+86 13348028050
GV3L251 Schneider Electric GV3L251 - Front View | Vcocnc FANUC Parts

Schneider Electric GV3L251

Product information

SKU: GV3L251

Alternate: GV3L251

Brand
Schneider Electric
Part No.
GV3L251
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

Schneider Electric GV3L251 Product overview The Schneider Electric GV3L251 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz 100 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz - Characteristic: Value(s) - Colour: Dark grey - Depth: 136 mm - Device application: Motor protection - Device short name: GV3L - Electrical durability: 50000 cycles for AC-3 at 415 V In - Fixing mode: 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) - Height: 114 mm - Magnetic tripping current: 350 A - Mechanical durability: 50000 cycles - Motor power kW: 11 kW at 400/415 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz - Mounting position: Horizontal Vertical - Network frequency: 50/60 Hz conforming to IEC 60947-2 - Network type: AC - Poles description: 3P - Power dissipation per pole: 8 W - Product or component type: Motor circuit breaker - Product weight: 0.96 kg - Range: TeSys Deca - Suitability for isolation: Yes conforming to IEC 60947-1 - Tightening torque: 5 N.m - on screw clamp terminal - Trip unit technology: Magnetic - Utilisation category: Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 - Width: 55 mm - [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz - [In] rated current: 25 A - [Ith] conventional free air thermal current: 25 A conforming to IEC 60947-2 - [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2 - [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2 - [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2 - control type: Rotary handle - product name: TeSys GV3 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number GV3L251 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
GV3L251
Brand
Schneider Electric
Part Number
GV3L251
Category
Schneider Electric Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Depth
136 mm
Range
TeSys Deca
Width
55 mm
Colour
Dark grey
Height
114 mm
Fixing mode
35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws)
Network type
AC
control type
Rotary handle
product name
TeSys GV3
Characteristic
Value(s)
Motor power kW
11 kW at 400/415 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 18.5 kW at 690 V AC 50/60 Hz
Product weight
0.96 kg
Breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz 100 kA Icu at 400/415 V AC 50/60 Hz 50 kA Icu at 440 V AC 50/60 Hz 12 kA Icu at 500 V AC 50/60 Hz 6 kA Icu at 690 V AC 50/60 Hz
Device short name
GV3L
Mounting position
Horizontal Vertical
Network frequency
50/60 Hz conforming to IEC 60947-2
Poles description
3P
Tightening torque
5 N.m - on screw clamp terminal
Device application
Motor protection
[In] rated current
25 A
Trip unit technology
Magnetic
Utilisation category
Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
Electrical durability
50000 cycles for AC-3 at 415 V In
Mechanical durability
50000 cycles
Magnetic tripping current
350 A
Product or component type
Motor circuit breaker
Suitability for isolation
Yes conforming to IEC 60947-1
Power dissipation per pole
8 W
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Ith] conventional free air thermal current
25 A conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz 100 % at 400/415 V AC 50/60 Hz 100 % at 440 V AC 50/60 Hz 50 % at 500 V AC 50/60 Hz 50 % at 690 V AC 50/60 Hz

Compatibility Information

Match GV3L251 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the Schneider Electric documentation for the host system when replacing GV3L251.

Maintenance Tips

Store GV3L251 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options