Product Description

KEYENCE IV-G15 Product overview The KEYENCE IV-G15 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analysis information: OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *7 - Condition: NG only/All is selectable *6 - Connector: RJ-45 8pin connector *9 - Current consumption: 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.) - Environmental resistance / Ambient temperature: 0 to +50 °C 32 to 122 °F (No freezing) *10 - Ethernet / Standard: 100BASE-TX/10BASE-T *9 - Function: IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input - Image history / Numbers: When using a color type head: 100 images *4 , when using a monochrome type head: 300 images *5 *6 - Indicators: PWR/ERR, OUT, TRIG, STATUS, LINK/ACT - Input / Type: Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V) - Inputs: 6 inputs (IN1 to IN6) - Material: Main unit case: Polycarbonate - Network function: FTP client, EtherNet/IP™, PROFINET - Number: Detection tools: 16 tools, position adjustment tool: 1 tool *3 - Other functions: HDR, HighGain, Color filters *1 , Digital zoom (2x, 4x) *8 , Brightness correction, Tilt correction, White balance *1 , Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgment result output, Direct connection (2 units or more), Failing sensor list, Failure hold - Output / Type: Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower - Outputs: 8 outputs (OUT1 to OUT8) - Rating / Power voltage: Supplied from main unit - Relative humidity: 35 to 85 % RH (No condensation) - Switch settings (programs): 32 programs - Tools / Type: Shape Detection, Color Area *1 , Area *2 , position adjustment - Type: Expansion unit - Weight: Approx. 150 g Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number IV-G15 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
IV-G15
Brand
KEYENCE
Part Number
IV-G15
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Expansion unit
Inputs
6 inputs (IN1 to IN6)
Number
Detection tools: 16 tools, position adjustment tool: 1 tool *3
Weight
Approx. 150 g
Outputs
8 outputs (OUT1 to OUT8)
Function
IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input
Material
Main unit case: Polycarbonate
Connector
RJ-45 8pin connector *9
Packaging
New surplus, factory sealed original packaging
Indicators
PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
Input / Type
Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Tools / Type
Shape Detection, Color Area *1 , Area *2 , position adjustment
Output / Type
Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower
Other functions
HDR, HighGain, Color filters *1 , Digital zoom (2x, 4x) *8 , Brightness correction, Tilt correction, White balance *1 , Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgment result output, Direct connection (2 units or more), Failing sensor list, Failure hold
Network function
FTP client, EtherNet/IP™, PROFINET
Relative humidity
35 to 85 % RH (No condensation)
Current consumption
0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.)
Ethernet / Standard
100BASE-TX/10BASE-T *9
Analysis information
OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *7
Rating / Power voltage
Supplied from main unit
Image history / Numbers
When using a color type head: 100 images *4 , when using a monochrome type head: 300 images *5 *6
Switch settings (programs)
32 programs
Environmental resistance / Ambient temperature
0 to +50 °C 32 to 122 °F (No freezing) *10

Compatibility Information

Match IV-G15 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing IV-G15.

Maintenance Tips

Store IV-G15 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114