Schneider Electric LC1K16106K7
Product information
SKU: LC1K16106K7
Alternate: LC1K16106K7
Brand
Schneider Electric
Part No.
LC1K16106K7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LC1K16106K7
Product overview
The Schneider Electric LC1K16106K7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Auxiliary contact composition: 1 NO
- Auxiliary contacts type: type instantaneous 1 NO
- Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
- Characteristic: Value(s)
- Connections - terminals: Lugs-ring terminals (external diameter: 7 mm)
- Contactor application: Motor control
- Control circuit type: AC at 50/60 Hz
- Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
- Device application: Control
- Device short name: LC1K
- Heat dissipation: 1.3 W
- Hold-in power consumption in VA: 4.5 VA (at 20 °C)
- Inrush power in VA: 30 VA (at 20 °C)
- Insulation resistance: > 10 MOhm for signalling circuit
- Irms rated making capacity: 160 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- Maximum operating rate: 3600 cyc/h
- Minimum switching current: 5 mA for signalling circuit
- Minimum switching voltage: 17 V for signalling circuit
- Motor power kW: 4 kW at 220...230 V AC 50/60 Hz AC-3 7.5 kW at 380...415 V AC 50/60 Hz AC-3 5.5 kW at 440 V AC 50/60 Hz AC-3 4 kW at 690 V AC 50/60 Hz AC-3 4 kW at 220...230 V AC 50/60 Hz AC-3e 7.5 kW at 380...415 V AC 50/60 Hz AC-3e 5.5 kW at 440 V AC 50/60 Hz AC-3e 4 kW at 690 V AC 50/60 Hz AC-3e
- Mounting support: Plate Rail
- Non overlap distance: 0.5 mm
- Operating time: 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
- Overvoltage category: III
- Poles description: 3P
- Product or component type: Contactor
- Range: TeSys
- Rated breaking capacity: 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Signalling circuit frequency: <= 400 Hz
- Tightening torque: 0.8â¦1.3 N.m - on lugs-ring terminals Philips No 2 0.8â¦1.3 N.m - on lugs-ring terminals flat à 6 mm 0.8â¦1.3 N.m - on lugs-ring terminals pozidriv No 2
- Utilisation category: AC-3 AC-3e
- [Icw] rated short-time withstand current: 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
- [Ie] rated operational current: 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- [Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit
- [Uc] control circuit voltage: 100 V AC 50/60 Hz
- [Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz Signalling circuit: <= 690 V AC <= 400 Hz
- [Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14
- [Uimp] rated impulse withstand voltage: 8 kV
- power pole contact composition: 3 NO
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LC1K16106K7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LC1K16106K7
- Brand
- Schneider Electric
- Part Number
- LC1K16106K7
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Characteristic
- Value(s)
- Motor power kW
- 4 kW at 220...230 V AC 50/60 Hz AC-3 7.5 kW at 380...415 V AC 50/60 Hz AC-3 5.5 kW at 440 V AC 50/60 Hz AC-3 4 kW at 690 V AC 50/60 Hz AC-3 4 kW at 220...230 V AC 50/60 Hz AC-3e 7.5 kW at 380...415 V AC 50/60 Hz AC-3e 5.5 kW at 440 V AC 50/60 Hz AC-3e 4 kW at 690 V AC 50/60 Hz AC-3e
- Operating time
- 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
- Heat dissipation
- 1.3 W
- Mounting support
- Plate Rail
- Average impedance
- 3 mOhm - Ith 20 A 50 Hz for power circuit
- Device short name
- LC1K
- Poles description
- 3P
- Tightening torque
- 0.8â¦1.3 N.m - on lugs-ring terminals Philips No 2 0.8â¦1.3 N.m - on lugs-ring terminals flat à 6 mm 0.8â¦1.3 N.m - on lugs-ring terminals pozidriv No 2
- Device application
- Control
- Inrush power in VA
- 30 VA (at 20 °C)
- Control circuit type
- AC at 50/60 Hz
- Non overlap distance
- 0.5 mm
- Overvoltage category
- III
- Utilisation category
- AC-3 AC-3e
- Contactor application
- Motor control
- Insulation resistance
- > 10 MOhm for signalling circuit
- Associated fuse rating
- 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
- Maximum operating rate
- 3600 cyc/h
- Auxiliary contacts type
- type instantaneous 1 NO
- Connections - terminals
- Lugs-ring terminals (external diameter: 7 mm)
- Rated breaking capacity
- 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
- Safety reliability level
- B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Minimum switching current
- 5 mA for signalling circuit
- Minimum switching voltage
- 17 V for signalling circuit
- Product or component type
- Contactor
- Irms rated making capacity
- 160 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
- Signalling circuit frequency
- <= 400 Hz
- [Uc] control circuit voltage
- 100 V AC 50/60 Hz
- Auxiliary contact composition
- 1 NO
- [Ui] rated insulation voltage
- Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14
- Control circuit voltage limits
- Operational: 0.8...1.15 Uc (at <50 °C) Drop-out: >= 0.20 Uc (at <50 °C)
- [Ie] rated operational current
- 16 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 16 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- [Ue] rated operational voltage
- Power circuit: <= 690 V AC <= 400 Hz Signalling circuit: <= 690 V AC <= 400 Hz
- power pole contact composition
- 3 NO
- Hold-in power consumption in VA
- 4.5 VA (at 20 °C)
- [Uimp] rated impulse withstand voltage
- 8 kV
- [Icw] rated short-time withstand current
- 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
- [Ith] conventional free air thermal current
- 20 A (at 60 °C) for power circuit 10 A (at 50 °C) for signalling circuit
Compatibility Information
Match LC1K16106K7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1K16106K7.
Maintenance Tips
Store LC1K16106K7 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LC1K16106K7 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LC1K16106K7 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LC1K16106K7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.