KEYENCE FD-R50
Product overview
The KEYENCE FD-R50 is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Ambient temperature: - 20 to + 60°C - 4.0 to 140 °F (no freezing) *2
- Analog output (ch.1/ch.2): Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less *7
- Current consumption: When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less
- Dimensions: Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"
- Display method: Dual row, 5-digit display with white, 14-segment LED
- Display resolution: 0.1 / 1 (L / min)
- Display update cycle: Approx. 3 Hz
- Environmental resistance / Enclosure rating: IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)
- External input (ch.2): Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more *7
- Flow units: L / min, m 3 / h, gal / min
- Hysteresis: Variable
- I/O: When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block
- Input/Output (Selectable) / Output (ch.1/ch.2): Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less *7
- Integrated flow unit display: 1 / 10 / 100 / 1000 / 10000 (L)
- Material / Main unit: Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent
- Maximum rated flow: Rated flow velocity range: 5.0 m/s Flow rate range (Typical): 1 1/2" (40 A): 400 L / min 100 gal / min 24 m 3 / h) 2" (50 A): 600 L / min 150 gal / min 36 m 3 / h
- Measurement accuracy: Between 20 and 100% of F.S. : ±2.0% of RD *4 *5 Between 6 and 20% of F.S. : ±0.4% of F.S. *4 *5
- Pipe temperature measurement accuracy: ±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F ) ±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F ) (ambient operating temperature of 25°C 77°F ) *4
- Protection circuit: Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output
- Rating / Power voltage: 20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)
- Relative humidity: 5 to 90%RH (no condensation)
- Response time: 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)
- Shock resistance: 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
- Supported fluid temperature: - 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface) *2
- Supported fluids: Various liquids (i.e. water, oils, chemicals) *1
- Supported pipe diameter: 1 1/2" (40 A), ø44 to ø55 1.73" to 2.17" 2" (50 A), ø55 to ø64 2.17" to 2.52"
- Supported pipe materials: Metal / resin *1
- Unit rear: Rubber
- Upper/lower bracket: SUS304
- Vibration resistance: 10 to 55 Hz, compound amplitude 1.5 mm 0.06" , XYZ axes 2 hours for each axis
- Weight: Main unit: Approx. 1.0 kg Upper/lower bracket: Approx.1.5 kg (including sub unit)
- Wiring specifications / Power supply: DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)
- Zero cut flow rate: Zero cut: 0.3 m/s (default) *3 Flow rate (Typical): 36 L / min 9 gal / min 2.4 m 3 / h
- Zero point error: ±0.5% of F.S. *4 *6
Condition and supply
- New surplus, factory sealed original packaging
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number FD-R50 with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- FD-R50
- Brand
- KEYENCE
- Part Number
- FD-R50
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- I/O
- When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block
- Weight
- Main unit: Approx. 1.0 kg Upper/lower bracket: Approx.1.5 kg (including sub unit)
- Packaging
- New surplus, factory sealed original packaging
- Unit rear
- Rubber
- Dimensions
- Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78"
- Flow units
- L / min, m 3 / h, gal / min
- Hysteresis
- Variable
- Response time
- 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable)
- Display method
- Dual row, 5-digit display with white, 14-segment LED
- Shock resistance
- 100 m/s 2 , 16 ms pulse, XYZ axes, 1000 times for each axis
- Supported fluids
- Various liquids (i.e. water, oils, chemicals) *1
- Zero point error
- ±0.5% of F.S. *4 *6
- Relative humidity
- 5 to 90%RH (no condensation)
- Display resolution
- 0.1 / 1 (L / min)
- Maximum rated flow
- Rated flow velocity range: 5.0 m/s Flow rate range (Typical): 1 1/2" (40 A): 400 L / min 100 gal / min 24 m 3 / h) 2" (50 A): 600 L / min 150 gal / min 36 m 3 / h
- Protection circuit
- Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output
- Zero cut flow rate
- Zero cut: 0.3 m/s (default) *3 Flow rate (Typical): 36 L / min 9 gal / min 2.4 m 3 / h
- Ambient temperature
- - 20 to + 60°C - 4.0 to 140 °F (no freezing) *2
- Current consumption
- When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less
- Upper/lower bracket
- SUS304
- Display update cycle
- Approx. 3 Hz
- Material / Main unit
- Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent
- Measurement accuracy
- Between 20 and 100% of F.S. : ±2.0% of RD *4 *5 Between 6 and 20% of F.S. : ±0.4% of F.S. *4 *5
- Vibration resistance
- 10 to 55 Hz, compound amplitude 1.5 mm 0.06" , XYZ axes 2 hours for each axis
- External input (ch.2)
- Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more *7
- Rating / Power voltage
- 20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz)
- Supported pipe diameter
- 1 1/2" (40 A), ø44 to ø55 1.73" to 2.17" 2" (50 A), ø55 to ø64 2.17" to 2.52"
- Supported pipe materials
- Metal / resin *1
- Analog output (ch.1/ch.2)
- Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less *7
- Supported fluid temperature
- - 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface) *2
- Integrated flow unit display
- 1 / 10 / 100 / 1000 / 10000 (L)
- Wiring specifications / Power supply
- DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable)
- Pipe temperature measurement accuracy
- ±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F ) ±5°C ±9°F (liquid temperature of 50 to + 120°C, 122 to 248°F ) (ambient operating temperature of 25°C 77°F ) *4
- Environmental resistance / Enclosure rating
- IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250)
- Input/Output (Selectable) / Output (ch.1/ch.2)
- Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less *7
Compatibility Information
Match FD-R50 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing FD-R50.
Maintenance Tips
Store FD-R50 dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. FD-R50 is in stock and ships within 1-2 business days, with a tracking number for every shipment.
FD-R50 is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match FD-R50 against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114