+86 13348028050
LC1F500R7 Schneider Electric LC1F500R7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1F500R7

Product information

SKU: LC1F500R7

Alternate: LC1F500R7

Brand
Schneider Electric
Part No.
LC1F500R7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1F500R7 Product overview The Schneider Electric LC1F500R7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 500 A aM at <= 440 V 800 A gG at <= 440 V - Average impedance: 0.18 mOhm - Ith 700 A 50 Hz - Characteristic: Value(s) - Compatibility code: LC1F - Connections - terminals: Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 40 x 5 mm Power circuit lugs-ring terminals 2 0.4 in² (240 mm²) Power circuit bolted connection - Contactor application: Resistive load Motor control - Control circuit type: AC 40...400 Hz - Control circuit voltage limits: Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C)) - Device short name: LC1F - Heat dissipation: 18 W - Hold-in power consumption in VA: 18 VA, 40...400 Hz 0.9 68 °F (20 °C)) - Inrush power in VA: 1100 VA, 40...400 Hz 0.9 68 °F (20 °C)) - Maximum operating rate: 2400 cyc/h 131 °F (55 °C) - Mechanical durability: 10 Mcycles - Motor power kW: 250 kW at 380...400 V AC 50/60 Hz (AC-3) 280 kW at 415 V AC 50/60 Hz (AC-3) 295 kW at 440 V AC 50/60 Hz (AC-3) 355 kW at 500 V AC 50/60 Hz (AC-3) 335 kW at 660...690 V AC 50/60 Hz (AC-3) 335 kW at 1000 V AC 50/60 Hz (AC-3) 147 kW at 220...230 V AC 50/60 Hz (AC-3) 80 kW at 400 V AC 50/60 Hz (AC-4) - Mounting Support: Plate - Operating time: 40...65 ms closing 100...170 ms opening - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 88 W AC-1 45 W AC-3 - Product Certifications: LROS (Lloyds register of shipping) DNV CB ABS CCC UL BV RMRoS RINA UKCA - Product or Component Type: Contactor - Range: TeSys - Range of Product: TeSys F - Rated breaking capacity: 4000 A conforming to IEC 60947-4-1 - Standards: JIS C8201-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1 - Tightening torque: Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m) - Utilisation category: AC-4 AC-1 AC-3 - [Icw] rated short-time withstand current: 4200 A 104 °F (40 °C) - 10 s 3200 A 104 °F (40 °C) - 30 s 2400 A 104 °F (40 °C) - 1 min 1500 A 104 °F (40 °C) - 3 min 1200 A 104 °F (40 °C) - 10 min - [Ie] rated operational current: 700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 - [Ith] conventional free air thermal current: 700 A (at 104 °F (40 °C)) - [Uc] control circuit voltage: 440 V AC 40...400 Hz - [Ue] rated operational voltage: <= 1000 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V IEC 60947-4-1 1500 V VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F500R7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F500R7
Brand
Schneider Electric
Part Number
LC1F500R7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
JIS C8201-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1
Characteristic
Value(s)
Motor power kW
250 kW at 380...400 V AC 50/60 Hz (AC-3) 280 kW at 415 V AC 50/60 Hz (AC-3) 295 kW at 440 V AC 50/60 Hz (AC-3) 355 kW at 500 V AC 50/60 Hz (AC-3) 335 kW at 660...690 V AC 50/60 Hz (AC-3) 335 kW at 1000 V AC 50/60 Hz (AC-3) 147 kW at 220...230 V AC 50/60 Hz (AC-3) 80 kW at 400 V AC 50/60 Hz (AC-4)
Operating time
40...65 ms closing 100...170 ms opening
Heat dissipation
18 W
Mounting Support
Plate
Range of Product
TeSys F
Average impedance
0.18 mOhm - Ith 700 A 50 Hz
Device short name
LC1F
Poles description
3P
Tightening torque
Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)
Compatibility code
LC1F
Inrush power in VA
1100 VA, 40...400 Hz 0.9 68 °F (20 °C))
Control circuit type
AC 40...400 Hz
Overvoltage category
III
Utilisation category
AC-4 AC-1 AC-3
Contactor application
Resistive load Motor control
Mechanical durability
10 Mcycles
Associated fuse rating
500 A aM at <= 440 V 800 A gG at <= 440 V
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Product Certifications
LROS (Lloyds register of shipping) DNV CB ABS CCC UL BV RMRoS RINA UKCA
Connections - terminals
Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end Power circuit bar 2 40 x 5 mm Power circuit lugs-ring terminals 2 0.4 in² (240 mm²) Power circuit bolted connection
Rated breaking capacity
4000 A conforming to IEC 60947-4-1
Product or Component Type
Contactor
Power dissipation per pole
88 W AC-1 45 W AC-3
[Uc] control circuit voltage
440 V AC 40...400 Hz
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limits
Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 40...400 Hz 131 °F (55 °C))
[Ie] rated operational current
700 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 500 A (at <131 °F (55 °C)) at <= 440 V AC AC-3
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz <= 460 V DC
power pole contact composition
3 NO
Hold-in power consumption in VA
18 VA, 40...400 Hz 0.9 68 °F (20 °C))
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
4200 A 104 °F (40 °C) - 10 s 3200 A 104 °F (40 °C) - 30 s 2400 A 104 °F (40 °C) - 1 min 1500 A 104 °F (40 °C) - 3 min 1200 A 104 °F (40 °C) - 10 min
[Ith] conventional free air thermal current
700 A (at 104 °F (40 °C))

Compatibility Information

Match LC1F500R7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F500R7.

Maintenance Tips

Store LC1F500R7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options