+86 13348028050
KV-TP40 KEYENCE KV-TP40 - Front View | Vcocnc FANUC Parts

KEYENCE KV-TP40

Product information

$342.32 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: KV-TP40

Alternate: KVTP40

Brand
KEYENCE
Part No.
KV-TP40
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE KV-TP40 Product overview The KEYENCE KV-TP40 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Cold junction correction precision: ±1°C ±1.8°F (during thermocouple input) - Conversion speed: 50 ms/4 ch - Indicated accuracy: ±0.2% of F.S. (at 25°C ±5°C 77°F ±9°F ), ±0.4% of F.S. (at 0 to 50°C 32 to 122°F ) - Input: Thermocoupler/Platinum temperature measuring resistor/Voltage and current - Input range / Thermocoupler: K: -270.0 to 1372.0°C -454 to 2502°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214°F S: -50.0 to 1768.0°C -58 to 3214°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F - Input resistance: Voltage: 1 MΩ, Current: 250 Ω - Insulation mode: Between an input terminal and CPU: Photocoupler and transformer insulation, Between channels: Photocoupler and transformer insulation - Internal current consumption: 90 mA or less - Number of temperature input points: 4 ch - Others: External cold junction correction, wire-breaking detection function, scaling function, average processing function (time average, average of the number of times, moving average, primary delay filter), special data offset function, alarm function, rate of change calculation, rate of change alarm function - Platinum temperature measuring resistor: Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F - Type: Temperature/Analog multi-input unit - Voltage and current: Voltage: -10 to +10 V (0.5 mV 1/40000) 0 V to 10 V (0.5 mV 1/20000) -5 V to +5 V (0.5 mV 1/20000) 0 V to 5 V (0.5 mV 1/10000) 1 V to 5 V (0.5 mV 1/8000) -100 mV to +100 mV (5 μV 1/40000) 0 mV to 100 mV (5 μV 1/20000) Current: 0 mA to 20 mA (2 μA 1/10000) 4 mA to 20 mA (2 μA 1/8000) - Weight: Approx. 190 g Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number KV-TP40 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
KV-TP40
Brand
KEYENCE
Part Number
KV-TP40
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Temperature/Analog multi-input unit
Input
Thermocoupler/Platinum temperature measuring resistor/Voltage and current
Others
External cold junction correction, wire-breaking detection function, scaling function, average processing function (time average, average of the number of times, moving average, primary delay filter), special data offset function, alarm function, rate of change calculation, rate of change alarm function
Weight
Approx. 190 g
Packaging
New surplus, factory sealed original packaging
Insulation mode
Between an input terminal and CPU: Photocoupler and transformer insulation, Between channels: Photocoupler and transformer insulation
Conversion speed
50 ms/4 ch
Input resistance
Voltage: 1 MΩ, Current: 250 Ω
Indicated accuracy
±0.2% of F.S. (at 25°C ±5°C 77°F ±9°F ), ±0.4% of F.S. (at 0 to 50°C 32 to 122°F )
Voltage and current
Voltage: -10 to +10 V (0.5 mV 1/40000) 0 V to 10 V (0.5 mV 1/20000) -5 V to +5 V (0.5 mV 1/20000) 0 V to 5 V (0.5 mV 1/10000) 1 V to 5 V (0.5 mV 1/8000) -100 mV to +100 mV (5 μV 1/40000) 0 mV to 100 mV (5 μV 1/20000) Current: 0 mA to 20 mA (2 μA 1/10000) 4 mA to 20 mA (2 μA 1/8000)
Input range / Thermocoupler
K: -270.0 to 1372.0°C -454 to 2502°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214°F S: -50.0 to 1768.0°C -58 to 3214°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F
Internal current consumption
90 mA or less
Cold junction correction precision
±1°C ±1.8°F (during thermocouple input)
Number of temperature input points
4 ch
Platinum temperature measuring resistor
Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F

Compatibility Information

Match KV-TP40 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing KV-TP40.

Maintenance Tips

Store KV-TP40 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.