Product Description

Schneider Electric LC1F800 Product overview The Schneider Electric LC1F800 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 1000 A gG at <= 440 V 800 A aM at <= 440 V - Average impedance: 0.12 mOhm - Ith 1000 A 50 Hz - Characteristic: Value(s) - Compatibility code: LC1F - Connections - terminals: Power circuit bar 2 60 x 5 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - Contactor application: Motor control Resistive load - Control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.3...0.5 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil - Device short name: LC1F - Heat dissipation: 25 W 2.2…5.5 W - Hold-in power consumption in VA: 12 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 12 VA (at 68 °F (20 °C))with LX4 coil 7…10 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 4.0…5.5 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil - Inrush power in VA: 1700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 1900 VA (at 68 °F (20 °C))with LX4 coil 460…730 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 500…680 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil - Irms rated making capacity: 8000 A AC conforming to IEC 60947-4-1 - Maximum operating rate: 600 cyc/h 131 °F (55 °C) - Mechanical durability: 5 Mcycles - Motor power kW: 450 kW at 1000 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4) 450 kW at 380...400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 220...240 V AC 50/60 Hz (AC-3) - Mounting Support: Plate - Operating time: 60...80 ms closing with LX1/LX9 coil 160...180 ms opening with LX1/LX9 coil 60...80 ms closing with LX4 coil 40...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 120 W AC-1 77 W AC-3 - Product Certifications: CB CSA LROS (Lloyds register of shipping) ABS CCC UL UKCA - Product or Component Type: Contactor - Range: TeSys - Rated breaking capacity: 6400 A conforming to IEC 60947-4-1 - Standards: IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1 - Tightening torque: Power circuit 513.3 lbf.in (58 N.m) Control circuit 10.6 lbf.in (1.2 N.m) - Utilisation category: AC-3 AC-1 AC-4 - [Icw] rated short-time withstand current: 2600 A 104 °F (40 °C) - 3 min 5500 A 104 °F (40 °C) - 10 s 4600 A 104 °F (40 °C) - 30 s 3600 A 104 °F (40 °C) - 1 min 1700 A 104 °F (40 °C) - 10 min - [Ie] rated operational current: 1000 A 104 °F (40 °C)) <= 440 V AC AC-1 800 A 131 °F (55 °C)) <= 440 V AC AC-3 - [Ith] conventional free air thermal current: 1000 A (at 104 °F (40 °C)) - [Uc] control circuit voltage: 110...400 V AC 40...400 Hz with LX1/LX9 coil 110...400 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil - [Ue] rated operational voltage: <= 1000 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V IEC 60947-4-1 1500 V VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO - product name: TeSys F Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F800 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F800
Brand
Schneider Electric
Part Number
LC1F800
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Standards
IEC 60947-1 JIS C8201-4-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1
product name
TeSys F
Characteristic
Value(s)
Motor power kW
450 kW at 1000 V AC 50/60 Hz (AC-3) 450 kW at 500 V AC 50/60 Hz (AC-3) 475 kW at 660...690 V AC 50/60 Hz (AC-3) 110 kW at 400 V AC 50/60 Hz (AC-4) 450 kW at 380...400 V AC 50/60 Hz (AC-3) 450 kW at 415 V AC 50/60 Hz (AC-3) 450 kW at 440 V AC 50/60 Hz (AC-3) 250 kW at 220...240 V AC 50/60 Hz (AC-3)
Operating time
60...80 ms closing with LX1/LX9 coil 160...180 ms opening with LX1/LX9 coil 60...80 ms closing with LX4 coil 40...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil
Heat dissipation
25 W 2.2…5.5 W
Mounting Support
Plate
Average impedance
0.12 mOhm - Ith 1000 A 50 Hz
Device short name
LC1F
Poles description
3P
Tightening torque
Power circuit 513.3 lbf.in (58 N.m) Control circuit 10.6 lbf.in (1.2 N.m)
Compatibility code
LC1F
Inrush power in VA
1700 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 1900 VA (at 68 °F (20 °C))with LX4 coil 460…730 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 500…680 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil
Overvoltage category
III
Utilisation category
AC-3 AC-1 AC-4
Contactor application
Motor control Resistive load
Mechanical durability
5 Mcycles
Associated fuse rating
1000 A gG at <= 440 V 800 A aM at <= 440 V
Maximum operating rate
600 cyc/h 131 °F (55 °C)
Product Certifications
CB CSA LROS (Lloyds register of shipping) ABS CCC UL UKCA
Connections - terminals
Power circuit bar 2 60 x 5 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)
Rated breaking capacity
6400 A conforming to IEC 60947-4-1
Product or Component Type
Contactor
Irms rated making capacity
8000 A AC conforming to IEC 60947-4-1
Power dissipation per pole
120 W AC-1 77 W AC-3
[Uc] control circuit voltage
110...400 V AC 40...400 Hz with LX1/LX9 coil 110...400 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX1/LX9 coil Drop-out: 0.3...0.5 Uc AC 40...400 Hz with LX1/LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.3...0.5 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil
[Ie] rated operational current
1000 A 104 °F (40 °C)) <= 440 V AC AC-1 800 A 131 °F (55 °C)) <= 440 V AC AC-3
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
power pole contact composition
3 NO
Hold-in power consumption in VA
12 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX1/LX9 coil 12 VA (at 68 °F (20 °C))with LX4 coil 7…10 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 4.0…5.5 VA cos phi 0.5 (at 68 °F (20 °C))with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
2600 A 104 °F (40 °C) - 3 min 5500 A 104 °F (40 °C) - 10 s 4600 A 104 °F (40 °C) - 30 s 3600 A 104 °F (40 °C) - 1 min 1700 A 104 °F (40 °C) - 10 min
[Ith] conventional free air thermal current
1000 A (at 104 °F (40 °C))

Compatibility Information

Match LC1F800 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F800.

Maintenance Tips

Store LC1F800 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options