+86 13348028050
FR-LEX20L KEYENCE FR-LEX20L - Front View | Vcocnc FANUC Parts

KEYENCE FR-LEX20L

Product information

SKU: FR-LEX20L

Alternate: FRLEX20L

Brand
KEYENCE
Part No.
FR-LEX20L
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE FR-LEX20L Product overview The KEYENCE FR-LEX20L is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - 0.1 to 10 m 0.3' to 32.8': ±1 mm 0.04" - 10 to 20 m 32.8' to 65.6': ±2 mm 0.08" *3 - ATEX and UKEX / Explosion-proof performance: II 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da (when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC (when using a Zener bar - Analog output: 4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response]) - Analog output accuracy / Resolution: 1 mm 0.04" *4 - Connection diameter: G1-1/2 (40A) - Display range: Up to 25 m 82.0' *1 - Electrical ratings: U i : 35 VDC / I i : 142.4 mA / P i : 1000 mW / L i : 26.2 nH / C i : 79 nF (when using an Isolated barrier) U m : 250 VRMS / U o : 26.78 VDC / I o : 115.307 mA / P o : 772 mW / L o (IIC): 0.2 mH / C o (IIC): 0.092 μF / L o (IIB): 0.2 mH / C o (IIB): 0.72 μF (when using a Zener barrier) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF (when using a Zener barrier with a flameproof enclosure) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF - Environmental resistance / Ambient temperature: -30 to +60°C -22 to 140°F (no freezing) (when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier with a flameproof enclosure) Barrier: -30 to +60°C -22 to 140°F (no freezing) - F.S. accuracy: ±0.2 mA (full scale = 20 mA) *4 - Fastener: SUS304 - Housing: PPS PC PA Internal potting agent: Epoxy resin (when using an Isolated barrier) Barrier: PC (when using a Zener barrier) Barrier: PC (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: Aluminium die casting, NBR Cable glands: Nickel-plated brass, chloroprene - IECEx / Explosion-proof performance: Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da (when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db - Internal seal: FFKM - Material / Tank interior: Lens: PTFE - Measurable dielectric constant of medium: 2 or more *2 - Measuring range: Up to 15 m 49.2' *1 - Network compatibility: HART - Output / No. of control outputs: ─ - Power consumption: 752.5 mW or less (including analog output - Power spectral density: 0.816 G 2 X, Y and Z directions - Power supply / Power voltage: 18.3 to 35 VDC. (when using an Isolated barrier) 24 VDC +25%/-10% (when using a Zener barrier) 20.1 to 28 VDC (when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC - Precision: Up to 0.1 m 0.3' : ±10 mm 0.39" - Relative humidity: Up to 85% RH (no condensation) - Resolution: 1 mm 0.04" - Response time: 1 s, 4 s (default value), 10 s, 25 s - Shock resistance: 100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions - Tank pressure: -0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F ) - Temperature: -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F (when using an Isolated barrier) ─ (when using a Zener barrier) ─ (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F - Temperature of coupling used: -30 to +85°C -22 to 185°F (no freezing) - Type: 2-wire explosion-proof model - Vibration resistance: 10 to 500 Hz - Zero accuracy: ±0.1 mA (zero point = 4 mA) *4 - Zone: Zone 0/20 (when using an Isolated barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier with a flameproof enclosure) Zone 1/21 Condition and supply - Price on request: send an inquiry with the quantity you need - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FR-LEX20L with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FR-LEX20L
Brand
KEYENCE
Part Number
FR-LEX20L
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Type
2-wire explosion-proof model
Zone
Zone 0/20 (when using an Isolated barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier with a flameproof enclosure) Zone 1/21
Housing
PPS PC PA Internal potting agent: Epoxy resin (when using an Isolated barrier) Barrier: PC (when using a Zener barrier) Barrier: PC (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: Aluminium die casting, NBR Cable glands: Nickel-plated brass, chloroprene
Fastener
SUS304
Precision
Up to 0.1 m 0.3' : ±10 mm 0.39"
Resolution
1 mm 0.04"
Temperature
-30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F (when using an Isolated barrier) ─ (when using a Zener barrier) ─ (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
Analog output
4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
Display range
Up to 25 m 82.0' *1
F.S. accuracy
±0.2 mA (full scale = 20 mA) *4
Internal seal
FFKM
Response time
1 s, 4 s (default value), 10 s, 25 s
Tank pressure
-0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F )
Zero accuracy
±0.1 mA (zero point = 4 mA) *4
Measuring range
Up to 15 m 49.2' *1
Shock resistance
100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
Power consumption
752.5 mW or less (including analog output
Relative humidity
Up to 85% RH (no condensation)
Electrical ratings
U i : 35 VDC / I i : 142.4 mA / P i : 1000 mW / L i : 26.2 nH / C i : 79 nF (when using an Isolated barrier) U m : 250 VRMS / U o : 26.78 VDC / I o : 115.307 mA / P o : 772 mW / L o (IIC): 0.2 mH / C o (IIC): 0.092 μF / L o (IIB): 0.2 mH / C o (IIB): 0.72 μF (when using a Zener barrier) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF (when using a Zener barrier with a flameproof enclosure) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF
Connection diameter
G1-1/2 (40A)
Vibration resistance
10 to 500 Hz
Network compatibility
HART
Power spectral density
0.816 G 2 X, Y and Z directions
Material / Tank interior
Lens: PTFE
0.1 to 10 m 0.3' to 32.8'
±1 mm 0.04"
10 to 20 m 32.8' to 65.6'
±2 mm 0.08" *3
Power supply / Power voltage
18.3 to 35 VDC. (when using an Isolated barrier) 24 VDC +25%/-10% (when using a Zener barrier) 20.1 to 28 VDC (when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC
Temperature of coupling used
-30 to +85°C -22 to 185°F (no freezing)
Output / No. of control outputs
─
Analog output accuracy / Resolution
1 mm 0.04" *4
IECEx / Explosion-proof performance
Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da (when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db
Measurable dielectric constant of medium
2 or more *2
ATEX and UKEX / Explosion-proof performance
II 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da (when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC (when using a Zener bar
Environmental resistance / Ambient temperature
-30 to +60°C -22 to 140°F (no freezing) (when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier with a flameproof enclosure) Barrier: -30 to +60°C -22 to 140°F (no freezing)

Compatibility Information

Match FR-LEX20L against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FR-LEX20L.

Maintenance Tips

Store FR-LEX20L dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114