Schneider Electric LC1D1150046MD Product overview The Schneider Electric LC1D1150046MD is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Associated fuse rating: 250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit - Average impedance: 0.6 mOhm - Ith 200 A 50 Hz for power circuit - Characteristic: Value(s) - Coil technology: With integral suppression device - Compatibility code: LC1D - Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 25 mm Power circuit: bars 1 - busbar cross section: 5 x 25 mm - Contactor application: Resistive load - Control circuit type: DC standard - Control circuit voltage limits: 0.75...1.2 Uc (-40…55 °C):operational DC 0.15...0.4 Uc (-40…70 °C):drop-out DC 1...1.2 Uc (55…70 °C):operational DC - Device short name: LC1D - Electrical durability: 0.8 Mcycles 200 A AC-1 at Ue <= 440 V - Hold-in power consumption in W: 2.4…5.1 W at 20 °C - Inrush power in W: 270…365 W (at 20 °C) - Irms rated making capacity: 1260 A at 440 V for power circuit conforming to IEC 60947 - Mechanical durability: 8 Mcycles - Mounting support: Rail Plate - Operating time: 20...35 ms closing 40...75 ms opening - Overvoltage category: III - Pole contact composition: 4 NO - Poles description: 4P - Power dissipation per pole: 24 W AC-1 - Product or component type: Contactor - Protective cover: With - Range: TeSys - Range of product: TeSys Deca - Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947 - Safety reliability level: B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - Tightening torque: Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8 Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5 - Time constant: 25 ms - Utilisation category: AC-1 AC-3 AC-3e AC-4 - [Icw] rated short-time withstand current: 250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit - [Ie] rated operational current: 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit - [Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit - [Uc] control circuit voltage: 220 V DC - [Ue] rated operational voltage: Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 460 V DC - [Ui] rated insulation voltage: Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 - [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947 - pollution degree: 3 Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number LC1D1150046MD with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
LC1D1150046MD
Brand
Schneider Electric
Part Number
LC1D1150046MD
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Range
TeSys
Packaging
New surplus, never used
Time constant
25 ms
Characteristic
Value(s)
Operating time
20...35 ms closing 40...75 ms opening
Coil technology
With integral suppression device
Mounting support
Rail Plate
Protective cover
With
Range of product
TeSys Deca
pollution degree
3
Average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Device short name
LC1D
Inrush power in W
270…365 W (at 20 °C)
Poles description
4P
Tightening torque
Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 13 mm M8 Power circuit: 12 N.m - on bars hexagonal screw head 13 mm M8 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5
Compatibility code
LC1D
Control circuit type
DC standard
Overvoltage category
III
Utilisation category
AC-1 AC-3 AC-3e AC-4
Contactor application
Resistive load
Electrical durability
0.8 Mcycles 200 A AC-1 at Ue <= 440 V
Mechanical durability
8 Mcycles
Associated fuse rating
250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit
Connections - terminals
Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 25 mm Power circuit: bars 1 - busbar cross section: 5 x 25 mm
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition
4 NO
Safety reliability level
B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Product or component type
Contactor
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947
Power dissipation per pole
24 W AC-1
[Uc] control circuit voltage
220 V DC
[Ui] rated insulation voltage
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1
Control circuit voltage limits
0.75...1.2 Uc (-40…55 °C):operational DC 0.15...0.4 Uc (-40…70 °C):drop-out DC 1...1.2 Uc (55…70 °C):operational DC
Hold-in power consumption in W
2.4…5.1 W at 20 °C
[Ie] rated operational current
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 460 V DC
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
[Icw] rated short-time withstand current
250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit
[Ith] conventional free air thermal current
200 A (at 60 °C) for power circuit

Compatibility Information

Match LC1D1150046MD against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing LC1D1150046MD.

Maintenance Tips

Store LC1D1150046MD dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options