KEYENCE FD-Q32C Product overview The KEYENCE FD-Q32C is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly. Technical data - Ambient temperature: -10 to +60 °C 14 to 140 °F (No freezing) - Analog output (ch.2): 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less *5 - Current consumption: 130 mA or less (Load current excluded) *6 - Display method: Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator - Display resolution: 0.1/ 1 (Default :1) (L/min) - Display update cycle: Approx. 3 Hz - Environmental resistance / Enclosure rating: IP65/IP67 (IEC60529) - External input (ch.2): Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more *5 - Hysteresis: Variable - Input/Output (Selectable) / Output (ch.1/ch.2): Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less *5 - Integrated flow data storage cycle: Save to memory every 10 seconds - Integrated flow unit display: 1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) - Material / Sensor main unit: PPS/PES/PBT/SUS303/SUS304/SUSXM7 - Maximum rated flow: 1" (25 A): 200 L/min, 52.8 G/min 1 1/4" (32 A): 300 L/min, 79.3 G/min - Memory backup: EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) - Mounting bracket: SUS304/PA/POM/SUSXM7 - Power I/O connector: M12 4-pin connector - Power supply / Power voltage: 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS - Protection circuit: Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection - Relative humidity: 35 to 85 % RH (No condensation) - Repeatability: 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S. *4 (Specific to selected response time)) - Response time: 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s - Sensor surface: Rubber - Shock resistance: 100 m/s 2 , 16 ms pulse, 1,000 times in each of the X, Y, and Z directions - Supported fluid temperature: 0 to 85°C 32 to 185°F (No freezing on the pipe surface) *2 - Supported fluids: Various liquid [i.e. water (including DI), oils, chemicals, etc.] *1 - Supported pipe diameter: 1" (25 A), ø28 to ø37 (mm) 1 1/4" (32 A), ø37 to ø44 (mm) - Supported pipe materials: Metal pipe/Resin pipe *1 - Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions - Weight: Approx. 530 g (including mounting bracket) - Zero cut flow rate: 5 L/min (Default) *3 Condition and supply - New surplus, factory sealed original packaging - In stock, lead time 3-7 days - 12 months warranty - Worldwide shipping with tracking Before you order Compare the full part number FD-Q32C with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.

Technical Specifications

SKU
FD-Q32C
Brand
KEYENCE
Part Number
FD-Q32C
Category
KEYENCE Other Parts
Condition
new
Warranty
12 months
Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
Country of Origin
China
Weight
Approx. 530 g (including mounting bracket)
Packaging
New surplus, factory sealed original packaging
Hysteresis
Variable
Memory backup
EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)
Repeatability
0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S. *4 (Specific to selected response time))
Response time
0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s
Display method
Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator
Sensor surface
Rubber
Mounting bracket
SUS304/PA/POM/SUSXM7
Shock resistance
100 m/s 2 , 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Supported fluids
Various liquid [i.e. water (including DI), oils, chemicals, etc.] *1
Relative humidity
35 to 85 % RH (No condensation)
Display resolution
0.1/ 1 (Default :1) (L/min)
Maximum rated flow
1" (25 A): 200 L/min, 52.8 G/min 1 1/4" (32 A): 300 L/min, 79.3 G/min
Protection circuit
Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection
Zero cut flow rate
5 L/min (Default) *3
Ambient temperature
-10 to +60 °C 14 to 140 °F (No freezing)
Current consumption
130 mA or less (Load current excluded) *6
Power I/O connector
M12 4-pin connector
Analog output (ch.2)
4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less *5
Display update cycle
Approx. 3 Hz
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
External input (ch.2)
Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more *5
Supported pipe diameter
1" (25 A), ø28 to ø37 (mm) 1 1/4" (32 A), ø37 to ø44 (mm)
Supported pipe materials
Metal pipe/Resin pipe *1
Material / Sensor main unit
PPS/PES/PBT/SUS303/SUS304/SUSXM7
Supported fluid temperature
0 to 85°C 32 to 185°F (No freezing on the pipe surface) *2
Integrated flow unit display
1/ 10/ 100/ 1000/ 10000 (Default : 1) (L)
Power supply / Power voltage
20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS
Integrated flow data storage cycle
Save to memory every 10 seconds
Environmental resistance / Enclosure rating
IP65/IP67 (IEC60529)
Input/Output (Selectable) / Output (ch.1/ch.2)
Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less *5

Compatibility Information

Match FD-Q32C against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.

Installation Guide

Isolate power and follow the KEYENCE documentation for the host system when replacing FD-Q32C.

Maintenance Tips

Store FD-Q32C dry and dust-free in its packaging until installation.

Frequently Asked Questions

Customer Reviews

No reviews yet. Verified buyers can share their experience with this part.

Purchased this part? Sign in to leave a review. Only verified buyers can review.

Sign in to review

Reviews are checked by our team before they appear.

Explore More Options

Related Products

KEYENCE EH-108
KEYENCE EH-108

SKU: EH-108

KEYENCE EH-110
KEYENCE EH-110

SKU: EH-110

KEYENCE EH-110S
KEYENCE EH-110S

SKU: EH-110S

KEYENCE EH-114
KEYENCE EH-114

SKU: EH-114