Product Description

KEYENCE FR-LW20L Product overview The KEYENCE FR-LW20L is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 0.1 to 10 m 0.3' to 32.8': ±1 mm 0.04" - 10 to 20 m 32.8' to 65.6': ±2 mm 0.08" *3 - Analog output: 4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response]) - Analog output accuracy / Resolution: 1 mm 0.04" *4 - Connection diameter: G1-1/2 (40A) - Control output/auxiliary output: Transistor output (NPN open collector) Common independent type 35 VDC or less, 50 mA max. Residual voltage of 4.0 V or less (50 mA or less) N.O./N.C. switching - Display range: Up to 25 m 82.0' *1 - Enclosure rating: IP67 (IEC60529), Enclosure Type 4X (NEMA250) - Environmental resistance / Ambient temperature: -30 to +60°C -22 to 140°F (no freezing) - F.S. accuracy: ±0.2 mA (full scale = 20 mA) *4 - Fastener: SUS304 - Housing: PPS PC PA - Internal seal: FKM - Material / Tank interior: Lens: PTFE - Measurable dielectric constant of medium: 2 or more *2 - Measuring range: Up to 15 m 49.2' *1 - Network compatibility: HART - Output / No. of control outputs: 1 - Power consumption: 752.5 mW or less (including analog output - Power spectral density: 0.816 G 2 X, Y and Z directions - Power supply / Power voltage: 18.3 to 35 VDC. - Precision: Up to 0.1 m 0.3' : ±10 mm 0.39" - Protection circuit: Reverse power connection protection, power supply surge protection, output short-circuit protection, output surge protection - Relative humidity: Up to 85% RH (no condensation) - Resolution: 1 mm 0.04" - Response time: 1 s, 4 s (default value), 10 s, 25 s - Shock resistance: 100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions - Tank pressure: -0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F ) - Temperature of coupling used: -30 to +85°C -22 to 185°F (no freezing) - Type: 2-wire standard model - Vibration resistance: 10 to 500 Hz - Weight: Approx. 920 g 32.45 oz - Zero accuracy: ±0.1 mA (zero point = 4 mA) *4 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FR-LW20L with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FR-LW20L
Brand
KEYENCE
Part Number
FR-LW20L
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
2-wire standard model
Weight
Approx. 920 g 32.45 oz
Housing
PPS PC PA
Fastener
SUS304
Precision
Up to 0.1 m 0.3' : ±10 mm 0.39"
Resolution
1 mm 0.04"
Analog output
4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
Display range
Up to 25 m 82.0' *1
F.S. accuracy
±0.2 mA (full scale = 20 mA) *4
Internal seal
FKM
Response time
1 s, 4 s (default value), 10 s, 25 s
Tank pressure
-0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F )
Zero accuracy
±0.1 mA (zero point = 4 mA) *4
Measuring range
Up to 15 m 49.2' *1
Enclosure rating
IP67 (IEC60529), Enclosure Type 4X (NEMA250)
Shock resistance
100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
Power consumption
752.5 mW or less (including analog output
Relative humidity
Up to 85% RH (no condensation)
Protection circuit
Reverse power connection protection, power supply surge protection, output short-circuit protection, output surge protection
Connection diameter
G1-1/2 (40A)
Vibration resistance
10 to 500 Hz
Network compatibility
HART
Power spectral density
0.816 G 2 X, Y and Z directions
Material / Tank interior
Lens: PTFE
0.1 to 10 m 0.3' to 32.8'
±1 mm 0.04"
10 to 20 m 32.8' to 65.6'
±2 mm 0.08" *3
Power supply / Power voltage
18.3 to 35 VDC.
Temperature of coupling used
-30 to +85°C -22 to 185°F (no freezing)
Control output/auxiliary output
Transistor output (NPN open collector) Common independent type 35 VDC or less, 50 mA max. Residual voltage of 4.0 V or less (50 mA or less) N.O./N.C. switching
Output / No. of control outputs
1
Analog output accuracy / Resolution
1 mm 0.04" *4
Measurable dielectric constant of medium
2 or more *2
Environmental resistance / Ambient temperature
-30 to +60°C -22 to 140°F (no freezing)

Compatibility Information

Match FR-LW20L against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FR-LW20L.

Maintenance Tips

Store FR-LW20L dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114