+86 13348028050
LC1D80004E5 Schneider Electric LC1D80004E5 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1D80004E5

Product information

SKU: LC1D80004E5

Alternate: LC1D80004E5

Brand
Schneider Electric
Part No.
LC1D80004E5
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1D80004E5 Product overview The Schneider Electric LC1D80004E5 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit - Average impedance: 0.8 mOhm - Ith 125 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Without built-in suppressor module - Compatibility code: LC1D - Connections - terminals: Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end Power circuit: co - Contactor application: Resistive load - Control circuit type: AC 50 Hz - Control circuit voltage limits: 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50 Hz 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz 1...1.1 Uc (131…158 °F (55…70 °C)):operational AC 50 Hz - Device short name: LC1D - Electrical durability: 0.8 Mcycles 125 A AC-1 <= 440 V - Heat dissipation: 6…10 W at 50 Hz - Hold-in power consumption in VA: 20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) - Inrush power in VA: 200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C)) - Irms rated making capacity: 1100 A at 440 V for power circuit conforming to IEC 60947 - Maximum operating rate: 3600 cyc/h at 60 °C - Mechanical durability: 10 Mcycles - Motor power kW: 22 kW at 220...230 V AC 50/60 Hz 37 kW at 380...400 V AC 50/60 Hz 45 kW at 660...690 V AC 50/60 Hz 55 kW at 500 V AC 50/60 Hz 45 kW at 415...440 V AC 50/60 Hz - Operating time: 20...35 ms closing 6...20 ms opening - Overvoltage category: III - Pole contact composition: 4 NO - Poles description: 4P - Power dissipation per pole: 12.5 W AC-1 - Product or Component Type: Contactor - Protective cover: Without - Range: TeSys - Range of Product: TeSys Deca - Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Utilisation category: AC-1 - [Icw] rated short-time withstand current: 640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit - [Ie] rated operational current: 125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit - [Ith] conventional free air thermal current: 125 A (at 140 °F (60 °C)) for power circuit - [Uc] control circuit voltage: 48 V AC 50 Hz - [Ue] rated operational voltage: Power circuit <= 300 V DC 25...400 Hz Power circuit <= 690 V AC - [Ui] rated insulation voltage: Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1 - [Uimp] rated impulse withstand voltage: 8 kV IEC 60947 - pollution degree: 3 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1D80004E5 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1D80004E5
Brand
Schneider Electric
Part Number
LC1D80004E5
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Characteristic
Value(s)
Motor power kW
22 kW at 220...230 V AC 50/60 Hz 37 kW at 380...400 V AC 50/60 Hz 45 kW at 660...690 V AC 50/60 Hz 55 kW at 500 V AC 50/60 Hz 45 kW at 415...440 V AC 50/60 Hz
Operating time
20...35 ms closing 6...20 ms opening
Coil technology
Without built-in suppressor module
Heat dissipation
6…10 W at 50 Hz
Protective cover
Without
Range of Product
TeSys Deca
pollution degree
3
Average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Device short name
LC1D
Poles description
4P
Compatibility code
LC1D
Inrush power in VA
200 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Control circuit type
AC 50 Hz
Overvoltage category
III
Utilisation category
AC-1
Contactor application
Resistive load
Electrical durability
0.8 Mcycles 125 A AC-1 <= 440 V
Mechanical durability
10 Mcycles
Associated fuse rating
200 A gG at <= 690 V coordination type 1 for power circuit 160 A gG at <= 690 V coordination type 2 for power circuit
Maximum operating rate
3600 cyc/h at 60 °C
Connections - terminals
Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: solid without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) - cable stiffness: solid without cable end Power circuit: co
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition
4 NO
Safety reliability level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product or Component Type
Contactor
Irms rated making capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
12.5 W AC-1
[Uc] control circuit voltage
48 V AC 50 Hz
[Ui] rated insulation voltage
Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1
Control circuit voltage limits
0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50 Hz 0.85...1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz 1...1.1 Uc (131…158 °F (55…70 °C)):operational AC 50 Hz
[Ie] rated operational current
125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit
[Ue] rated operational voltage
Power circuit <= 300 V DC 25...400 Hz Power circuit <= 690 V AC
Hold-in power consumption in VA
20 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
[Icw] rated short-time withstand current
640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit 135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit
[Ith] conventional free air thermal current
125 A (at 140 °F (60 °C)) for power circuit

Compatibility Information

Match LC1D80004E5 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D80004E5.

Maintenance Tips

Store LC1D80004E5 dry and dust-free in its packaging until installation.