+86 13348028050
IX-H2050 KEYENCE IX-H2050 - Front View | Vcocnc FANUC Parts

KEYENCE IX-H2050

Product information

$1,345.05 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: IX-H2050

Alternate: IXH2050

Brand
KEYENCE
Part No.
IX-H2050
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE IX-H2050 Product overview The KEYENCE IX-H2050 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analog voltage output: Not available - Conditions: 4 conditions Selectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG) - Detection history / Saved history: Scan mode 50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled) 80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled) 70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled) 100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled) *5 - Display / Min. display unit: Z axis 10 μm *1 - Display range / Z axis: ±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1 - Ethernet / Standard: Not available *6 - Function: IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error) - Image data transmission (FTP/SFTP client function) / Destination: FTP/SFTP server - Input / Input: Switchable between non-voltage input and voltage input For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) - Interface compatibility: CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *7 - Line mode: Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation, Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools *3 , Position adjustment: 1 tool, Tilt adjustment: 1 tool *2 - Main unit / expansion unit: Expansion unit - Method: Selectable between bmp, jpeg, and txt - NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less - Number of connectible units: Main units: 1, Expansion units: 1, Communication units (DL): 1 - Number of inputs: 8 (IN1 to IN8) - Number of programs: 32 - Other functions / Common: Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR), Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Mutual interference prevention, Security - Output / Output: Open collector output - Save conditions: Selectable between NG only and All *5 - Scan mode: Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function - Statistical information: Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1 *4 - Tools / Scan mode: Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation, Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool *2 - X axis: 50 μm *1 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number IX-H2050 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
IX-H2050
Brand
KEYENCE
Part Number
IX-H2050
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Method
Selectable between bmp, jpeg, and txt
X axis
50 μm *1
Function
IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions Assignable functions: Program switching, Laser emission stop, Zero/offset (batch), Reset (error only), Reset (judgment value only) Reset (judgment value and error)
Line mode
Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation, Position adjustment, Tilt adjustment (Max. number of settings) Judgment: 16 tools *3 , Position adjustment: 1 tool, Tilt adjustment: 1 tool *2
Packaging
New surplus, factory sealed original packaging
Scan mode
Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), Tilt correction (fixed or real-time correction), Glare removal, Trigger input (internal/external), Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Area height histogram, Fixed reference area, Mask outline, Rotation range, Height image display on tool setting screen, Scaling function
Conditions
4 conditions Selectable between All, Total judgment result (OK/NG), Result of each tool (OK/(NG and ALM)), and Result of the logical operation of each tool (OK/NG)
Input / Input
Switchable between non-voltage input and voltage input For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Output / Output
Open collector output
Save conditions
Selectable between NG only and All *5
Number of inputs
8 (IN1 to IN8)
Tools / Scan mode
Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation, Position adjustment, 1-axis adjustment, 2-axis adjustment (Max. number of settings) Judgment: 16 tools, Position adjustment: 1 tool *2
Number of programs
32
Ethernet / Standard
Not available *6
Analog voltage output
Not available
Display range / Z axis
±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1
Interface compatibility
CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *7
Statistical information
Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers) *1 *4
Other functions / Common
Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR), Sensor date/time information addition, N.O./N.C. switching, I/O monitor, Automatic brightness adjustment, Lighting (ON/OFF), Total judgment conditions, NPN/PNP switching, Simultaneous main unit/expansion unit input, Mutual interference prevention, Security
Main unit / expansion unit
Expansion unit
Display / Min. display unit
Z axis 10 μm *1
Number of connectible units
Main units: 1, Expansion units: 1, Communication units (DL): 1
Detection history / Saved history
Scan mode 50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled) 80 (FTP/SFTP client function: Enabled/High-resolution mode: Disabled) 70 (FTP/SFTP client function: Disabled/High-resolution mode: Enabled) 100 (FTP/SFTP client function: Disabled/High-resolution mode: Disabled) *5
Image data transmission (FTP/SFTP client function) / Destination
FTP/SFTP server
NPN/PNP switchable, N.O./N.C. switchable For open collector NPN output
Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 1.5 V or less For open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit), residual voltage of 2 V or less

Compatibility Information

Match IX-H2050 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing IX-H2050.

Maintenance Tips

Store IX-H2050 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114