KEYENCE FR-SA1 Product overview The KEYENCE FR-SA1 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Analog output: 0–20 mA/4-20 mA Maximum load resistance 260 Ω (Response time: 0.2 s (90% response) after control output is confirmed) - Analog output accuracy / Resolution: 1 mm 0.04" *1 - Control output/auxiliary output: NPN/PNP open collector (switchable) up to 30 VDC or less, max 50 mA for each Total 750 mA or less for the entire amplifier when adding five or more expansion units Residual voltage 1.4 V or less (50 mA or less) N.O./N.C. switchable IO5 is switchable to external input - Environmental resistance / Ambient temperature: –20°C to +55°C -4°F to +131°F (no freezing) *5 - Expansion: Connected to FR-SA1 (with FR-S01 connected): up to 8 units (9 units total including main unit) *2 Connected to FR-SA1 (with FR-SH01(C) connected): up to 12 units (13 units total including main unit) *2 - External communication: — - External input: Short circuit current: 1.5 mA or less Input time: 500 ms or more - Full-scale accuracy: ±0.2 mA (full-scale = 20 mA) *1 - Material: PC - Output / No. of control outputs: Maximum 5 - Power consumption: When FR-S01 is connected: up to 1940 mW or less (72 mA or less at 24 V) When FR-SH01(C) is connected: up to 1560 mW or less (56 mA or less at 24 V) (Excluding Load Current) - Power supply / Power voltage: 24 VDC +25%/−20% *3 *4 including ripple, Class2 or LPS - Protection circuit: Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges - Relative humidity: Up to 85% RH (no condensation) - Response time: 0.4 s, 1.5 s, 4 s (default value), 10 s - Type: Short Separated Amplifier Unit Cable Main Unit - Weight: Approx. 100 g 3.53 oz - Zero accuracy: ±0.1 mA (zero point = 4 mA) *1 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FR-SA1 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FR-SA1
Brand
KEYENCE
Part Number
FR-SA1
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
Short Separated Amplifier Unit Cable Main Unit
Weight
Approx. 100 g 3.53 oz
Material
PC
Expansion
Connected to FR-SA1 (with FR-S01 connected): up to 8 units (9 units total including main unit) *2 Connected to FR-SA1 (with FR-SH01(C) connected): up to 12 units (13 units total including main unit) *2
Packaging
New surplus, factory sealed original packaging
Analog output
0–20 mA/4-20 mA Maximum load resistance 260 Ω (Response time: 0.2 s (90% response) after control output is confirmed)
Response time
0.4 s, 1.5 s, 4 s (default value), 10 s
Zero accuracy
±0.1 mA (zero point = 4 mA) *1
External input
Short circuit current: 1.5 mA or less Input time: 500 ms or more
Power consumption
When FR-S01 is connected: up to 1940 mW or less (72 mA or less at 24 V) When FR-SH01(C) is connected: up to 1560 mW or less (56 mA or less at 24 V) (Excluding Load Current)
Relative humidity
Up to 85% RH (no condensation)
Protection circuit
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges
Full-scale accuracy
±0.2 mA (full-scale = 20 mA) *1
External communication
—
Power supply / Power voltage
24 VDC +25%/−20% *3 *4 including ripple, Class2 or LPS
Control output/auxiliary output
NPN/PNP open collector (switchable) up to 30 VDC or less, max 50 mA for each Total 750 mA or less for the entire amplifier when adding five or more expansion units Residual voltage 1.4 V or less (50 mA or less) N.O./N.C. switchable IO5 is switchable to external input
Output / No. of control outputs
Maximum 5
Analog output accuracy / Resolution
1 mm 0.04" *1
Environmental resistance / Ambient temperature
–20°C to +55°C -4°F to +131°F (no freezing) *5

Compatibility Information

Match FR-SA1 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FR-SA1.

Maintenance Tips

Store FR-SA1 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114