Schneider Electric LC1D65Q7 Product overview The Schneider Electric LC1D65Q7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for control circuit conforming to IEC 60947-5-1 - Characteristic: Value(s) - Coil technology: Built-in bidirectional peak limiting diode suppressor - Compatibility code: LC1D - Connections - terminals: Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with - Contactor application: Resistive load Motor control - Control circuit type: DC standard - Control circuit voltage limits: 0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz 1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz 0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC - Device short name: LC1D - Hold-in power consumption in VA: 15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) - Hold-in power consumption in W: 7.4 W 68 °F (20 °C) - Inrush power in VA: 160 VA cos phi 0.75 (at 68 °F (20 °C)) - Inrush power in W: 19 W 68 °F (20 °C)) - Irms rated making capacity: 140 A AC for control circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 250 A DC for control circuit conforming to IEC 60947-5-1 - Maximum Horse Power Rating: 10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 40 hp at 460/480 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors 3 hp at 115 V AC 60 Hz for 1 phase motors - Mechanical durability: 10000000 cycles - Motor power kW: 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 380...400 V AC 50 Hz (AC-3) 37 kW at 500 V AC 50 Hz (AC-3) 37 kW at 660...690 V AC 50 Hz (AC-3) 18.5 kW at 220...230 V AC 50 Hz (AC-3) 30 kW at 415 V AC 50 Hz (AC-3) 37 kW at 1000 V AC 50 Hz (AC-3) 25 kW at 415 V AC 50 Hz 22 kW at 380...400 V AC 50 Hz - Operating time: 12...26 ms closing 50 ms closing 20 ms opening - Overvoltage category: III - Pole contact composition: 3 NO - Poles description: 3P - Power dissipation per pole: 6.4 W AC-1 9.6 W AC-1 3.7 W AC-3 - Product or Component Type: Contactor - Protective cover: With - Range: TeSys - Range of Product: TeSys Deca - Rated breaking capacity: 900 A at 440 V for power circuit conforming to IEC 60947 - Rated operational power in W: 12 W 125 V DC-13 10000000 cycles - control circuit 38 W 125 V DC-13 3000000 cycles - control circuit - Safety reliability level: B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 - Time constant: 34 ms - Utilisation category: AC-1 AC-3 AC-2 AC-3 - [Ie] rated operational current: 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit - [Ith] conventional free air thermal current: 80 A (at 140 °F (60 °C)) for power circuit 10 A (at 140 °F (60 °C)) for control circuit - [Uc] control circuit voltage: 125 V DC - [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz - [Ui] rated insulation voltage: Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL IEC 60947-1 Control circuit 690 V IEC 60947-1 Power circuit 690 V CSA IEC 60947-1 Control circuit 600 V CSA - [Uimp] rated impulse withstand voltage: 8 kV IEC 60947 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1D65Q7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1D65Q7
Brand
Schneider Electric
Part Number
LC1D65Q7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Time constant
34 ms
Characteristic
Value(s)
Motor power kW
11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 380...400 V AC 50 Hz (AC-3) 37 kW at 500 V AC 50 Hz (AC-3) 37 kW at 660...690 V AC 50 Hz (AC-3) 18.5 kW at 220...230 V AC 50 Hz (AC-3) 30 kW at 415 V AC 50 Hz (AC-3) 37 kW at 1000 V AC 50 Hz (AC-3) 25 kW at 415 V AC 50 Hz 22 kW at 380...400 V AC 50 Hz
Operating time
12...26 ms closing 50 ms closing 20 ms opening
Coil technology
Built-in bidirectional peak limiting diode suppressor
Protective cover
With
Range of Product
TeSys Deca
Device short name
LC1D
Inrush power in W
19 W 68 °F (20 °C))
Poles description
3P
Compatibility code
LC1D
Inrush power in VA
160 VA cos phi 0.75 (at 68 °F (20 °C))
Control circuit type
DC standard
Overvoltage category
III
Utilisation category
AC-1 AC-3 AC-2 AC-3
Contactor application
Resistive load Motor control
Mechanical durability
10000000 cycles
Associated fuse rating
125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1 100 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for control circuit conforming to IEC 60947-5-1
Connections - terminals
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) - cable stiffness: flexible with
Rated breaking capacity
900 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition
3 NO
Safety reliability level
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Product or Component Type
Contactor
Irms rated making capacity
140 A AC for control circuit conforming to IEC 60947-5-1 900 A at 440 V for power circuit conforming to IEC 60947 250 A DC for control circuit conforming to IEC 60947-5-1
Maximum Horse Power Rating
10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 40 hp at 460/480 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors 3 hp at 115 V AC 60 Hz for 1 phase motors
Power dissipation per pole
6.4 W AC-1 9.6 W AC-1 3.7 W AC-3
Rated operational power in W
12 W 125 V DC-13 10000000 cycles - control circuit 38 W 125 V DC-13 3000000 cycles - control circuit
[Uc] control circuit voltage
125 V DC
[Ui] rated insulation voltage
Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL IEC 60947-1 Control circuit 690 V IEC 60947-1 Power circuit 690 V CSA IEC 60947-1 Control circuit 600 V CSA
Control circuit voltage limits
0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz 1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz 0.75...1.25 Uc (-40…140 °F (-40…60 °C)):operational DC 0.1...0.3 Uc (-40…158 °F (-40…70 °C)):drop-out DC
Hold-in power consumption in W
7.4 W 68 °F (20 °C)
[Ie] rated operational current
65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit 50 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
Hold-in power consumption in VA
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
[Uimp] rated impulse withstand voltage
8 kV IEC 60947
[Ith] conventional free air thermal current
80 A (at 140 °F (60 °C)) for power circuit 10 A (at 140 °F (60 °C)) for control circuit

Compatibility Information

Match LC1D65Q7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D65Q7.

Maintenance Tips

Store LC1D65Q7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options