Schneider Electric LC1SK0600G7
Product information
SKU: LC1SK0600G7
Alternate: LC1SK0600G7
Brand
Schneider Electric
Part No.
LC1SK0600G7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LC1SK0600G7
Product overview
The Schneider Electric LC1SK0600G7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 16 A gI at <= 440 V for power circuit conforming to IEC 60947
- Average impedance: 4 mOhm - Ith 12 A 50 Hz
- Characteristic: Value(s)
- Connections - terminals: Power circuit connector 1 0.0005â¦0.009 in² (0.35â¦6 mm²)flexible with cable end Power circuit connector 1 0.0008â¦0.009 in² (0.5â¦6 mm²)flexible without cable end Power circuit connector 1 0.002â¦0.009 in² (1.5â¦6 mm²)solid Power circuit connector 2 0.0005â¦0.002 in² (0.35â¦1.5 mm²)flexible with cable end Power circuit connector 2 0.0005â¦0.004 in² (0.35â¦2.5 mm²)flexible without cable end Power circuit connector 2 0.002â¦0.006 in² (1.5â¦4 mm²)solid
- Contactor application: Motor control Resistive load
- Control circuit type: AC 50/60 Hz
- Control circuit voltage limits: Operational: 0.85...1.1 Uc (at <122 °F (50 °C)) Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C))
- Device short name: LC1SK
- Heat dissipation: 1.4 W 50/60 Hz
- Hold-in power consumption in VA: 4.2 VA (at 68 °F (20 °C))
- Inrush power in VA: 16 VA (at 68 °F (20 °C))
- Irms rated making capacity: 66 A at 690 V AC conforming to IEC 60947 66 A at 690 V AC conforming to NF C 63-110
- Maximum operating rate: 1200 cyc/h
- Mechanical durability: 10 Mcycles
- Mounting Support: Rail
- Operating time: 6...8 ms coil de-energisation and NO opening 7...14 ms coil energisation and NO closing
- Pole contact composition: 2 NO
- Product Certifications: CB Scheme CE UKCA EAC cULus
- Product or Component Type: Mini contactor
- Range: TeSys
- Rated breaking capacity: 52 A at <= 400 V for power circuit conforming to NF C 63-110 52 A at <= 400 V for power circuit conforming to IEC 60947
- Standards: EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
- Tightening torque: 7.08 lbf.in (0.8 N.m) connector pozidriv No 1
- Utilisation category: AC-1 AC-3
- [Icw] rated short-time withstand current: 50 A 131 °F (55 °C) for power circuit
- [Ie] rated operational current: 6 A at <= 440 V AC AC-3 12 A (at <131 °F (55 °C)) AC AC-1
- [Ith] conventional free air thermal current: 12 A (at 131 °F (55 °C)) for power circuit
- [Uc] control circuit voltage: 120 V AC 50/60 Hz
- [Ue] rated operational voltage: Power circuit 690 V AC 50/60 Hz
- [Ui] rated insulation voltage: 690 V IEC 60947 690 V VDE 0110 group C 690 V BS 5424 690 V UL 508 690 V CSA C22.2 No 14
- power pole contact composition: 2P
- product name: TeSys SK
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LC1SK0600G7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LC1SK0600G7
- Brand
- Schneider Electric
- Part Number
- LC1SK0600G7
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Standards
- EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
- product name
- TeSys SK
- Characteristic
- Value(s)
- Operating time
- 6...8 ms coil de-energisation and NO opening 7...14 ms coil energisation and NO closing
- Heat dissipation
- 1.4 W 50/60 Hz
- Mounting Support
- Rail
- Average impedance
- 4 mOhm - Ith 12 A 50 Hz
- Device short name
- LC1SK
- Tightening torque
- 7.08 lbf.in (0.8 N.m) connector pozidriv No 1
- Inrush power in VA
- 16 VA (at 68 °F (20 °C))
- Control circuit type
- AC 50/60 Hz
- Utilisation category
- AC-1 AC-3
- Contactor application
- Motor control Resistive load
- Mechanical durability
- 10 Mcycles
- Associated fuse rating
- 16 A gI at <= 440 V for power circuit conforming to IEC 60947
- Maximum operating rate
- 1200 cyc/h
- Product Certifications
- CB Scheme CE UKCA EAC cULus
- Connections - terminals
- Power circuit connector 1 0.0005â¦0.009 in² (0.35â¦6 mm²)flexible with cable end Power circuit connector 1 0.0008â¦0.009 in² (0.5â¦6 mm²)flexible without cable end Power circuit connector 1 0.002â¦0.009 in² (1.5â¦6 mm²)solid Power circuit connector 2 0.0005â¦0.002 in² (0.35â¦1.5 mm²)flexible with cable end Power circuit connector 2 0.0005â¦0.004 in² (0.35â¦2.5 mm²)flexible without cable end Power circuit connector 2 0.002â¦0.006 in² (1.5â¦4 mm²)solid
- Rated breaking capacity
- 52 A at <= 400 V for power circuit conforming to NF C 63-110 52 A at <= 400 V for power circuit conforming to IEC 60947
- Pole contact composition
- 2 NO
- Product or Component Type
- Mini contactor
- Irms rated making capacity
- 66 A at 690 V AC conforming to IEC 60947 66 A at 690 V AC conforming to NF C 63-110
- [Uc] control circuit voltage
- 120 V AC 50/60 Hz
- [Ui] rated insulation voltage
- 690 V IEC 60947 690 V VDE 0110 group C 690 V BS 5424 690 V UL 508 690 V CSA C22.2 No 14
- Control circuit voltage limits
- Operational: 0.85...1.1 Uc (at <122 °F (50 °C)) Drop-out: 0.2...0.75 Uc (at <122 °F (50 °C))
- [Ie] rated operational current
- 6 A at <= 440 V AC AC-3 12 A (at <131 °F (55 °C)) AC AC-1
- [Ue] rated operational voltage
- Power circuit 690 V AC 50/60 Hz
- power pole contact composition
- 2P
- Hold-in power consumption in VA
- 4.2 VA (at 68 °F (20 °C))
- [Icw] rated short-time withstand current
- 50 A 131 °F (55 °C) for power circuit
- [Ith] conventional free air thermal current
- 12 A (at 131 °F (55 °C)) for power circuit
Compatibility Information
Match LC1SK0600G7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1SK0600G7.
Maintenance Tips
Store LC1SK0600G7 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LC1SK0600G7 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LC1SK0600G7 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LC1SK0600G7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW