KEYENCE FR-LEX20
Product information
SKU: FR-LEX20
Alternate: FRLEX20
Brand
KEYENCE
Part No.
FR-LEX20
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE FR-LEX20
Product overview
The KEYENCE FR-LEX20 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- 0.1 to 10 m 0.3' to 32.8': ±1 mm 0.04"
- 10 to 20 m 32.8' to 65.6': ±2 mm 0.08" *3
- ATEX and UKEX / Explosion-proof performance: II 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da (when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC (when using a Zener barr
- Analog output: 4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
- Analog output accuracy / Resolution: 1 mm 0.04" *4
- Connection diameter: G1-1/2 (40A)
- Display range: Up to 25 m 82.0' *1
- Electrical ratings: U i : 35 VDC / I i : 142.4 mA / P i : 1000 mW / L i : 26.2 nH / C i : 79 nF (when using an Isolated barrier) U m : 250 VRMS / U o : 26.78 VDC / I o : 115.307 mA / P o : 772 mW / L o (IIC): 0.2 mH / C o (IIC): 0.092 μF / L o (IIB): 0.2 mH / C o (IIB): 0.72 μF (when using a Zener barrier) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF (when using a Zener barrier with a flameproof enclosure) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF
- Environmental resistance / Ambient temperature: -30 to +60°C -22 to 140°F (no freezing) (when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier with a flameproof enclosure) Barrier: -30 to +60°C -22 to 140°F (no freezing)
- F.S. accuracy: ±0.2 mA (full scale = 20 mA) *4
- Fastener: SUS304
- Housing: PPS PC PA Internal potting agent: Epoxy resin (when using an Isolated barrier) Barrier: PC (when using a Zener barrier) Barrier: PC (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: Aluminium die casting, NBR Cable glands: Nickel-plated brass, chloroprene
- IECEx / Explosion-proof performance: Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da (when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db
- Internal seal: FFKM
- Material / Tank interior: Lens: PTFE
- Measurable dielectric constant of medium: 2 or more *2
- Measuring range: Up to 20 m 65.6' *1
- Network compatibility: HART
- Output / No. of control outputs: ─
- Power consumption: 752.5 mW or less (including analog output
- Power spectral density: 0.816 G 2 X, Y and Z directions
- Power supply / Power voltage: 18.3 to 35 VDC. (when using an Isolated barrier) 24 VDC +25%/-10% (when using a Zener barrier) 20.1 to 28 VDC (when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC
- Precision: Up to 0.1 m 0.3' : ±10 mm 0.39"
- Relative humidity: Up to 85% RH (no condensation)
- Resolution: 1 mm 0.04"
- Response time: 1 s, 4 s (default value), 10 s, 25 s
- Shock resistance: 100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
- Tank pressure: -0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F )
- Temperature: -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F (when using an Isolated barrier) ─ (when using a Zener barrier) ─ (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
- Temperature of coupling used: -30 to +85°C -22 to 185°F (no freezing)
- Type: 2-wire explosion-proof model
- Vibration resistance: 10 to 500 Hz
- Zero accuracy: ±0.1 mA (zero point = 4 mA) *4
- Zone: Zone 0/20 (when using an Isolated barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier with a flameproof enclosure) Zone 1/21
Condition and supply
- Price on request: send an inquiry with the quantity you need
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number FR-LEX20 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- FR-LEX20
- Brand
- KEYENCE
- Part Number
- FR-LEX20
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- 2-wire explosion-proof model
- Zone
- Zone 0/20 (when using an Isolated barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier) Do not install in a hazardous location (associated apparatus *5 ) (when using a Zener barrier with a flameproof enclosure) Zone 1/21
