Schneider Electric GV3ME10 Product overview The Schneider Electric GV3ME10 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Breaking capacity: 100 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 2 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 - Characteristic: Value(s) - Connections - terminals: Power circuit: screw clamp terminal 1 cable(s) 2.5…35 mm²solid Power circuit: screw clamp terminal 1 cable(s) 2.5 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 16 mm²flexible with cable end - Depth: 113 mm - Device application: Motor - Device short name: thermal magnetic circuit breaker - Electrical durability: 30000 cycles for AC-3 at 440 V In/2 - Height: 120 mm - Maximum number of switchings: 25 cyc/h - Mechanical durability: 30000 cycles - Motor power kW: 2.2 kW at 400...415 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz - Mounting mode: Fixed - Mounting position: Vertical Horizontal - Mounting support: Plate Rail - Network frequency: 50/60 Hz - Network type: AC - Phase failure sensitivity: Yes conforming to IEC 60947-4-1 § 7-2-1-5-2 - Poles description: 3P - Power dissipation per pole: 8 W - Product or component type: Circuit breaker - Product weight: 0.6 kg - Range: TeSys - Rated duty: Continuous conforming to IEC 60947-4-1 - Thermal protection adjustment range: 4…6 A conforming to IEC 60947-4-1 - Tightening torque: 5 N.m - on EverLink BTR screw connectors - cable 2.5…16 mm² 5 N.m - on EverLink BTR screw connectors - cable 2.5…3.5 mm² - Trip unit technology: Thermal-magnetic - Utilisation category: Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 - Width: 61 mm - [Ics] rated service short-circuit breaking capacity: 100 % at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 - [Ith] conventional free air thermal current: 10 A conforming to IEC 60947-4-1 - [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to CSA C22.2 No 14 - [Ui] rated insulation voltage: 690 V conforming to IEC 60947-2 - [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2 - control type: Push-button - product name: TeSys GV3 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number GV3ME10 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
GV3ME10
Brand
Schneider Electric
Part Number
GV3ME10
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
113 mm
Range
TeSys
Width
61 mm
Height
120 mm
Packaging
New surplus, factory sealed original packaging
Rated duty
Continuous conforming to IEC 60947-4-1
Network type
AC
control type
Push-button
product name
TeSys GV3
Mounting mode
Fixed
Characteristic
Value(s)
Motor power kW
2.2 kW at 400...415 V AC 50/60 Hz 3 kW at 500 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz
Product weight
0.6 kg
Mounting support
Plate Rail
Breaking capacity
100 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 2 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Device short name
thermal magnetic circuit breaker
Mounting position
Vertical Horizontal
Network frequency
50/60 Hz
Poles description
3P
Tightening torque
5 N.m - on EverLink BTR screw connectors - cable 2.5…16 mm² 5 N.m - on EverLink BTR screw connectors - cable 2.5…3.5 mm²
Device application
Motor
Trip unit technology
Thermal-magnetic
Utilisation category
Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
Electrical durability
30000 cycles for AC-3 at 440 V In/2
Mechanical durability
30000 cycles
Connections - terminals
Power circuit: screw clamp terminal 1 cable(s) 2.5…35 mm²solid Power circuit: screw clamp terminal 1 cable(s) 2.5 mm²flexible without cable end Power circuit: screw clamp terminal 2 cable(s) 16 mm²flexible with cable end
Phase failure sensitivity
Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
Product or component type
Circuit breaker
Power dissipation per pole
8 W
Maximum number of switchings
25 cyc/h
[Ui] rated insulation voltage
690 V conforming to IEC 60947-2
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2 600 V AC 50/60 Hz conforming to UL 508 600 V AC 50/60 Hz conforming to CSA C22.2 No 14
Thermal protection adjustment range
4…6 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Ith] conventional free air thermal current
10 A conforming to IEC 60947-4-1
[Ics] rated service short-circuit breaking capacity
100 % at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2

Compatibility Information

Match GV3ME10 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing GV3ME10.

Maintenance Tips

Store GV3ME10 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options