+86 13348028050
LC2D093P7 Schneider Electric LC2D093P7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC2D093P7

Product information

SKU: LC2D093P7

Alternate: LC2D093P7

Brand
Schneider Electric
Part No.
LC2D093P7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC2D093P7 Product overview The Schneider Electric LC2D093P7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1 - Auxiliary contact composition: 1 NO + 1 NC - Average impedance: 2.5 mOhm - Ith 16 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Without built-in suppressor module - Connections - terminals: Power circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end Control circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end Control circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end - Contactor application: Resistive load Motor control - Control circuit type: AC at 50/60 Hz - Control circuit voltage limits: 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz - Device presentation: Preassembled with reversing power busbar - Device short name: LC2D - Electrical durability: 0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V - Front cover: With - Interlocking type: Mechanical - Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 - Maximum operating rate: 3600 cyc/h 60 °C - Mechanical durability: 15 Mcycles - Motor power kW: 2.2 kW at 220...230 V AC 50 Hz 4 kW at 380...400 V AC 50 Hz 4 kW at 415...440 V AC 50 Hz 5.5 kW at 500 V AC 50 Hz 5.5 kW at 660...690 V AC 50 Hz - Mounting support: Rail Plate - Operating time: 12...22 ms closing 4...19 ms opening - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 0.2 W AC-3 1.56 W AC-1 - Product certifications: GL UL DNV LROS (Lloyds register of shipping) RINA CCC GOST BV CSA - Product or component type: Reversing contactor - Range: TeSys - Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Standards: CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 - Utilisation category: AC-3 AC-1 - [Icw] rated short-time withstand current: 30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit - [Ie] rated operational current: 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 16 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit - [Uc] control circuit voltage: 230 V AC 50/60 Hz - [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC - [Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified - [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947 - motor power HP (UL / CSA): 0.5 hp at 115 V AC 60 Hz for 1 phase motors 1 hp at 230/240 V AC 60 Hz for 1 phase motors 2 hp at 200/208 V AC 60 Hz for 3 phases motors 2 hp at 230/240 V AC 60 Hz for 3 phases motors 5 hp at 460/480 V AC 60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 60 Hz for 3 phases motors - power pole contact composition: 3 NO - product name: TeSys Deca Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC2D093P7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC2D093P7
Brand
Schneider Electric
Part Number
LC2D093P7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
Front cover
With
product name
TeSys Deca
Characteristic
Value(s)
Motor power kW
2.2 kW at 220...230 V AC 50 Hz 4 kW at 380...400 V AC 50 Hz 4 kW at 415...440 V AC 50 Hz 5.5 kW at 500 V AC 50 Hz 5.5 kW at 660...690 V AC 50 Hz
Operating time
12...22 ms closing 4...19 ms opening
Coil technology
Without built-in suppressor module
Mounting support
Rail Plate
Average impedance
2.5 mOhm - Ith 16 A 50 Hz for power circuit
Device short name
LC2D
Interlocking type
Mechanical
Poles description
3P
Device presentation
Preassembled with reversing power busbar
Control circuit type
AC at 50/60 Hz
Overvoltage category
III
Utilisation category
AC-3 AC-1
Contactor application
Resistive load Motor control
Electrical durability
0.6 Mcycles 25 A AC-1 at Ue <= 440 V 2 Mcycles 9 A AC-3 at Ue <= 440 V
Mechanical durability
15 Mcycles
Associated fuse rating
25 A gG at <= 690 V coordination type 1 for power circuit 20 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1
Maximum operating rate
3600 cyc/h 60 °C
Product certifications
GL UL DNV LROS (Lloyds register of shipping) RINA CCC GOST BV CSA
Connections - terminals
Power circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end Control circuit: spring terminals 1 cable(s) 2.5 mm²flexible without cable end Control circuit: spring terminals 2 cable(s) 2.5 mm²flexible without cable end
Rated breaking capacity
250 A at 440 V for power circuit conforming to IEC 60947
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Product or component type
Reversing contactor
motor power HP (UL / CSA)
0.5 hp at 115 V AC 60 Hz for 1 phase motors 1 hp at 230/240 V AC 60 Hz for 1 phase motors 2 hp at 200/208 V AC 60 Hz for 3 phases motors 2 hp at 230/240 V AC 60 Hz for 3 phases motors 5 hp at 460/480 V AC 60 Hz for 3 phases motors 7.5 hp at 575/600 V AC 60 Hz for 3 phases motors
Irms rated making capacity
250 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
Power dissipation per pole
0.2 W AC-3 1.56 W AC-1
[Uc] control circuit voltage
230 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
Control circuit voltage limits
0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
[Ie] rated operational current
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC
power pole contact composition
3 NO
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
[Icw] rated short-time withstand current
30 A 40 °C - 10 min for power circuit 61 A 40 °C - 1 min for power circuit 105 A 40 °C - 10 s for power circuit 210 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current
16 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit

Compatibility Information

Match LC2D093P7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC2D093P7.

Maintenance Tips

Store LC2D093P7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options