Schneider Electric LC1D1156Q7
Product information
$663.30 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: LC1D1156Q7
Alternate: LC1D1156Q7
Brand
Schneider Electric
Part No.
LC1D1156Q7
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric LC1D1156Q7
Product overview
The Schneider Electric LC1D1156Q7 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Associated fuse rating: 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit
- Average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Characteristic: Value(s)
- Coil technology: Built-in bidirectional peak limiting diode suppressor
- Compatibility code: LC1D
- Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 25 mm Power circuit: bars 1 - busbar cross section: 5 x 25 mm
- Contactor application: Motor control Resistive load
- Control circuit type: AC at 50/60 Hz
- Control circuit voltage limits: 0.3...0.5 Uc (-40â¦70 °C):drop-out AC 50/60 Hz 0.8...1.15 Uc (-40â¦55 °C):operational AC 50/60 Hz 1...1.15 Uc (55â¦70 °C):operational AC 50/60 Hz
- Device short name: LC1D
- Electrical durability: 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V 0.95 Mcycles 115 A AC-3e at Ue <= 440 V
- Heat dissipation: 3â¦8 W at 50/60 Hz
- Hold-in power consumption in VA: 2â¦18 VA 60 Hz cos phi 0.3 (at 20 °C) 2â¦18 VA 50 Hz cos phi 0.3 (at 20 °C)
- Inrush power in VA: 280â¦350 VA 60 Hz cos phi 0.8 (at 20 °C) 280â¦350 VA 50 Hz cos phi 0.8 (at 20 °C)
- Irms rated making capacity: 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Mechanical durability: 8 Mcycles
- Motor power hp: 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- Motor power kW: 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) 30 kW at 220...230 V AC 50/60 Hz (AC-3e) 55 kW at 380...400 V AC 50/60 Hz (AC-3e) 59 kW at 415...440 V AC 50/60 Hz (AC-3e) 75 kW at 500 V AC 50/60 Hz (AC-3e) 80 kW at 660...690 V AC 50/60 Hz (AC-3e) 65 kW at 1000 V AC 50/60 Hz (AC-3e)
- Operating time: 6...20 ms opening 20...50 ms closing
- Overvoltage category: III
- Pole contact composition: 3 NO
- Poles description: 3P
- Power dissipation per pole: 24 W AC-1 7.9 W AC-3 7.9 W AC-3e
- Product or component type: Contactor
- Protective cover: With
- Range: TeSys
- Range of product: TeSys Deca
- Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
- Safety reliability level: B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Utilisation category: AC-4 AC-1 AC-3 AC-3e
- [Icw] rated short-time withstand current: 250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
- [Ie] rated operational current: 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- [Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit
- [Uc] control circuit voltage: 380 V AC 50/60 Hz
- [Ue] rated operational voltage: Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC
- [Ui] rated insulation voltage: Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
- [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
- pollution degree: 3
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number LC1D1156Q7 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- LC1D1156Q7
- Brand
- Schneider Electric
- Part Number
- LC1D1156Q7
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Range
- TeSys
- Packaging
- New surplus, never used
- Characteristic
- Value(s)
- Motor power hp
- 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
- Motor power kW
- 30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4) 30 kW at 220...230 V AC 50/60 Hz (AC-3e) 55 kW at 380...400 V AC 50/60 Hz (AC-3e) 59 kW at 415...440 V AC 50/60 Hz (AC-3e) 75 kW at 500 V AC 50/60 Hz (AC-3e) 80 kW at 660...690 V AC 50/60 Hz (AC-3e) 65 kW at 1000 V AC 50/60 Hz (AC-3e)
- Operating time
- 6...20 ms opening 20...50 ms closing
- Coil technology
- Built-in bidirectional peak limiting diode suppressor
- Heat dissipation
- 3â¦8 W at 50/60 Hz
- Protective cover
- With
- Range of product
- TeSys Deca
- pollution degree
- 3
- Average impedance
- 0.6 mOhm - Ith 200 A 50 Hz for power circuit
- Device short name
- LC1D
- Poles description
- 3P
- Compatibility code
- LC1D
- Inrush power in VA
- 280â¦350 VA 60 Hz cos phi 0.8 (at 20 °C) 280â¦350 VA 50 Hz cos phi 0.8 (at 20 °C)
- Control circuit type
- AC at 50/60 Hz
- Overvoltage category
- III
- Utilisation category
- AC-4 AC-1 AC-3 AC-3e
- Contactor application
- Motor control Resistive load
- Electrical durability
- 0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V 0.95 Mcycles 115 A AC-3e at Ue <= 440 V
- Mechanical durability
- 8 Mcycles
- Associated fuse rating
- 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit
- Connections - terminals
- Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 25 mm Power circuit: bars 1 - busbar cross section: 5 x 25 mm
- Rated breaking capacity
- 1100 A at 440 V for power circuit conforming to IEC 60947
- Pole contact composition
- 3 NO
- Safety reliability level
- B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Product or component type
- Contactor
- Irms rated making capacity
- 1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
- Power dissipation per pole
- 24 W AC-1 7.9 W AC-3 7.9 W AC-3e
- [Uc] control circuit voltage
- 380 V AC 50/60 Hz
- [Ui] rated insulation voltage
- Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
- Control circuit voltage limits
- 0.3...0.5 Uc (-40â¦70 °C):drop-out AC 50/60 Hz 0.8...1.15 Uc (-40â¦55 °C):operational AC 50/60 Hz 1...1.15 Uc (55â¦70 °C):operational AC 50/60 Hz
- [Ie] rated operational current
- 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit 115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
- [Ue] rated operational voltage
- Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC
- Hold-in power consumption in VA
- 2â¦18 VA 60 Hz cos phi 0.3 (at 20 °C) 2â¦18 VA 50 Hz cos phi 0.3 (at 20 °C)
- [Uimp] rated impulse withstand voltage
- 8 kV conforming to IEC 60947
- [Icw] rated short-time withstand current
- 250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
- [Ith] conventional free air thermal current
- 200 A (at 60 °C) for power circuit
Compatibility Information
Match LC1D1156Q7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D1156Q7.
Maintenance Tips
Store LC1D1156Q7 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. LC1D1156Q7 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
LC1D1156Q7 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match LC1D1156Q7 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW
SKU: ZMLPA1P2SW