 25 A (at 140 °F (60 °C)) for power circuit
- [Uc] control circuit voltage: 110 V AC 50/60 Hz
- [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- [Ui] rated insulation voltage: Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- [Uimp] rated impulse withstand voltage: 6 kV IEC 60947
- motor power HP (UL / CSA): 0.5 hp at 115 V AC 60 Hz for 1 phase motors 1 hp at 230/240 V AC 60 Hz for 1 phase motors 2 hp at 200/208 V AC 60 Hz for 3 phase motors 2 hp at 230/240 V AC 60 Hz for 3 phase motors 5 hp at 460/480 V AC 60 Hz for 3 phase motors 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors
- power pole contact composition: 3 NO
- product name: TeSys Deca
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LC2D096F7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LC2D096F7
- Brand
- Schneider Electric
- Part Number
- LC2D096F7
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Standards
- CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
- Front cover
- With
- product name
- TeSys Deca
- Characteristic
- Value(s)
- Motor power kW
- 2.2 kW at 220...230 V AC 50 Hz 4 kW at 380...400 V AC 50 Hz 4 kW at 415...440 V AC 50 Hz 5.5 kW at 500 V AC 50 Hz 5.5 kW at 660...690 V AC 50 Hz
- Operating time
- 12...22 ms closing 4...19 ms opening
- Coil technology
- Without built-in suppressor module
- Mounting Support
- Rail Plate
- Average impedance
- 2.5 mOhm - Ith 25 A 50 Hz for power circuit
- Device short name
- LC2D
- Interlocking type
- Mechanical
- Poles description
- 3P
- Tightening torque
- Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat à 6 mm M3.5 Control circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals flat à 8 mm M3.5 Power circuit 15.05 lbf.in (1.7 N.m) lugs-ring terminals Philips No 2 M3.5
- Device presentation
- Preassembled with reversing power busbar
- Control circuit type
- AC 50/60 Hz
- Overvoltage category
- III
- Utilisation category
- AC-1 AC-3
- Contactor application
- Motor control Resistive load
- Electrical durability
- 0.6 Mcycles 25 A AC-1 <= 440 V 2 Mcycles 9 A AC-3 <= 440 V
- Mechanical durability
- 15 Mcycles
- Associated fuse rating
- 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1
- Maximum operating rate
- 3600 cyc/h 140 °F (60 °C)
- Product Certifications
- BV RINA GL LROS (Lloyds register of shipping) GOST DNV CSA UL CCC
- Connections - terminals
- Control circuit lugs-ring terminals 0.3 in (8 mm)) Power circuit lugs-ring terminals 0.3 in (8 mm))
- Rated breaking capacity
- 250 A at 440 V for power circuit conforming to IEC 60947
- Safety reliability level
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Product or Component Type
- Reversing contactor
- motor power HP (UL / CSA)
- 0.5 hp at 115 V AC 60 Hz for 1 phase motors 1 hp at 230/240 V AC 60 Hz for 1 phase motors 2 hp at 200/208 V AC 60 Hz for 3 phase motors 2 hp at 230/240 V AC 60 Hz for 3 phase motors 5 hp at 460/480 V AC 60 Hz for 3 phase motors 7.5 hp at 575/600 V AC 60 Hz for 3 phase motors
- Irms rated making capacity
- 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Power dissipation per pole
- 0.2 W AC-3 1.56 W AC-1
- [Uc] control circuit voltage
- 110 V AC 50/60 Hz
- Auxiliary contact composition
- 1 NO + 1 NC
- [Ui] rated insulation voltage
- Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL
- [Ie] rated operational current
- 9 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 25 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
- [Ue] rated operational voltage
- Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
- power pole contact composition
- 3 NO
- [Uimp] rated impulse withstand voltage
- 6 kV IEC 60947
- [Icw] rated short-time withstand current
- 30 A 104 °F (40 °C) - 10 min for power circuit 61 A 104 °F (40 °C) - 1 min for power circuit 105 A 104 °F (40 °C) - 10 s for power circuit 210 A 104 °F (40 °C) - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
- [Ith] conventional free air thermal current
- 10 A (at 140 °F (60 °C)) for signalling circuit 25 A (at 140 °F (60 °C)) for power circuit
Compatibility Information
Match LC2D096F7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LC2D096F7.
Maintenance Tips
Store LC2D096F7 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LC2D096F7 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LC2D096F7 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LC2D096F7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW