+86 13348028050
LC1F1854 Schneider Electric LC1F1854 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1F1854

Product information

SKU: LC1F1854

Alternate: LC1F1854

Brand
Schneider Electric
Part No.
LC1F1854
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1F1854 Product overview The Schneider Electric LC1F1854 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 315 A gG at <= 440 V - Average impedance: 0.33 mOhm - Ith 275 A 50 Hz - Characteristic: Value(s) - Compatibility code: LC1F - Connections - terminals: Power circuit bar 2 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (150 mm²) Power circuit connector 1 0.2 in² (150 mm²) Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end - Contactor application: Resistive load - Control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil - Device short name: LC1F - Heat dissipation: 8…9.8 W 2.2…2.5 W - Hold-in power consumption in VA: 8.9…10.9 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 4.13…5.07 VA (at 68 °F (20 °C))with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 2.5…4.0 VA (at 68 °F (20 °C))with LXE coil - Inrush power in VA: 950…1180 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 737…902 VA (at 68 °F (20 °C))with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270…320 VA (at 68 °F (20 °C))with LXE coil - Irms rated making capacity: 1850 A conforming to IEC 60947-4-1 - Maximum operating rate: 2400 cyc/h 131 °F (55 °C) - Mechanical durability: 10 Mcycles - Mounting Support: Plate - Operating time: 35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil - Overvoltage category: III - Poles description: 4P - Power dissipation per pole: 25 W AC-1 - Product Certifications: ABS CSA DNV BV UL CB RMRoS LROS (Lloyds register of shipping) RINA UKCA - Product or Component Type: Contactor - Range: TeSys - Rated breaking capacity: 1480 A conforming to IEC 60947-4-1 - Standards: EN 60947-4-1 IEC 60947-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 - Tightening torque: Power circuit 159.3 lbf.in (18 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m) - Utilisation category: AC-1 - [Icw] rated short-time withstand current: 1500 A 104 °F (40 °C) - 10 s 920 A 104 °F (40 °C) - 30 s 740 A 104 °F (40 °C) - 1 min 500 A 104 °F (40 °C) - 3 min 400 A 104 °F (40 °C) - 10 min - [Ie] rated operational current: 275 A 104 °F (40 °C)) <= 440 V AC-1 - [Ith] conventional free air thermal current: 275 A (at 104 °F (40 °C)) - [Uc] control circuit voltage: 24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil - [Ue] rated operational voltage: <= 690 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V IEC 60947-4-1 1500 V VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 4 NO - product name: TeSys F Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F1854 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F1854
Brand
Schneider Electric
Part Number
LC1F1854
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
EN 60947-4-1 IEC 60947-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1
product name
TeSys F
Characteristic
Value(s)
Operating time
35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil
Heat dissipation
8…9.8 W 2.2…2.5 W
Mounting Support
Plate
Average impedance
0.33 mOhm - Ith 275 A 50 Hz
Device short name
LC1F
Poles description
4P
Tightening torque
Power circuit 159.3 lbf.in (18 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m)
Compatibility code
LC1F
Inrush power in VA
950…1180 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 737…902 VA (at 68 °F (20 °C))with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270…320 VA (at 68 °F (20 °C))with LXE coil
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Mechanical durability
10 Mcycles
Associated fuse rating
315 A gG at <= 440 V
Maximum operating rate
2400 cyc/h 131 °F (55 °C)
Product Certifications
ABS CSA DNV BV UL CB RMRoS LROS (Lloyds register of shipping) RINA UKCA
Connections - terminals
Power circuit bar 2 25 x 3 mm Power circuit lugs-ring terminals 1 0.2 in² (150 mm²) Power circuit connector 1 0.2 in² (150 mm²) Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end
Rated breaking capacity
1480 A conforming to IEC 60947-4-1
Product or Component Type
Contactor
Irms rated making capacity
1850 A conforming to IEC 60947-4-1
Power dissipation per pole
25 W AC-1
[Uc] control circuit voltage
24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil
[Ie] rated operational current
275 A 104 °F (40 °C)) <= 440 V AC-1
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz <= 460 V DC
power pole contact composition
4 NO
Hold-in power consumption in VA
8.9…10.9 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 4.13…5.07 VA (at 68 °F (20 °C))with LX4 coil 4.5…7.0 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 2.5…4.0 VA (at 68 °F (20 °C))with LXE coil
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
1500 A 104 °F (40 °C) - 10 s 920 A 104 °F (40 °C) - 30 s 740 A 104 °F (40 °C) - 1 min 500 A 104 °F (40 °C) - 3 min 400 A 104 °F (40 °C) - 10 min
[Ith] conventional free air thermal current
275 A (at 104 °F (40 °C))

Compatibility Information

Match LC1F1854 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F1854.

Maintenance Tips

Store LC1F1854 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.