KEYENCE KV-NC4TP
Product information
$665.59 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: KV-NC4TP
Alternate: KVNC4TP
Brand
KEYENCE
Part No.
KV-NC4TP
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE KV-NC4TP
Product overview
The KEYENCE KV-NC4TP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- (When resistance thermometer is used): No isolation
- Allowable wiring resistance: 100 Ω max./wire (no variation allowed among three wires)
- Conversion speed: 125 ms/channel
- Input: Thermocouple, Platinum resistance thermometer
- Input range / Thermocouple: K: -270.0 to 1372.0°C -454 to 2501.6°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214.4°F S: -50.0 to 1768.0°C -58 to 3214.4°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F
- Internal current consumption: 40 mA or less
- Isolation method: Between input terminals and base unit: Photocoupler/semiconductor relay/transformer isolation Between channels: (When resistance thermometer is not used): Semiconductor relay isolation
- Overall accuracy / Thermocouple: ±(0.2% of F.S. +1°C 1.8°F ) (at 25°C ±5°C 77°F ±9°F ) ±(0.4% of F.S. +1°C 1.8°F ) (at 0 to 55°C 32 to 131°F )
- Platinum resistance thermometer: Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F
- Special function: Channel skip, disconnection detection, averaging (time average, count average, moving average), special data offset, peak-/bottom-hold, alarm, abnormal input setting
- Temperature input unit / Number of inputs: 4 *1
- Weight: Approx. 110 g
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number KV-NC4TP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- KV-NC4TP
- Brand
- KEYENCE
- Part Number
- KV-NC4TP
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Input
- Thermocouple, Platinum resistance thermometer
- Weight
- Approx. 110 g
- Packaging
- New surplus, never used
- Conversion speed
- 125 ms/channel
- Isolation method
- Between input terminals and base unit: Photocoupler/semiconductor relay/transformer isolation Between channels: (When resistance thermometer is not used): Semiconductor relay isolation
- Special function
- Channel skip, disconnection detection, averaging (time average, count average, moving average), special data offset, peak-/bottom-hold, alarm, abnormal input setting
- Input range / Thermocouple
- K: -270.0 to 1372.0°C -454 to 2501.6°F J: -210.0 to 1200.0°C -346 to 2192°F T: -270.0 to 400.0°C -454 to 752°F E: -270.0 to 1000.0°C -454 to 1832°F N: -270.0 to 1300.0°C -454 to 2372°F R: -50.0 to 1768.0°C -58 to 3214.4°F S: -50.0 to 1768.0°C -58 to 3214.4°F B: 0.0 to 1820.0°C 32 to 3308°F WRe5-26: 0.0 to 2315.0°C 32 to 4199°F
- Allowable wiring resistance
- 100 Ω max./wire (no variation allowed among three wires)
- Internal current consumption
- 40 mA or less
- Overall accuracy / Thermocouple
- ±(0.2% of F.S. +1°C 1.8°F ) (at 25°C ±5°C 77°F ±9°F ) ±(0.4% of F.S. +1°C 1.8°F ) (at 0 to 55°C 32 to 131°F )
- Platinum resistance thermometer
- Pt100: -200.0 to 850.0°C -328 to 1562°F JPt100: -200.0 to 600.0°C -328 to 1112°F
- (When resistance thermometer is used)
- No isolation
- Temperature input unit / Number of inputs
- 4 *1
Compatibility Information
Match KV-NC4TP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing KV-NC4TP.
Maintenance Tips
Store KV-NC4TP dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. KV-NC4TP is in stock and ships within 1-2 business days, with a tracking number for every shipment.
KV-NC4TP is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match KV-NC4TP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114