+86 13348028050
LC1F1154P7 Schneider Electric LC1F1154P7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1F1154P7

Product information

SKU: LC1F1154P7

Alternate: LC1F1154P7

Brand
Schneider Electric
Part No.
LC1F1154P7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1F1154P7 Product overview The Schneider Electric LC1F1154P7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A aM at <= 440 V 200 A gG at <= 440 V - Average impedance: 0.37 mOhm - Ith 200 A 50 Hz - Characteristic: Value(s) - Compatibility code: LC1F - Connections - terminals: Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bolted connection - Contactor application: Resistive load - Control circuit type: AC at 40...400 Hz - Control circuit voltage limits: Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C) - Device short name: LC1F - Heat dissipation: 5.9…7.2 W - Hold-in power consumption in VA: 8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C) - Inrush power in VA: 770 VA, 40...400 Hz cos phi 0.9 (at 20 °C) - Maximum operating rate: 2400 cyc/h 55 °C - Mechanical durability: 10 Mcycles - Mounting support: Plate - Operating time: 35 ms closing (at Uc) 130 ms opening (at Uc) - Overvoltage category: III - Poles description: 4P - Power dissipation per pole: 15 W AC-1 - Product certifications: CCC LROS (Lloyds register of shipping) DNV RMRoS ABS RINA BV UL CB UKCA - Product or component type: Contactor - Range: TeSys - Range of product: TeSys F - Rated breaking capacity: 920 A conforming to IEC 60947-4-1 - Standards: IEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1 - Tightening torque: Power circuit: 10 N.m Control circuit: 1.2 N.m - Utilisation category: AC-1 - [Icw] rated short-time withstand current: 1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min - [Ie] rated operational current: 200 A (at <40 °C) at <= 440 V AC-1 - [Ith] conventional free air thermal current: 200 A (at 40 °C) - [Uc] control circuit voltage: 230 V AC 40...400 Hz - [Ue] rated operational voltage: <= 690 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 4 NO Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F1154P7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F1154P7
Brand
Schneider Electric
Part Number
LC1F1154P7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Standards
IEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1
Characteristic
Value(s)
Operating time
35 ms closing (at Uc) 130 ms opening (at Uc)
Heat dissipation
5.9…7.2 W
Mounting support
Plate
Range of product
TeSys F
Average impedance
0.37 mOhm - Ith 200 A 50 Hz
Device short name
LC1F
Poles description
4P
Tightening torque
Power circuit: 10 N.m Control circuit: 1.2 N.m
Compatibility code
LC1F
Inrush power in VA
770 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Control circuit type
AC at 40...400 Hz
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Mechanical durability
10 Mcycles
Associated fuse rating
125 A aM at <= 440 V 200 A gG at <= 440 V
Maximum operating rate
2400 cyc/h 55 °C
Product certifications
CCC LROS (Lloyds register of shipping) DNV RMRoS ABS RINA BV UL CB UKCA
Connections - terminals
Power circuit: bar 2 cable(s) - busbar cross section: 20 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 95 mm² Power circuit: connector 1 cable(s) 95 mm² Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bolted connection
Rated breaking capacity
920 A conforming to IEC 60947-4-1
Product or component type
Contactor
Power dissipation per pole
15 W AC-1
[Uc] control circuit voltage
230 V AC 40...400 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Control circuit voltage limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
[Ie] rated operational current
200 A (at <40 °C) at <= 440 V AC-1
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz <= 460 V DC
power pole contact composition
4 NO
Hold-in power consumption in VA
8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
1100 A 40 °C - 10 s 640 A 40 °C - 30 s 520 A 40 °C - 1 min 400 A 40 °C - 3 min 320 A 40 °C - 10 min
[Ith] conventional free air thermal current
200 A (at 40 °C)

Compatibility Information

Match LC1F1154P7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F1154P7.

Maintenance Tips

Store LC1F1154P7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options