+86 13348028050
LC1F225V7 Schneider Electric LC1F225V7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1F225V7

Product information

SKU: LC1F225V7

Alternate: LC1F225V7

Brand
Schneider Electric
Part No.
LC1F225V7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1F225V7 Product overview The Schneider Electric LC1F225V7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 315 A gG at <= 440 V 250 A aM at <= 440 V - Average impedance: 0.32 mOhm - Ith 315 A 50 Hz - Characteristic: Value(s) - Compatibility code: LC1F - Connections - terminals: Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection - Contactor application: Resistive load Motor control - Contactor coil voltage: 400 V AC standard - Control circuit type: AC at 40...400 Hz - Control circuit voltage limits: Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C) - Device short name: LC1F - Heat dissipation: 8…9.8 W - Hold-in power consumption in VA: 9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C) - Inrush power in VA: 1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C) - Maximum operating rate: 2400 cyc/h 55 °C - Mechanical durability: 10 Mcycles - Motor power kW: 110 kW at 380...400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660...690 V AC 50/60 Hz (AC-3) 63 kW at 220...230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4) - Motor starter type: Direct on-line contactor - Mounting support: Plate - Operating time: 35 ms closing (at Uc) 130 ms opening (at Uc) - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 32 W AC-1 16 W AC-3 - Product certifications: ABS LROS (Lloyds register of shipping) RINA DNV BV CSA UL RMRoS CB UKCA - Product or component type: Contactor - Range: TeSys - Range of product: TeSys F - Rated breaking capacity: 1800 A conforming to IEC 60947-4-1 - Standards: IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 - Tightening torque: Control circuit: 1.2 N.m Power circuit: 35 N.m - Utilisation category: AC-3 AC-4 AC-1 - [Icw] rated short-time withstand current: 1800 A 40 °C - 10 s 1000 A 40 °C - 30 s 850 A 40 °C - 1 min 560 A 40 °C - 3 min 440 A 40 °C - 10 min - [Ie] rated operational current: 315 A (at <40 °C) at <= 440 V AC-1 225 A (at <55 °C) at <= 440 V AC-3 - [Ith] conventional free air thermal current: 315 A (at 40 °C) - [Uc] control circuit voltage: 400 V AC 40...400 Hz - [Ue] rated operational voltage: <= 460 V DC <= 690 V AC 50/60 Hz - [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - motor power range: 55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases - power pole contact composition: 3 NO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F225V7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F225V7
Brand
Schneider Electric
Part Number
LC1F225V7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1
Characteristic
Value(s)
Motor power kW
110 kW at 380...400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660...690 V AC 50/60 Hz (AC-3) 63 kW at 220...230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4)
Operating time
35 ms closing (at Uc) 130 ms opening (at Uc)
Heat dissipation
8…9.8 W
Mounting support
Plate
Range of product
TeSys F
Average impedance
0.32 mOhm - Ith 315 A 50 Hz
Device short name
LC1F
Poles description
3P
Tightening torque
Control circuit: 1.2 N.m Power circuit: 35 N.m
motor power range
55…100 kW at 200…240 V 3 phases 110…220 kW at 480…500 V 3 phases 110…220 kW at 380…440 V 3 phases
Compatibility code
LC1F
Inrush power in VA
1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Motor starter type
Direct on-line contactor
Control circuit type
AC at 40...400 Hz
Overvoltage category
III
Utilisation category
AC-3 AC-4 AC-1
Contactor application
Resistive load Motor control
Mechanical durability
10 Mcycles
Associated fuse rating
315 A gG at <= 440 V 250 A aM at <= 440 V
Contactor coil voltage
400 V AC standard
Maximum operating rate
2400 cyc/h 55 °C
Product certifications
ABS LROS (Lloyds register of shipping) RINA DNV BV CSA UL RMRoS CB UKCA
Connections - terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection
Rated breaking capacity
1800 A conforming to IEC 60947-4-1
Product or component type
Contactor
Power dissipation per pole
32 W AC-1 16 W AC-3
[Uc] control circuit voltage
400 V AC 40...400 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Control circuit voltage limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
[Ie] rated operational current
315 A (at <40 °C) at <= 440 V AC-1 225 A (at <55 °C) at <= 440 V AC-3
[Ue] rated operational voltage
<= 460 V DC <= 690 V AC 50/60 Hz
power pole contact composition
3 NO
Hold-in power consumption in VA
9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
1800 A 40 °C - 10 s 1000 A 40 °C - 30 s 850 A 40 °C - 1 min 560 A 40 °C - 3 min 440 A 40 °C - 10 min
[Ith] conventional free air thermal current
315 A (at 40 °C)

Compatibility Information

Match LC1F225V7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F225V7.

Maintenance Tips

Store LC1F225V7 dry and dust-free in its packaging until installation.