- Housing
- PPS PC PA Internal potting agent: Epoxy resin (when using an Isolated barrier) Barrier: PC (when using a Zener barrier) Barrier: PC (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: Aluminium die casting, NBR Cable glands: Nickel-plated brass, chloroprene
- Fastener
- SUS304
- Precision
- Up to 0.1 m 0.3' : ±10 mm 0.39"
- Resolution
- 1 mm 0.04"
- Temperature
- -30°C -22°F ≤ Ta ≤ 60°C 140°F / -30°C -22°F ≤ Tp ≤ 85°C 185°F (when using an Isolated barrier) ─ (when using a Zener barrier) ─ (when using a Zener barrier with a flameproof enclosure) Explosion-proof enclosure: -30°C -22°F ≤ Ta ≤ 60°C 140°F
- Analog output
- 4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
- Display range
- Up to 25 m 82.0' *1
- F.S. accuracy
- ±0.2 mA (full scale = 20 mA) *4
- Internal seal
- FFKM
- Response time
- 1 s, 4 s (default value), 10 s, 25 s
- Tank pressure
- -0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F )
- Zero accuracy
- ±0.1 mA (zero point = 4 mA) *4
- Measuring range
- Up to 20 m 65.6' *1
- Shock resistance
- 100 m/s 2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
- Power consumption
- 752.5 mW or less (including analog output
- Relative humidity
- Up to 85% RH (no condensation)
- Electrical ratings
- U i : 35 VDC / I i : 142.4 mA / P i : 1000 mW / L i : 26.2 nH / C i : 79 nF (when using an Isolated barrier) U m : 250 VRMS / U o : 26.78 VDC / I o : 115.307 mA / P o : 772 mW / L o (IIC): 0.2 mH / C o (IIC): 0.092 μF / L o (IIB): 0.2 mH / C o (IIB): 0.72 μF (when using a Zener barrier) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF (when using a Zener barrier with a flameproof enclosure) U m : 250 VRMS / U o : 34.33 VDC / I o : 112.007 mA / P o : 961.3 mW / L o : 1.0 mH / Co: 0.37 μF
- Connection diameter
- G1-1/2 (40A)
- Vibration resistance
- 10 to 500 Hz
- Network compatibility
- HART
- Power spectral density
- 0.816 G 2 X, Y and Z directions
- Material / Tank interior
- Lens: PTFE
- 0.1 to 10 m 0.3' to 32.8'
- ±1 mm 0.04"
- 10 to 20 m 32.8' to 65.6'
- ±2 mm 0.08" *3
- Power supply / Power voltage
- 18.3 to 35 VDC. (when using an Isolated barrier) 24 VDC +25%/-10% (when using a Zener barrier) 20.1 to 28 VDC (when using a Zener barrier with a flameproof enclosure) 20.1 to 28 VDC
- Temperature of coupling used
- -30 to +85°C -22 to 185°F (no freezing)
- Output / No. of control outputs
- ─
- Analog output accuracy / Resolution
- 1 mm 0.04" *4
- IECEx / Explosion-proof performance
- Ex ia IIC T4 Ga or Ex ia IIB T4 Ga Ex ia IIIC T135°C Da (when using an Isolated barrier) [Ex ia Ga] IIC or [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier) [Ex ia Ga] IIB [Ex ia Da] IIIC (when using a Zener barrier with a flameproof enclosure) Ex db [ia Ga] IIB T4 Gb Ex tb [ia Da] IIIC T135°C Db
- Measurable dielectric constant of medium
- 2 or more *2
- ATEX and UKEX / Explosion-proof performance
- II 1 G Ex ia IIC T4 Ga or II 1 G Ex ia IIB T4 Ga II 1 D Ex ia IIIC T135°C Da (when using an Isolated barrier) II (1) G [Ex ia Ga] IIC or II (1) G [Ex ia Ga] IIB II (1) D [Ex ia Da] IIIC (when using a Zener barr
- Environmental resistance / Ambient temperature
- -30 to +60°C -22 to 140°F (no freezing) (when using an Isolated barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier) Barrier: -30 to +60°C -22 to 140°F (no freezing) (when using a Zener barrier with a flameproof enclosure) Barrier: -30 to +60°C -22 to 140°F (no freezing)
Compatibility Information
Match FR-LEX20 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing FR-LEX20.
Maintenance Tips
Store FR-LEX20 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. FR-LEX20 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
FR-LEX20 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match FR-LEX20 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114