+86 13348028050
FL-S001 KEYENCE FL-S001 - Front View | Vcocnc FANUC Parts

KEYENCE FL-S001

Product information

$1,276.22 USD

Condition: new

Shipping calculated at checkout ( Shipping Policy · 30-Day Returns )

SKU: FL-S001

Alternate: FLS001

Brand
KEYENCE
Part No.
FL-S001
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
12 months Warranty
Worldwide Shipping
Quality Tested

Product Description

KEYENCE FL-S001 Product overview The KEYENCE FL-S001 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient temperature: -20 to +60 °C -4 to +140°F - Analog output: 4 to 20 mA, maximum load resistance: 350 Ω (Response time: 0.1 s after comparator output determined [90 % response]) Ripple when target remains stationary (P-P) 2 % of F.S. max. - Analog output accuracy / Resolution: 1 mm 0.04" - Applicable cable: 8-pin M12 connector - Bottom side: 45 mm 1.77" max. *3 - Case: Metal section of the housing: SUS304 Plastic section of the housing: PBT, PAR, HNBR, EPDM, PTFE, PPSU, PET - Connection port: 2S ferrule - Control output / Judgment output/alarm output: NPN/PNP open collector (selectable), 30 VDC max., 50 mA max. for each Residual voltage: 2 V max. for NPN, 2.5 V max. for PNP, N.O./N.C. switchable - Current consumption: 300 mA max. (at 10 V)/120 mA max. (at 30 V) (excluding load) - Environmental resistance / Enclosure rating: IP67 - Full scale accuracy: ±0.2 mA (full scale = 20 mA) - In the case of oil / Top side: 50 mm 1.97" - Judgment output response time: 0.4 s minimum - Linearity: ±3 mm ±0.12" *2 - Material / Liquid end materials: Sheath: PFA Probe: SUS304 (do not connect this directly) - Measurement range: 200 to 2,000 mm 7.87" to 78.74" - Network compatibility: IO-Link *4 - Operating medium temperature: -20 to +150 °C -4 to 302 °F - Probe horizontal torque: 6 N m - Rating / Power voltage: 10 to 30 VDC, ripple (P-P) 10% included, Class 2 or LPS - Relative humidity: 35 to 85 % RH (No condensation) - Resolution: 1 mm 0.04" *2 - Shock resistance: 300 m/s 2 in 6 directions, 3 times respectively - Specific conductive capacity of measurable media: 2 or more *1 - Tank pressure: -0.1 to +1 Mpa - Temperature characteristics: 0.1 mm/°C - Type: Sanitary type - Undetectable area / In the case of water: Top side 25 mm 0.98" - Vibration resistance: 10 to 55 Hz, 0.75 mm 0.03" double amplitude in X, Y and Z directions, 2 hours respectively - Weight: 670 g - Zero accuracy: ±0.1 mA (Zero point = 4 mA) Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FL-S001 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FL-S001
Brand
KEYENCE
Part Number
FL-S001
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Case
Metal section of the housing: SUS304 Plastic section of the housing: PBT, PAR, HNBR, EPDM, PTFE, PPSU, PET
Type
Sanitary type
Weight
670 g
Linearity
±3 mm ±0.12" *2
Packaging
New surplus, factory sealed original packaging
Resolution
1 mm 0.04" *2
Bottom side
45 mm 1.77" max. *3
Analog output
4 to 20 mA, maximum load resistance: 350 Ω (Response time: 0.1 s after comparator output determined [90 % response]) Ripple when target remains stationary (P-P) 2 % of F.S. max.
Tank pressure
-0.1 to +1 Mpa
Zero accuracy
±0.1 mA (Zero point = 4 mA)
Connection port
2S ferrule
Applicable cable
8-pin M12 connector
Shock resistance
300 m/s 2 in 6 directions, 3 times respectively
Measurement range
200 to 2,000 mm 7.87" to 78.74"
Relative humidity
35 to 85 % RH (No condensation)
Ambient temperature
-20 to +60 °C -4 to +140°F
Current consumption
300 mA max. (at 10 V)/120 mA max. (at 30 V) (excluding load)
Full scale accuracy
±0.2 mA (full scale = 20 mA)
Vibration resistance
10 to 55 Hz, 0.75 mm 0.03" double amplitude in X, Y and Z directions, 2 hours respectively
Network compatibility
IO-Link *4
Rating / Power voltage
10 to 30 VDC, ripple (P-P) 10% included, Class 2 or LPS
Probe horizontal torque
6 N m
Temperature characteristics
0.1 mm/°C
Operating medium temperature
-20 to +150 °C -4 to 302 °F
In the case of oil / Top side
50 mm 1.97"
Judgment output response time
0.4 s minimum
Material / Liquid end materials
Sheath: PFA Probe: SUS304 (do not connect this directly)
Analog output accuracy / Resolution
1 mm 0.04"
Undetectable area / In the case of water
Top side 25 mm 0.98"
Environmental resistance / Enclosure rating
IP67
Control output / Judgment output/alarm output
NPN/PNP open collector (selectable), 30 VDC max., 50 mA max. for each Residual voltage: 2 V max. for NPN, 2.5 V max. for PNP, N.O./N.C. switchable
Specific conductive capacity of measurable media
2 or more *1

Compatibility Information

Match FL-S001 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FL-S001.

Maintenance Tips

Store FL-S001 dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114