Product Description

KEYENCE KV-NC4TP Product overview The KEYENCE KV-NC4TP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - (When resistance thermometer is used): No isolation - Allowable wiring resistance: 100 Ω max./wire (no variation allowed among three wires) - Conversion speed: 125 ms/channel - Input: Thermocouple, Platinum resistance thermometer - Input range / Thermocouple: K: -270.0 to 1372.0°C -454 to 2501.6°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214.4°F S: -50.0 to 1768.0°C -58 to 3214.4°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F - Internal current consumption: 40 mA or less - Isolation method: Between input terminals and base unit: Photocoupler/semiconductor relay/transformer isolation Between channels: (When resistance thermometer is not used): Semiconductor relay isolation - Overall accuracy / Thermocouple: ±(0.2% of F.S. +1°C 1.8°F ) (at 25°C ±5°C 77°F ±9°F ) ±(0.4% of F.S. +1°C 1.8°F ) (at 0 to 55°C 32 to 131°F ) - Platinum resistance thermometer: Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F - Special function: Channel skip, disconnection detection, averaging (time average, count average, moving average), special data offset, peak-/bottom-hold, alarm, abnormal input setting - Temperature input unit / Number of inputs: 4 *1 - Weight: Approx. 110 g Condition and supply - New surplus, never used - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number KV-NC4TP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
KV-NC4TP
Brand
KEYENCE
Part Number
KV-NC4TP
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Input
Thermocouple, Platinum resistance thermometer
Weight
Approx. 110 g
Packaging
New surplus, never used
Conversion speed
125 ms/channel
Isolation method
Between input terminals and base unit: Photocoupler/semiconductor relay/transformer isolation Between channels: (When resistance thermometer is not used): Semiconductor relay isolation
Special function
Channel skip, disconnection detection, averaging (time average, count average, moving average), special data offset, peak-/bottom-hold, alarm, abnormal input setting
Input range / Thermocouple
K: -270.0 to 1372.0°C -454 to 2501.6°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214.4°F S: -50.0 to 1768.0°C -58 to 3214.4°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F
Allowable wiring resistance
100 Ω max./wire (no variation allowed among three wires)
Internal current consumption
40 mA or less
Overall accuracy / Thermocouple
±(0.2% of F.S. +1°C 1.8°F ) (at 25°C ±5°C 77°F ±9°F ) ±(0.4% of F.S. +1°C 1.8°F ) (at 0 to 55°C 32 to 131°F )
Platinum resistance thermometer
Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F
(When resistance thermometer is used)
No isolation
Temperature input unit / Number of inputs
4 *1

Compatibility Information

Match KV-NC4TP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing KV-NC4TP.

Maintenance Tips

Store KV-NC4TP dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114