Product Description

Schneider Electric GV4PE02S6 Product overview The Schneider Electric GV4PE02S6 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Breaking capacity: 120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947 - Characteristic: Value(s) - Connection pitch: 1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders - Connections - terminals: Lugs-ring terminals - Control Type: Toggle - Depth: 4.6 in (116 mm) - Device Application: Motor protection - Device short name: GV4PE - Electrical durability: 40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In - Height: 6.1 in (155 mm) - Line Rated Current: 2 A - Magnetic tripping current: 34 A - Maximum operating rate: 25 cyc/h - Mechanical durability: 40000 cycles - Mechanical robustness: Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27 - Motor power kW: 0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz - Operating position: Any position - Phase failure sensitivity: Yes IEC 60947-4-1 - Poles description: 3P - Power dissipation per pole: 4.6 W - Product Weight: 3.20 lb(US) (1.45 kg) - Product or Component Type: Motor circuit breaker - Range: TeSys Deca - Range of Product: TeSys GV4 - Rated duty: Continuous IEC 60947-4-1 - Suitability for isolation: Yes IEC 60947-1 - Tightening torque: 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²) 44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²) - Trip unit technology: Thermal-magnetic Electronic - Utilisation category: Category A IEC 60947-2 AC-3 IEC 60947-4-1 - Width: 3.2 in (81 mm) - [Ith] conventional free air thermal current: 115 A IEC 60947-4-1 - [Ue] rated operational voltage: 690 V AC 50/60 Hz IEC 60947-2 - [Ui] rated insulation voltage: 800 V AC 50/60 Hz IEC 60947-2 - [Uimp] rated impulse withstand voltage: 8 kV IEC 60947-2 - color: Gray RAL 7016) - product name: TeSys GV4 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number GV4PE02S6 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
GV4PE02S6
Brand
Schneider Electric
Part Number
GV4PE02S6
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
4.6 in (116 mm)
Range
TeSys Deca
Width
3.2 in (81 mm)
color
Gray RAL 7016)
Height
6.1 in (155 mm)
Rated duty
Continuous IEC 60947-4-1
Control Type
Toggle
product name
TeSys GV4
Characteristic
Value(s)
Motor power kW
0.25 kW 400...415 V AC 50/60 Hz 0.37 kW 400...415 V AC 50/60 Hz 0.55 kW 400...415 V AC 50/60 Hz 0.75 kW 400...415 V AC 50/60 Hz 0.37 kW 500 V AC 50/60 Hz 0.55 kW 500 V AC 50/60 Hz 0.75 kW 500 V AC 50/60 Hz 1.1 kW 500 V AC 50/60 Hz 0.55 kW 660...690 V AC 50/60 Hz 0.75 kW 660...690 V AC 50/60 Hz 1.1 kW 660...690 V AC 50/60 Hz 1.5 kW 660...690 V AC 50/60 Hz
Product Weight
3.20 lb(US) (1.45 kg)
Connection pitch
1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Range of Product
TeSys GV4
Breaking capacity
120 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 100 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 70 kA Icu 440 V AC 50/60 Hz IEC 60947-2 30 kA Icu 500 V AC 50/60 Hz IEC 60947-2 18 kA Icu 525 V AC 50/60 Hz IEC 60947-2 100 kA 208Y/120 V AC 50/60 Hz UL 60947 100 kA 240 V AC 50/60 Hz UL 60947 65 kA 480Y/277 V AC 50/60 Hz UL 60947 10 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 25 kA 600Y/347 V AC 50/60 Hz UL 60947
Device short name
GV4PE
Poles description
3P
Tightening torque
79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²) 44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Device Application
Motor protection
Line Rated Current
2 A
Operating position
Any position
Trip unit technology
Thermal-magnetic Electronic
Utilisation category
Category A IEC 60947-2 AC-3 IEC 60947-4-1
Electrical durability
40000 cycles AC-3 440 V In/2 40000 cycles AC-3 440 V In
Mechanical durability
40000 cycles
Mechanical robustness
Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 Shocks 15 gn 11 ms IEC 60068-2-27
Maximum operating rate
25 cyc/h
Connections - terminals
Lugs-ring terminals
Magnetic tripping current
34 A
Phase failure sensitivity
Yes IEC 60947-4-1
Product or Component Type
Motor circuit breaker
Suitability for isolation
Yes IEC 60947-1
Power dissipation per pole
4.6 W
[Ui] rated insulation voltage
800 V AC 50/60 Hz IEC 60947-2
[Ue] rated operational voltage
690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage
8 kV IEC 60947-2
[Ith] conventional free air thermal current
115 A IEC 60947-4-1

Compatibility Information

Match GV4PE02S6 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing GV4PE02S6.

Maintenance Tips

Store GV4PE02S6 dry and dust-free in its packaging until installation.