Schneider Electric GV2RT203
Product information
SKU: GV2RT203
Alternate: GV2RT203
Brand
Schneider Electric
Part No.
GV2RT203
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
Schneider Electric GV2RT203
Product overview
The Schneider Electric GV2RT203 is an automation spare part for Schneider Electric industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Breaking capacity: 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Characteristic: Value(s)
- Connections - terminals: Power circuit: spring terminals 2 cable(s) 1â¦6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5â¦4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1â¦4 mm²flexible with cable end
- Depth: 78.5 mm
- Device application: Motor protection Transformer
- Device short name: GV2RT
- Electrical durability: 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
- Fixing mode: 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
- Height: 89 mm
- Magnetic tripping current: 400 A
- Mechanical durability: 100000 cycles
- Motor power kW: 4 kW at 220/230 V AC 50/60 Hz motor protection high peak current 7.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current 7.5 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 500 V AC 50/60 Hz motor protection high peak current 15 kW at 690 V AC 50/60 Hz motor protection high peak current 5 kW at 230/240 V AC 50/60 Hz transformer protection 6.3 kW at 230/240 V AC 50/60 Hz transformer protection 10 kW at 400/415 V AC 50/60 Hz transformer protection 10 kW at 440 V AC 50/60 Hz transformer protection 10 kW at 500 V AC 50/60 Hz transformer protection 12.5 kW at 500 V AC 50/60 Hz transformer protection 10 kW at 690 V AC 50/60 Hz transformer protection
- Mounting position: Horizontal Vertical
- Network frequency: 50/60 Hz conforming to IEC 60947-2
- Network type: AC
- Poles description: 3P
- Power dissipation per pole: 2.5 W
- Product or component type: Motor circuit breaker
- Range: TeSys Deca
- Rated duty: Uninterrupted conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Thermal protection adjustment range: 13â¦18 A conforming to IEC 60947-2
- Trip unit technology: Thermal-magnetic
- Utilisation category: Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
- Width: 45 mm
- [In] rated current: 18 A
- [Ith] conventional free air thermal current: 18 A conforming to IEC 60947-2
- [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- control type: Toggle
- product name: TeSys GV2
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number GV2RT203 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- GV2RT203
- Brand
- Schneider Electric
- Part Number
- GV2RT203
- Category
- Schneider Electric Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Depth
- 78.5 mm
- Range
- TeSys Deca
- Width
- 45 mm
- Height
- 89 mm
- Rated duty
- Uninterrupted conforming to IEC 60947-4-1
- Fixing mode
- 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
- Network type
- AC
- control type
- Toggle
- product name
- TeSys GV2
- Characteristic
- Value(s)
- Motor power kW
- 4 kW at 220/230 V AC 50/60 Hz motor protection high peak current 7.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current 7.5 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 500 V AC 50/60 Hz motor protection high peak current 15 kW at 690 V AC 50/60 Hz motor protection high peak current 5 kW at 230/240 V AC 50/60 Hz transformer protection 6.3 kW at 230/240 V AC 50/60 Hz transformer protection 10 kW at 400/415 V AC 50/60 Hz transformer protection 10 kW at 440 V AC 50/60 Hz transformer protection 10 kW at 500 V AC 50/60 Hz transformer protection 12.5 kW at 500 V AC 50/60 Hz transformer protection 10 kW at 690 V AC 50/60 Hz transformer protection
- Breaking capacity
- 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Device short name
- GV2RT
- Mounting position
- Horizontal Vertical
- Network frequency
- 50/60 Hz conforming to IEC 60947-2
- Poles description
- 3P
- Device application
- Motor protection Transformer
- [In] rated current
- 18 A
- Trip unit technology
- Thermal-magnetic
- Utilisation category
- Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
- Electrical durability
- 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
- Mechanical durability
- 100000 cycles
- Connections - terminals
- Power circuit: spring terminals 2 cable(s) 1â¦6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5â¦4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1â¦4 mm²flexible with cable end
- Magnetic tripping current
- 400 A
- Product or component type
- Motor circuit breaker
- Suitability for isolation
- Yes conforming to IEC 60947-1
- Power dissipation per pole
- 2.5 W
- [Ui] rated insulation voltage
- 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Ue] rated operational voltage
- 690 V AC 50/60 Hz conforming to IEC 60947-2
- Thermal protection adjustment range
- 13â¦18 A conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage
- 6 kV conforming to IEC 60947-2
- [Ith] conventional free air thermal current
- 18 A conforming to IEC 60947-2
Compatibility Information
Match GV2RT203 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the Schneider Electric documentation for the host system when replacing GV2RT203.
Maintenance Tips
Store GV2RT203 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. GV2RT203 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
GV2RT203 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match GV2RT203 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
Schneider Electric ZR2FA2
SKU: ZR2FA2
Schneider Electric ZMLPA2P0SH
SKU: ZMLPA2P0SH
Schneider Electric ZMLPA2N0SH
SKU: ZMLPA2N0SH
Schneider Electric ZMLPA1P2SW