Product overview
The KEYENCE KV-NC1EP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Clock data automatic adjustment: No. of sockets UDP: 1 Port No.: 123
- DNS: No. of sockets UDP: 1 Port No.: 53
- Easy PLC link: No. of sockets UDP: 1 Port No.: 5001 (can be set within the range between 1 and 65535)
- EtherNet/IP™ conformance test: Conforming to CT10
- EtherNet/IP™ cyclic communication function: No. of sockets TCP: Total: 320 UDP: 1 Port No.: 2222
- EtherNet/IP™ message communication function: No. of sockets TCP: Total: 320 UDP: 1 Port No.: 44818
- EtherNet/IP™ unit (communication specifications) / CIP service: Cyclic communication Number of connections 64 *2
- EtherNet/IP™ unit (performance specifications) / PC applications: No. of sockets TCP: 8 UDP: 0 Port No.: 8500 (can be set within the range between 1 and 65535) *8
- FTP client: No. of sockets TCP: 2 Port No.: 20, 21 (can be set within the range between 1 and 65535)
- FTP server: No. of sockets TCP: 4 Port No.: 20, 21
- Host link communication: No. of sockets TCP: Total: 15 UDP: 1 Port No.: 8501 (can be set within the range between 1 and 65535) *9 *10
- Internal current consumption: 90 mA or less
- MC protocol communication: No. of sockets TCP: Total: 15 UDP: 1 Port No.: 5000 (can be set within the range between 1 and 65535) *11 *9 *10
- Maximum data size per connection: 504 bytes or 1444 bytes *5
- Maximum number of refresh words: 8000 words
- Message communication / Class 3 (connection type): Server: No. of connections: 64 *7
- Multicast filter function: Provided (IGMP client function) *6
- RP I (communication cycle): 0.5 to 10000 ms (0.5 ms increments) Setting is possible for each connection. (Data is updated on the line at specified cycles, independent of the number of nodes.)
- Tolerable communication bandwidth for cyclic communication (@1444 bytes): 3000 (pps) *4
- Tolerable communication bandwidth for cyclic communication (@504 bytes): 6000 (pps) *4
- Transmission trigger: Output to the adapter: Cyclic
- UCMM (non-connection type): Client: No. of simultaneous messages: 32
- VT3 connection: No. of sockets TCP: 0 UDP: 1 Port No.: 8502 (can be set within the range between 1 and 65535)
- Weight: Approx. 110 g
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number KV-NC1EP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- KV-NC1EP
- Brand
- KEYENCE
- Part Number
- KV-NC1EP
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- DNS
- No. of sockets UDP: 1 Port No.: 53
- Weight
- Approx. 110 g
- Packaging
- New surplus, factory sealed original packaging
- FTP client
- No. of sockets TCP: 2 Port No.: 20, 21 (can be set within the range between 1 and 65535)
- FTP server
- No. of sockets TCP: 4 Port No.: 20, 21
- Easy PLC link
- No. of sockets UDP: 1 Port No.: 5001 (can be set within the range between 1 and 65535)
- VT3 connection
- No. of sockets TCP: 0 UDP: 1 Port No.: 8502 (can be set within the range between 1 and 65535)
- Transmission trigger
- Output to the adapter: Cyclic
- Host link communication
- No. of sockets TCP: Total: 15 UDP: 1 Port No.: 8501 (can be set within the range between 1 and 65535) *9 *10
- MC protocol communication
- No. of sockets TCP: Total: 15 UDP: 1 Port No.: 5000 (can be set within the range between 1 and 65535) *11 *9 *10
- Multicast filter function
- Provided (IGMP client function) *6
- RP I (communication cycle)
- 0.5 to 10000 ms (0.5 ms increments) Setting is possible for each connection. (Data is updated on the line at specified cycles, independent of the number of nodes.)
- UCMM (non-connection type)
- Client: No. of simultaneous messages: 32
- Internal current consumption
- 90 mA or less
- Clock data automatic adjustment
- No. of sockets UDP: 1 Port No.: 123
- EtherNet/IP™ conformance test
- Conforming to CT10
- Maximum number of refresh words
- 8000 words
- Maximum data size per connection
- 504 bytes or 1444 bytes *5
- EtherNet/IP™ cyclic communication function
- No. of sockets TCP: Total: 320 UDP: 1 Port No.: 2222
- EtherNet/IP™ message communication function
- No. of sockets TCP: Total: 320 UDP: 1 Port No.: 44818
- Message communication / Class 3 (connection type)
- Server: No. of connections: 64 *7
- EtherNet/IP™ unit (communication specifications) / CIP service
- Cyclic communication Number of connections 64 *2
- EtherNet/IP™ unit (performance specifications) / PC applications
- No. of sockets TCP: 8 UDP: 0 Port No.: 8500 (can be set within the range between 1 and 65535) *8
- Tolerable communication bandwidth for cyclic communication (@504 bytes)
- 6000 (pps) *4
- Tolerable communication bandwidth for cyclic communication (@1444 bytes)
- 3000 (pps) *4
Compatibility Information
Match KV-NC1EP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing KV-NC1EP.
Maintenance Tips
Store KV-NC1EP dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. KV-NC1EP is in stock and ships within 1-2 business days, with a tracking number for every shipment.
KV-NC1EP is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match KV-NC1EP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114