KEYENCE IV-G15
Product information
$547.02 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: IV-G15
Alternate: IVG15
Brand
KEYENCE
Part No.
IV-G15
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE IV-G15
Product overview
The KEYENCE IV-G15 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Analysis information: OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *7
- Condition: NG only/All is selectable *6
- Connector: RJ-45 8pin connector *9
- Current consumption: 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.)
- Environmental resistance / Ambient temperature: 0 to +50 °C 32 to 122 °F (No freezing) *10
- Ethernet / Standard: 100BASE-TX/10BASE-T *9
- Function: IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input
- Image history / Numbers: When using a color type head: 100 images *4 , when using a monochrome type head: 300 images *5 *6
- Indicators: PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
- Input / Type: Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
- Inputs: 6 inputs (IN1 to IN6)
- Material: Main unit case: Polycarbonate
- Network function: FTP client, EtherNet/IP™, PROFINET
- Number: Detection tools: 16 tools, position adjustment tool: 1 tool *3
- Other functions: HDR, HighGain, Color filters *1 , Digital zoom (2x, 4x) *8 , Brightness correction, Tilt correction, White balance *1 , Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgment result output, Direct connection (2 units or more), Failing sensor list, Failure hold
- Output / Type: Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower
- Outputs: 8 outputs (OUT1 to OUT8)
- Rating / Power voltage: Supplied from main unit
- Relative humidity: 35 to 85 % RH (No condensation)
- Switch settings (programs): 32 programs
- Tools / Type: Shape Detection, Color Area *1 , Area *2 , position adjustment
- Type: Expansion unit
- Weight: Approx. 150 g
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number IV-G15 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- IV-G15
- Brand
- KEYENCE
- Part Number
- IV-G15
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Expansion unit
- Inputs
- 6 inputs (IN1 to IN6)
- Number
- Detection tools: 16 tools, position adjustment tool: 1 tool *3
- Weight
- Approx. 150 g
- Outputs
- 8 outputs (OUT1 to OUT8)
- Function
- IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input
- Material
- Main unit case: Polycarbonate
- Connector
- RJ-45 8pin connector *9
- Packaging
- New surplus, factory sealed original packaging
- Indicators
- PWR/ERR, OUT, TRIG, STATUS, LINK/ACT
- Input / Type
- Non-voltage input/voltage input is switchable For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit) For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
- Tools / Type
- Shape Detection, Color Area *1 , Area *2 , position adjustment
- Output / Type
- Open collector output NPN/PNP is switchable, N.O./N.C. is switchable For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower
- Other functions
- HDR, HighGain, Color filters *1 , Digital zoom (2x, 4x) *8 , Brightness correction, Tilt correction, White balance *1 , Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Total judgment result output, Direct connection (2 units or more), Failing sensor list, Failure hold
- Network function
- FTP client, EtherNet/IP™, PROFINET
- Relative humidity
- 35 to 85 % RH (No condensation)
- Current consumption
- 0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.)
- Ethernet / Standard
- 100BASE-TX/10BASE-T *9
- Analysis information
- OFF/Statistics/Histograms is switchable Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgment results list by tools Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs *7
- Rating / Power voltage
- Supplied from main unit
- Image history / Numbers
- When using a color type head: 100 images *4 , when using a monochrome type head: 300 images *5 *6
- Switch settings (programs)
- 32 programs
- Environmental resistance / Ambient temperature
- 0 to +50 °C 32 to 122 °F (No freezing) *10
Compatibility Information
Match IV-G15 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing IV-G15.
Maintenance Tips
Store IV-G15 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. IV-G15 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
IV-G15 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match IV-G15 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114