+86 13348028050
LC1D806BW Schneider Electric LC1D806BW - Front View | Vcocnc FANUC Parts

Schneider Electric LC1D806BW

Product information

SKU: LC1D806BW

Alternate: LC1D806BW

Brand
Schneider Electric
Part No.
LC1D806BW
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1D806BW Product overview The Schneider Electric LC1D806BW is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit - Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Without built-in suppressor module - Compatibility code: LC1D - Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: bars 1 - busbar cross section: 3 x 16 mm Power circuit: lugs-ring terminals - external diameter: 17 mm - Contactor application: Motor control Resistive load - Control circuit type: DC wide range - Control circuit voltage limits: 0.75...1.2 Uc (-40…55 °C):operational DC 0.1...0.3 Uc (-40…70 °C):drop-out DC 1...1.2 Uc (55…70 °C):operational DC - Device short name: LC1D - Electrical durability: 0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V - Hold-in power consumption in W: 22 W at 20 °C - Inrush power in W: 22 W (at 20 °C) - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947 - Mechanical durability: 10 Mcycles - Motor power hp: 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors - Motor power kW: 22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 22 kW at 220...230 V AC 50/60 Hz (AC-3e) 37 kW at 380...400 V AC 50/60 Hz (AC-3e) 45 kW at 415...440 V AC 50/60 Hz (AC-3e) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 660...690 V AC 50/60 Hz (AC-3e) - Operating time: 95...130 ms closing 20...35 ms opening - Overvoltage category: III - Pole contact composition: 3 NO - Poles description: 3P - Power dissipation per pole: 5.1 W AC-3 12.5 W AC-1 - Product or component type: Contactor - Protective cover: With - Range: TeSys - Range of product: TeSys Deca - Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Tightening torque: Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips - Time constant: 75 ms - Utilisation category: AC-3 AC-3e AC-4 AC-1 - [Icw] rated short-time withstand current: 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit - [Ie] rated operational current: 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit - [Ith] conventional free air thermal current: 10 A (at 60 °C) for signalling circuit 125 A (at 60 °C) for power circuit - [Uc] control circuit voltage: 24 V DC - [Ue] rated operational voltage: Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC - [Ui] rated insulation voltage: Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified - [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947 - pollution degree: 3 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1D806BW with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1D806BW
Brand
Schneider Electric
Part Number
LC1D806BW
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Time constant
75 ms
Characteristic
Value(s)
Motor power hp
7.5 hp at 120 V AC 50/60 Hz for 1 phase motors 15 hp at 230/240 V AC 50/60 Hz for 1 phase motors 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 30 hp at 230/240 V AC 50/60 Hz for 3 phases motors 60 hp at 460/480 V AC 50/60 Hz for 3 phases motors 60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Motor power kW
22 kW at 220...230 V AC 50/60 Hz (AC-3) 37 kW at 380...400 V AC 50/60 Hz (AC-3) 45 kW at 415...440 V AC 50/60 Hz (AC-3) 55 kW at 500 V AC 50/60 Hz (AC-3) 45 kW at 660...690 V AC 50/60 Hz (AC-3) 15 kW at 400 V AC 50/60 Hz (AC-4) 22 kW at 220...230 V AC 50/60 Hz (AC-3e) 37 kW at 380...400 V AC 50/60 Hz (AC-3e) 45 kW at 415...440 V AC 50/60 Hz (AC-3e) 55 kW at 500 V AC 50/60 Hz (AC-3e) 45 kW at 660...690 V AC 50/60 Hz (AC-3e)
Operating time
95...130 ms closing 20...35 ms opening
Coil technology
Without built-in suppressor module
Protective cover
With
Range of product
TeSys Deca
pollution degree
3
Average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Device short name
LC1D
Inrush power in W
22 W (at 20 °C)
Poles description
3P
Tightening torque
Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips
Compatibility code
LC1D
Control circuit type
DC wide range
Overvoltage category
III
Utilisation category
AC-3 AC-3e AC-4 AC-1
Contactor application
Motor control Resistive load
Electrical durability
0.8 Mcycles 125 A AC-1 at Ue <= 440 V 1.5 Mcycles 80 A AC-3 at Ue <= 440 V
Mechanical durability
10 Mcycles
Associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: bars 1 - busbar cross section: 3 x 16 mm Power circuit: lugs-ring terminals - external diameter: 17 mm
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition
3 NO
Safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Product or component type
Contactor
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1100 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
5.1 W AC-3 12.5 W AC-1
[Uc] control circuit voltage
24 V DC
[Ui] rated insulation voltage
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
Control circuit voltage limits
0.75...1.2 Uc (-40…55 °C):operational DC 0.1...0.3 Uc (-40…70 °C):drop-out DC 1...1.2 Uc (55…70 °C):operational DC
Hold-in power consumption in W
22 W at 20 °C
[Ie] rated operational current
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 80 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Ue] rated operational voltage
Power circuit: <= 300 V DC 25...400 Hz Power circuit: <= 690 V AC
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
[Icw] rated short-time withstand current
640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit 135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
[Ith] conventional free air thermal current
10 A (at 60 °C) for signalling circuit 125 A (at 60 °C) for power circuit

Compatibility Information

Match LC1D806BW against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D806BW.

Maintenance Tips

Store LC1D806BW dry and dust-free in its packaging until installation.