+86 13348028050
LC1F115 Schneider Electric LC1F115 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1F115

Product information

$348.25 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LC1F115

Alternate: LC1F115

Brand
Schneider Electric
Part No.
LC1F115
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1F115 Product overview The Schneider Electric LC1F115 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A aM at <= 440 V 200 A gG at <= 440 V - Average impedance: 0.37 mOhm - Ith 200 A 50 Hz - Characteristic: Value(s) - Connections - terminals: Power circuit lugs-ring terminals 1 0.1 in² (95 mm²) Power circuit connector 1 0.1 in² (95 mm²) Power circuit bar 2 20 x 3 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end - Contactor application: Resistive load Motor control - Control circuit voltage limits: Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil - Device short name: LC1F - Heat dissipation: 5.9…7.2 W 2.2…5.5 W - Hold-in power consumption in VA: 6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil - Inrush power in VA: 590…855 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 543…665 VA (at 68 °F (20 °C))with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270…320 VA (at 68 °F (20 °C))with LXE coil - Irms rated making capacity: 1150 A conforming to IEC 60947-4-1 - Mechanical durability: 10 Mcycles - Motor power kW: 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 220...240 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) - Mounting Support: Plate - Operating time: 35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil - Overvoltage category: III - Poles description: 3P - Power dissipation per pole: 15 W AC-1 5 W AC-3 - Product Certifications: RINA ABS CSA DNV RMRoS BV LROS (Lloyds register of shipping) UL CB UKCA - Product or Component Type: Contactor - Range: TeSys - Rated breaking capacity: 920 A conforming to IEC 60947-4-1 - Standards: EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1 - Tightening torque: Power circuit 88.5 lbf.in (10 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m) - Utilisation category: AC-1 AC-4 AC-3 - [Icw] rated short-time withstand current: 1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min - [Ie] rated operational current: 200 A 104 °F (40 °C)) <= 440 V AC-1 115 A 131 °F (55 °C)) <= 440 V AC-3 - [Ith] conventional free air thermal current: 200 A (at 104 °F (40 °C)) - [Uc] control circuit voltage: 24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil - [Ue] rated operational voltage: <= 690 V AC 50/60 Hz <= 460 V DC - [Ui] rated insulation voltage: 1000 V IEC 60947-4-1 1500 V VDE 0110 group C - [Uimp] rated impulse withstand voltage: 8 kV - power pole contact composition: 3 NO - product name: TeSys F Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1F115 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1F115
Brand
Schneider Electric
Part Number
LC1F115
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Standards
EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1
product name
TeSys F
Characteristic
Value(s)
Motor power kW
55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415 V AC 50/60 Hz (AC-3) 59 kW at 440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 220...240 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)
Operating time
35 ms closing with LX9 coil 130 ms opening with LX9 coil 30...40 ms closing with LX4 coil 30...50 ms opening with LX4 coil 40...80 ms closing with LXE coil 6...54 ms opening with LXE coil
Heat dissipation
5.9…7.2 W 2.2…5.5 W
Mounting Support
Plate
Average impedance
0.37 mOhm - Ith 200 A 50 Hz
Device short name
LC1F
Poles description
3P
Tightening torque
Power circuit 88.5 lbf.in (10 N.m) Control circuit 10.6 lbf.in (1.2 N.m) Control circuit 5.3 lbf.in (0.6 N.m)
Inrush power in VA
590…855 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil 543…665 VA (at 68 °F (20 °C))with LX4 coil 280…310 VA, 50/60 Hz cos phi 0.5 (at 68 °F (20 °C))with LXE coil 270…320 VA (at 68 °F (20 °C))with LXE coil
Overvoltage category
III
Utilisation category
AC-1 AC-4 AC-3
Contactor application
Resistive load Motor control
Mechanical durability
10 Mcycles
Associated fuse rating
125 A aM at <= 440 V 200 A gG at <= 440 V
Product Certifications
RINA ABS CSA DNV RMRoS BV LROS (Lloyds register of shipping) UL CB UKCA
Connections - terminals
Power circuit lugs-ring terminals 1 0.1 in² (95 mm²) Power circuit connector 1 0.1 in² (95 mm²) Power circuit bar 2 20 x 3 mm Power circuit bolted connection Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid without cable end Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)flexible without cable end Control circuit screw clamp terminals 1.0 0.0004…0.004 in² (0.25…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1.0 0.0003…0.004 in² (0.2…2.5 mm²)solid without cable end
Rated breaking capacity
920 A conforming to IEC 60947-4-1
Product or Component Type
Contactor
Irms rated making capacity
1150 A conforming to IEC 60947-4-1
Power dissipation per pole
15 W AC-1 5 W AC-3
[Uc] control circuit voltage
24...575 V AC 40...400 Hz with LX9 coil 24...460 V DC with LX4 coil 100...250 V AC 50/60 Hz with LXE coil 100...380 V DC with LXE coil
[Ui] rated insulation voltage
1000 V IEC 60947-4-1 1500 V VDE 0110 group C
Control circuit voltage limits
Operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil Drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil Operational: 0.85...1.1 Uc DC with LX4 coil Drop-out: 0.15...0.2 Uc DC with LX4 coil Operational: 85...275 V AC 50/60 Hz with LXE coil Drop-out: 0...60 V AC 50/60 Hz with LXE coil Operational: 85...418 V DC with LXE coil Drop-out: 0...45 V DC with LXE coil
[Ie] rated operational current
200 A 104 °F (40 °C)) <= 440 V AC-1 115 A 131 °F (55 °C)) <= 440 V AC-3
[Ue] rated operational voltage
<= 690 V AC 50/60 Hz <= 460 V DC
power pole contact composition
3 NO
Hold-in power consumption in VA
6.6…8.1 VA, 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))with LX9 coil
[Uimp] rated impulse withstand voltage
8 kV
[Icw] rated short-time withstand current
1100 A 104 °F (40 °C) - 10 s 640 A 104 °F (40 °C) - 30 s 520 A 104 °F (40 °C) - 1 min 400 A 104 °F (40 °C) - 3 min 320 A 104 °F (40 °C) - 10 min
[Ith] conventional free air thermal current
200 A (at 104 °F (40 °C))

Compatibility Information

Match LC1F115 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1F115.

Maintenance Tips

Store LC1F115 dry and dust-free in its packaging until installation.