+86 13348028050
KV-XH04ML KEYENCE KV-XH04ML - Front View | Vcocnc FANUC Parts

KEYENCE KV-XH04ML

Product information

$567.99 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: KV-XH04ML

Alternate: KVXH04ML

Brand
KEYENCE
Part No.
KV-XH04ML
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE KV-XH04ML Product overview The KEYENCE KV-XH04ML is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Acceleration/deceleration curve: Linear, SIN - Acceleration/deceleration time: 0 to 65535 ms - Appropriated device: Relay: 576 points (36 channels) Data memory: 4 words - Axis control function execution method: Ladder program, unit program (flow) - Cam: Resolution: 2048 to 32768, Data points: 4 to 64 (changes according to the resolution) - Clutch: Select from direct, slide, and follow-up - Compensation during operation: Compensation via auxiliary input, phase compensation, and step angle compensation - Connectable CPU unit: KV-X Series/KV-8000A - Control mode: Positioning control, Torque control, Speed control, ML-III command, I/O control - Control period: 500 μs or more - Cumulative address: -2147483648 to +2147483647 specification units - Flow / Block type: Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block - Flow / Internal data Memory: 524288 words - Input filter: Interference prevention function - Interpolation: Linear interpolation, arc interpolation, helical interpolation - JOG/inching: JOG (high speed/low speed), inching (specifiable pulses) - M-code: 1 to 65000, WITH/AFTER mode - Max. number of connectable units: 16 - Memory data: Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters, setting read/write during RUN (with some restrictions) - No. of control axes: 4 axes (total including virtual axes) - Number of points: 100 points/axis (Trajectory control at 100 points or more possible with flows) - Number of simultaneous activities: No upper limit - Origin return / Origin return method: Data set type, dog type (push), dog type (selectable from “with Z phase” or “without Z phase”), dog type sizing (selectable from “with Z phase” or “without Z phase”), immediate Z phase, origin sensor and Z phase, rising edge of limit switch, origin sensor midpoint/rising edge - Output display: LINK, CONNECT, error status - Output format: MECHATROLINK-III - Parameter setting: Parameters can be set from KV STUDIO, ladder programs, and unit programs - Position setting range: -2147483648 to +2147483647 specification units - Position unit: mm, inch, deg (angle), PLS (number of pulses) - Positioning control / Positioning mode: Absolute value/relative value - Refresh: Automatic refresh, direct refresh, synchronous refresh between units - Self-diagnosis function: Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages - Sensor positioning: External input-based switching control from speed to position - Single operation address: -2147483648 to +2147483647 specification units - Special function: Synchronous tracking control, absolute position tracking control - Starting time: 500 μs - Synchronization control / Input: External reference, instruction coordinates, current coordinates - Teaching: Current coordinate teaching - Type: Positioning/Motion unit - Unit program capacity: 3 MB (Max. number of blocks: 20000) - flow / Max. number of flows: 256 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number KV-XH04ML with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
KV-XH04ML
Brand
KEYENCE
Part Number
KV-XH04ML
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Cam
Resolution: 2048 to 32768, Data points: 4 to 64 (changes according to the resolution)
Type
Positioning/Motion unit
Clutch
Select from direct, slide, and follow-up
M-code
1 to 65000, WITH/AFTER mode
Refresh
Automatic refresh, direct refresh, synchronous refresh between units
Teaching
Current coordinate teaching
Packaging
New surplus, factory sealed original packaging
JOG/inching
JOG (high speed/low speed), inching (specifiable pulses)
Memory data
Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters, setting read/write during RUN (with some restrictions)
Control mode
Positioning control, Torque control, Speed control, ML-III command, I/O control
Input filter
Interference prevention function
Interpolation
Linear interpolation, arc interpolation, helical interpolation
Output format
MECHATROLINK-III
Position unit
mm, inch, deg (angle), PLS (number of pulses)
Starting time
500 μs
Control period
500 μs or more
Output display
LINK, CONNECT, error status
Number of points
100 points/axis (Trajectory control at 100 points or more possible with flows)
Special function
Synchronous tracking control, absolute position tracking control
Flow / Block type
Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block
Parameter setting
Parameters can be set from KV STUDIO, ladder programs, and unit programs
Cumulative address
-2147483648 to +2147483647 specification units
Sensor positioning
External input-based switching control from speed to position
Appropriated device
Relay: 576 points (36 channels) Data memory: 4 words
No. of control axes
4 axes (total including virtual axes)
Connectable CPU unit
KV-X Series/KV-8000A
Unit program capacity
3 MB (Max. number of blocks: 20000)
Position setting range
-2147483648 to +2147483647 specification units
Self-diagnosis function
Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages
Single operation address
-2147483648 to +2147483647 specification units
Flow / Internal data Memory
524288 words
flow / Max. number of flows
256
Compensation during operation
Compensation via auxiliary input, phase compensation, and step angle compensation
Acceleration/deceleration time
0 to 65535 ms
Acceleration/deceleration curve
Linear, SIN
Synchronization control / Input
External reference, instruction coordinates, current coordinates
Max. number of connectable units
16
Number of simultaneous activities
No upper limit
Origin return / Origin return method
Data set type, dog type (push), dog type (selectable from “with Z phase” or “without Z phase”), dog type sizing (selectable from “with Z phase” or “without Z phase”), immediate Z phase, origin sensor and Z phase, rising edge of limit switch, origin sensor midpoint/rising edge
Axis control function execution method
Ladder program, unit program (flow)
Positioning control / Positioning mode
Absolute value/relative value

Compatibility Information

Match KV-XH04ML against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing KV-XH04ML.

Maintenance Tips

Store KV-XH04ML dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114