+86 13348028050
LC1D65B7 Schneider Electric LC1D65B7 - Front View | Vcocnc FANUC Parts

Schneider Electric LC1D65B7

Product information

$1,145.45 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: LC1D65B7

Alternate: LC1D65B7

Brand
Schneider Electric
Part No.
LC1D65B7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric LC1D65B7 Product overview The Schneider Electric LC1D65B7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 125 A gG at <= 690 V coordination type 2 for power circuit 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for control circuit conforming to IEC 60947-5-1 - Average impedance: 1.5 Ohm - Ith 80 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: Without built-in - Compatibility code: LC1D - Connections - terminals: Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) - - Contactor application: Resistive load Motor control - Control circuit type: AC 50/60 Hz - Control circuit voltage limits: 0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz 1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz - Device short name: LC1D - Heat dissipation: 4…5 W at 50/60 Hz for control circuit - Hold-in power consumption in VA: 15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C)) - Inrush power in VA: 160 VA cos phi 0.75 (at 68 °F (20 °C)) 140 VA cos phi 0.75 (at 68 °F (20 °C)) - Irms rated making capacity: 140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 140 A AC for control circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 - Maximum Horse Power Rating: 10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 40 hp at 460/480 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors 5 hp at 115 V AC 60 Hz for 1 phase motors - Maximum operating rate: 3600 cyc/mn at 60 °C - Mechanical durability: 6000000 cycles - Motor power kW: 11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 380...400 V AC 50 Hz (AC-3) 37 kW at 500 V AC 50 Hz (AC-3) 37 kW at 660...690 V AC 50 Hz (AC-3) 18.5 kW at 220...230 V AC 50 Hz (AC-3) 30 kW at 415 V AC 50 Hz (AC-3) 37 kW at 1000 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3e) 30 kW at 380...400 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz (AC-3e) 37 kW at 660...690 V AC 50 Hz (AC-3e) 18.5 kW at 220...230 V AC 50 Hz (AC-3e) 30 kW at 415 V AC 50 Hz (AC-3e) 37 kW at 1000 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz 30 kW at 380...400 V AC 50 Hz - Operating time: 12...26 ms closing 4...19 ms opening - Overvoltage category: III - Pole contact composition: 3 NO - Poles description: 3P - Power dissipation per pole: 6.4 W AC-1 4.2 W AC-3e 6.3 W AC-3 9.6 W AC-1 - Product or Component Type: Contactor - Protective cover: With - Range: TeSys - Range of Product: TeSys Deca - Rated breaking capacity: 1000 kA at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 - Utilisation category: AC-4 AC-1 AC-2 AC-3e AC-1 - [Icw] rated short-time withstand current: 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit - [Ie] rated operational current: 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 65 A (at <140 °F (60 °C)) at 24 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at 24 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 80 A (at 140 °F (60 °C)) for power circuit 10 A (at 140 °F (60 °C)) for control circuit - [Uc] control circuit voltage: 24 V AC 50/60 Hz - [Ue] rated operational voltage: Power circuit <= 690 V AC 25...400 Hz - [Ui] rated insulation voltage: Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL IEC 60947-1 Control circuit 690 V IEC 60947-1 Power circuit 690 V CSA IEC 60947-1 Control circuit 600 V CSA - [Uimp] rated impulse withstand voltage: 6 kV IEC 60947 Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1D65B7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1D65B7
Brand
Schneider Electric
Part Number
LC1D65B7
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Characteristic
Value(s)
Motor power kW
11 kW at 400 V AC 50 Hz (AC-4) 30 kW at 380...400 V AC 50 Hz (AC-3) 37 kW at 500 V AC 50 Hz (AC-3) 37 kW at 660...690 V AC 50 Hz (AC-3) 18.5 kW at 220...230 V AC 50 Hz (AC-3) 30 kW at 415 V AC 50 Hz (AC-3) 37 kW at 1000 V AC 50 Hz (AC-3) 30 kW at 440 V AC 50 Hz (AC-3e) 30 kW at 380...400 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz (AC-3e) 37 kW at 660...690 V AC 50 Hz (AC-3e) 18.5 kW at 220...230 V AC 50 Hz (AC-3e) 30 kW at 415 V AC 50 Hz (AC-3e) 37 kW at 1000 V AC 50 Hz (AC-3e) 37 kW at 500 V AC 50 Hz 30 kW at 380...400 V AC 50 Hz
Operating time
12...26 ms closing 4...19 ms opening
Coil technology
Without built-in
Heat dissipation
4…5 W at 50/60 Hz for control circuit
Protective cover
With
Range of Product
TeSys Deca
Average impedance
1.5 Ohm - Ith 80 A 50 Hz for power circuit
Device short name
LC1D
Poles description
3P
Compatibility code
LC1D
Inrush power in VA
160 VA cos phi 0.75 (at 68 °F (20 °C)) 140 VA cos phi 0.75 (at 68 °F (20 °C))
Control circuit type
AC 50/60 Hz
Overvoltage category
III
Utilisation category
AC-4 AC-1 AC-2 AC-3e AC-1
Contactor application
Resistive load Motor control
Mechanical durability
6000000 cycles
Associated fuse rating
125 A gG at <= 690 V coordination type 2 for power circuit 160 A gG at <= 690 V coordination type 1 for power circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 10 A gG for control circuit conforming to IEC 60947-5-1
Maximum operating rate
3600 cyc/mn at 60 °C
Connections - terminals
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) - cable stiffness: rigid without cable end Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) -
Rated breaking capacity
1000 kA at 440 V for power circuit conforming to IEC 60947
Pole contact composition
3 NO
Safety reliability level
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product or Component Type
Contactor
Irms rated making capacity
140 A at 440 V AC for control circuit conforming to IEC 60947-5-1 140 A AC for control circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947
Maximum Horse Power Rating
10 hp at 230/240 V AC 60 Hz for 1 phase motors 20 hp at 200/208 V AC 60 Hz for 3 phase motors 20 hp at 230/240 V AC 60 Hz for 3 phase motors 40 hp at 460/480 V AC 60 Hz for 3 phase motors 50 hp at 575/600 V AC 60 Hz for 3 phase motors 5 hp at 115 V AC 60 Hz for 1 phase motors
Power dissipation per pole
6.4 W AC-1 4.2 W AC-3e 6.3 W AC-3 9.6 W AC-1
[Uc] control circuit voltage
24 V AC 50/60 Hz
[Ui] rated insulation voltage
Control circuit 600 V UL Power circuit 600 V CSA Power circuit 600 V UL IEC 60947-1 Control circuit 690 V IEC 60947-1 Power circuit 690 V CSA IEC 60947-1 Control circuit 600 V CSA
Control circuit voltage limits
0.8...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 50 Hz 0.85...1.1 Uc (-40…140 °F (-40…60 °C)):operational AC 60 Hz 1...1.1 Uc (140…158 °F (60…70 °C)):operational AC 50/60 Hz 0.3...0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
[Ie] rated operational current
65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit 65 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit 65 A (at <140 °F (60 °C)) at 24 V AC AC-3 for power circuit 80 A (at <140 °F (60 °C)) at 24 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit <= 690 V AC 25...400 Hz
Hold-in power consumption in VA
15 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C)) 13 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
[Uimp] rated impulse withstand voltage
6 kV IEC 60947
[Icw] rated short-time withstand current
520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit
[Ith] conventional free air thermal current
80 A (at 140 °F (60 °C)) for power circuit 10 A (at 140 °F (60 °C)) for control circuit

Compatibility Information

Match LC1D65B7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D65B7.

Maintenance Tips

Store LC1D65B7 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options