KEYENCE GC-1000R
Product information
$1,170.25 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: GC-1000R
Alternate: GC1000R
Brand
KEYENCE
Part No.
GC-1000R
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE GC-1000R
Product overview
The KEYENCE GC-1000R is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- AUX output specifications / Output type: Transistor output (PNP/NPN selectable by wiring) PNP output (DC-13, Type 0.1, Protected outputs) *1 *4
- AUX outputs: 4
- Applicable standards / EMC: EMS: IEC 61131-2/-6, EN61131-2/-6 EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A
- B10d: With rated load: 400,000 times With low load: 2,000,000 times
- Communication interface / USB: USB2.0
- Dimensions: 85×95×90 mm 3.35"×3.74"×3.54" (W×D×H)
- Display buttons: 4 points (3 operation keys + 1 BACK key)
- Environmental resistance / Ambient temperature: −10 to +55 °C 14 to 131 °F (No freezing)
- Ethernet: -
- GC-Link ports: 2 ports
- Input type: Type3
- Input/output points / Safety inputs: 14
- Leakage current (during OFF): Max. 0.5mA
- Load wiring resistance: Max. 2.5Ω
- Maximum cable length: Max. 100 m 328.1'
- Maximum capacitive load: 0.5 µF
- Maximum load current: 500 mA
- Maximum number of connectable expansion units: -
- OFF level (voltage/current): Max. 5 V/1.5 mA
- ON level (voltage/current): Min. 11 V/2 mA
- Operating altitude: Max. 2000 m 6561.7'
- Others / LCD display: 1.77-inch color LCD
- Overvoltage category: II III (relay output part of GC-1000R and GC-S1R)
- Power consumption: Max. 200 mA
- Power supply / Power voltage: 24 VDC (-20 to +20%) Class 2
- Protection circuit: Surge protection circuit, wrong wiring protection circuit
- Rated load (inductive load): 240 VAC 2A (AC-15) / 24 VDC 1A (DC-13)
- Rated load (resistance load): 250 VAC 6A / 30 VDC 6A *3
- Relative humidity: 5 to 85% (No condensation)
- Relay output mechanical life: Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times Resistance load (250 VAC 1A/30 VDC 1 A): Min. 500,000 times Inductive load (AC-15: 240 VAC 2 A): Min. 100,000 times (cosø = 0.3) Inductive load (DC-13: 24 VDC 1 A): Min. 100,000 times (L/R = 48 ms)
- Residual voltage (during ON): Max. 2.0 V
- Safety: IEC 61508, EN 61508 SIL3 IEC62061 SIL CL3 ISO/EN13849-1:2015 Cat. 4, PL e, UL1998
- Safety input specifications / Input device: Contact output device or PNP output device
- Safety output specifications / Output type: PNP transistor output (DC-13, Type 0.5, Protected outputs) *1
- Safety outputs: 4
- Safety relay output: 1 (3a)
- Safety relay output specifications / Output type: Relay (3a) (Externally-protected outputs) *2
- Short-circuit current: Si 0 to 3: Approx. 5 mA Si 4 to 13: Approx. 3 mA
- Storage temperature: −25 to +70 °C -13 to 158 °F (No freezing)
- Test output specifications / Output type: PNP transistor output *4
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number GC-1000R with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- GC-1000R
- Brand
- KEYENCE
- Part Number
- GC-1000R
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- B10d
- With rated load: 400,000 times With low load: 2,000,000 times
- Safety
- IEC 61508, EN 61508 SIL3 IEC62061 SIL CL3 ISO/EN13849-1:2015 Cat. 4, PL e, UL1998
- Ethernet
- -
- Packaging
- New surplus, factory sealed original packaging
- Dimensions
- 85×95×90 mm 3.35"×3.74"×3.54" (W×D×H)
- Input type
- Type3
- AUX outputs
- 4
- GC-Link ports
- 2 ports
- Safety outputs
- 4
- Display buttons
- 4 points (3 operation keys + 1 BACK key)
- Power consumption
- Max. 200 mA
- Relative humidity
- 5 to 85% (No condensation)
- Operating altitude
- Max. 2000 m 6561.7'
- Protection circuit
- Surge protection circuit, wrong wiring protection circuit
- Safety relay output
- 1 (3a)
- Storage temperature
- −25 to +70 °C -13 to 158 °F (No freezing)
- Maximum cable length
- Max. 100 m 328.1'
- Maximum load current
- 500 mA
- Others / LCD display
- 1.77-inch color LCD
- Overvoltage category
- II III (relay output part of GC-1000R and GC-S1R)
- Short-circuit current
- Si 0 to 3: Approx. 5 mA Si 4 to 13: Approx. 3 mA
- Load wiring resistance
- Max. 2.5Ω
- Maximum capacitive load
- 0.5 µF
- Applicable standards / EMC
- EMS: IEC 61131-2/-6, EN61131-2/-6 EMI: IEC 61131-2, FCC Part15B Class A, ICES-003, Class A
- ON level (voltage/current)
- Min. 11 V/2 mA
- OFF level (voltage/current)
- Max. 5 V/1.5 mA
- Rated load (inductive load)
- 240 VAC 2A (AC-15) / 24 VDC 1A (DC-13)
- Leakage current (during OFF)
- Max. 0.5mA
- Power supply / Power voltage
- 24 VDC (-20 to +20%) Class 2
- Rated load (resistance load)
- 250 VAC 6A / 30 VDC 6A *3
- Relay output mechanical life
- Resistance load (250 VAC 6A/30 VDC 6A): Min. 100,000 times Resistance load (250 VAC 1A/30 VDC 1 A): Min. 500,000 times Inductive load (AC-15: 240 VAC 2 A): Min. 100,000 times (cosø = 0.3) Inductive load (DC-13: 24 VDC 1 A): Min. 100,000 times (L/R = 48 ms)
- Residual voltage (during ON)
- Max. 2.0 V
- Communication interface / USB
- USB2.0
- Input/output points / Safety inputs
- 14
- AUX output specifications / Output type
- Transistor output (PNP/NPN selectable by wiring) PNP output (DC-13, Type 0.1, Protected outputs) *1 *4
- Test output specifications / Output type
- PNP transistor output *4
- Safety input specifications / Input device
- Contact output device or PNP output device
- Safety output specifications / Output type
- PNP transistor output (DC-13, Type 0.5, Protected outputs) *1
- Maximum number of connectable expansion units
- -
- Environmental resistance / Ambient temperature
- −10 to +55 °C 14 to 131 °F (No freezing)
- Safety relay output specifications / Output type
- Relay (3a) (Externally-protected outputs) *2
Compatibility Information
Match GC-1000R against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing GC-1000R.
Maintenance Tips
Store GC-1000R dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. GC-1000R is in stock and ships within 1-2 business days, with a tracking number for every shipment.
GC-1000R is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match GC-1000R against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114