+86 13348028050
LC1K1210L7 Schneider Electric LC1K1210L7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1K1210L7

Product information

SKU: LC1K1210L7

Alternate: LC1K1210L7

Brand
Schneider Electric
Part No.
LC1K1210L7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1K1210L7 Product overview The Schneider Electric LC1K1210L7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 - Auxiliary contact composition: 1 NO - Auxiliary contacts type: Instantaneous 1 NO - Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit - Characteristic: Value(s) - Connections - terminals: screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end - Contactor application: Motor control Resistive load - Control circuit type: AC 50/60 Hz - Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: >= 0.20 Uc (at <122 °F (50 °C)) - Device Application: Control - Device short name: LC1K - Heat dissipation: 1.3 W - Hold-in power consumption in VA: 4.5 VA (at 68 °F (20 °C)) - Inrush power in VA: 30 VA (at 68 °F (20 °C)) - Insulation resistance: > 10 MOhm for signalling circuit - Irms rated making capacity: 144 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h - Minimum switching current: 5 mA for signalling circuit - Minimum switching voltage: 17 V for signalling circuit - Motor power kW: 3 kW 220...230 V AC 50/60 Hz AC-3 5.5 kW 380...415 V AC 50/60 Hz AC-3 5.5 kW 440 V AC 50/60 Hz AC-3 4 kW 690 V AC 50/60 Hz AC-3 3 kW 220...230 V AC 50/60 Hz AC-3e 5.5 kW 380...415 V AC 50/60 Hz AC-3e 5.5 kW 440 V AC 50/60 Hz AC-3e 4 kW 690 V AC 50/60 Hz AC-3e 3 kW 220...230 V AC 50/60 Hz AC-4 5.5 kW 380...415 V AC 50/60 Hz AC-4 5.5 kW 440 V AC 50/60 Hz AC-4 4 kW 690 V AC 50/60 Hz AC-4 - Mounting Support: Plate Rail - Overvoltage category: III - Poles description: 3P - Product or Component Type: Contactor - Range: TeSys - Rated breaking capacity: 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 - Signalling circuit frequency: <= 400 Hz - Tightening torque: 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 - Utilisation category: AC-3 AC-3e AC-1 AC-4 - [Icw] rated short-time withstand current: 115 A 122 °F (50 °C) - 1 s for power circuit 105 A 122 °F (50 °C) - 5 s for power circuit 100 A 122 °F (50 °C) - 10 s for power circuit 75 A 122 °F (50 °C) - 30 s for power circuit 55 A 122 °F (50 °C) - 1 min for power circuit 50 A 122 °F (50 °C) - 3 min for power circuit 25 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit - [Ie] rated operational current: 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit - [Uc] control circuit voltage: 200...208 V AC 50/60 Hz - [Ue] rated operational voltage: Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz - [Ui] rated insulation voltage: Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14 - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1K1210L7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1K1210L7
Brand
Schneider Electric
Part Number
LC1K1210L7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Characteristic
Value(s)
Motor power kW
3 kW 220...230 V AC 50/60 Hz AC-3 5.5 kW 380...415 V AC 50/60 Hz AC-3 5.5 kW 440 V AC 50/60 Hz AC-3 4 kW 690 V AC 50/60 Hz AC-3 3 kW 220...230 V AC 50/60 Hz AC-3e 5.5 kW 380...415 V AC 50/60 Hz AC-3e 5.5 kW 440 V AC 50/60 Hz AC-3e 4 kW 690 V AC 50/60 Hz AC-3e 3 kW 220...230 V AC 50/60 Hz AC-4 5.5 kW 380...415 V AC 50/60 Hz AC-4 5.5 kW 440 V AC 50/60 Hz AC-4 4 kW 690 V AC 50/60 Hz AC-4
Heat dissipation
1.3 W
Mounting Support
Plate Rail
Average impedance
3 mOhm - Ith 20 A 50 Hz for power circuit
Device short name
LC1K
Poles description
3P
Tightening torque
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
Device Application
Control
Inrush power in VA
30 VA (at 68 °F (20 °C))
Control circuit type
AC 50/60 Hz
Overvoltage category
III
Utilisation category
AC-3 AC-3e AC-1 AC-4
Contactor application
Motor control Resistive load
Insulation resistance
> 10 MOhm for signalling circuit
Associated fuse rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660
Maximum operating rate
3600 cyc/h
Auxiliary contacts type
Instantaneous 1 NO
Connections - terminals
screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Rated breaking capacity
110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Product or Component Type
Contactor
Irms rated making capacity
144 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947
Signalling circuit frequency
<= 400 Hz
[Uc] control circuit voltage
200...208 V AC 50/60 Hz
Auxiliary contact composition
1 NO
[Ui] rated insulation voltage
Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-4-1 Signalling circuit 690 V IEC 60947-5-1 Signalling circuit 600 V UL 508 Power circuit 600 V CSA C22.2 No 14 Signalling circuit 600 V CSA C22.2 No 14
Control circuit voltage limits
Operational: 0.8...1.15 Uc (at <122 °F (50 °C)) Drop-out: >= 0.20 Uc (at <122 °F (50 °C))
[Ie] rated operational current
12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC <= 400 Hz Signalling circuit <= 690 V AC <= 400 Hz
power pole contact composition
3 NO
Hold-in power consumption in VA
4.5 VA (at 68 °F (20 °C))
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
115 A 122 °F (50 °C) - 1 s for power circuit 105 A 122 °F (50 °C) - 5 s for power circuit 100 A 122 °F (50 °C) - 10 s for power circuit 75 A 122 °F (50 °C) - 30 s for power circuit 55 A 122 °F (50 °C) - 1 min for power circuit 50 A 122 °F (50 °C) - 3 min for power circuit 25 A 122 °F (50 °C) - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current
20 A (at 140 °F (60 °C)) for power circuit 10 A (at 122 °F (50 °C)) for signalling circuit

Compatibility Information

Match LC1K1210L7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1K1210L7.

Maintenance Tips

Store LC1K1210L7 dry and dust-free in its packaging until installation.

Frequently Asked Questions