KEYENCE FD-MZ50AYKP
Product information
$2,361.20 USD
Condition: newShipping calculated at checkout ( Shipping Policy · 30-Day Returns )
SKU: FD-MZ50AYKP
Alternate: FDMZ50AYKP
Brand
KEYENCE
Part No.
FD-MZ50AYKP
Warranty
12 months
Lead time
3-7 days
In Stock— Ready to ship
Worldwide shipping available
Product Description
KEYENCE FD-MZ50AYKP
Product overview
The KEYENCE FD-MZ50AYKP is an automation spare part for KEYENCE industrial automation equipment. Vcocnc supplies it for maintenance, breakdown repair and retrofit projects where the original part number has to be matched exactly.
Technical data
- Accessory: Instruction Manual, Connector cable (2.7 m 106.3" )
- Accumulated flow unit: 0.1/1/10/100/1000 (G, L) selectable
- Ambient temperature: 0 to +50 °C 32 to 122 °F (No freezing)
- Analog output: 4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value
- Applied pressure range: Max. 145 PSI (1.0 MPa)
- Conductivity of detection fluids: 5 µS/cm or higher
- Connection port: NPT3/4 (20 A)
- Control output/Accumulation pulse output/ Error alarm output: PNP open collector, max. 100 mA/ch *4 30 V or less, residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)
- Detectable fluids: Water or non-corrosive liquid
- Detection fluid temperature: 0 to +85°C 32 to 185 °F (No freezing)
- Display method: Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator
- Display resolution: 0.1/1 (G/min, L/min) selectable
- Environmental resistance / Enclosure rating: IP65
- Hysteresis: Variable
- Integration data storage cycle: Save to memory every 10 seconds
- Integration reset/bank switch input/flow zero function input: Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode
- Material / Liquid end materials: Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)
- Memory backup: EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)
- Minimum flow volume: 0.7 G/min (2.5 L/min) *5
- Other materials: Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC
- Possible display range: 0.7 - 26.4 G/min (2.5 - 100 L/min) *2
- Possible ranges to set: 0 - 26.4 G/min (0 - 100 L/min)
- Power consumption (Current consumption): Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)
- Pressure loss: Max. 1.45 PSI (0.01 MPa)
- Pressure resistance: 290 PSI (2.0 MPa)
- Rated flow range: 0.7 - 13.0 G/min (2.5 - 50 L/min) *1
- Rating / Power voltage: 24 VDC, Ripple (P-P) 10 % or less, Class 2
- Relative humidity: 35 to 85 % RH (No condensation)
- Repeatability: 0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S. *3
- Response time (chatter prevention feature): 0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable
- Shape: Built-in amplifier
- Type: Horizontal
- Vibration resistance: 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Weight: Approx. 1,130 g
Condition and supply
- New surplus, never used
- In stock, lead time 3-7 days
- 12 months warranty
- Worldwide shipping with tracking
Before you order
Compare the full part number FD-MZ50AYKP with the label on your original unit, including any suffix or revision code. Contact Vcocnc if you need help confirming compatibility.
Technical Specifications
- SKU
- FD-MZ50AYKP
- Brand
- KEYENCE
- Part Number
- FD-MZ50AYKP
- Category
- KEYENCE Other Parts
- Condition
- new
- Warranty
- 12 months
- Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair. Warranty policy
- Country of Origin
- China
- Type
- Horizontal
- Shape
- Built-in amplifier
- Weight
- Approx. 1,130 g
- Accessory
- Instruction Manual, Connector cable (2.7 m 106.3" )
- Packaging
- New surplus, never used
- Hysteresis
- Variable
- Analog output
- 4-20 mA, max. load resistance 260 Ω Analog output range can be set to any value
- Memory backup
- EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)
- Pressure loss
- Max. 1.45 PSI (0.01 MPa)
- Repeatability
- 0.5 s : ±5% of F.S., 1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S. *3
- Display method
- Dual row display with 4-digit, 7 segment LED, bar display (2 colors), output indicators, flow indicator
- Connection port
- NPT3/4 (20 A)
- Other materials
- Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC
- Rated flow range
- 0.7 - 13.0 G/min (2.5 - 50 L/min) *1
- Detectable fluids
- Water or non-corrosive liquid
- Relative humidity
- 35 to 85 % RH (No condensation)
- Display resolution
- 0.1/1 (G/min, L/min) selectable
- Ambient temperature
- 0 to +50 °C 32 to 122 °F (No freezing)
- Minimum flow volume
- 0.7 G/min (2.5 L/min) *5
- Pressure resistance
- 290 PSI (2.0 MPa)
- Vibration resistance
- 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions
- Accumulated flow unit
- 0.1/1/10/100/1000 (G, L) selectable
- Applied pressure range
- Max. 145 PSI (1.0 MPa)
- Possible display range
- 0.7 - 26.4 G/min (2.5 - 100 L/min) *2
- Possible ranges to set
- 0 - 26.4 G/min (0 - 100 L/min)
- Rating / Power voltage
- 24 VDC, Ripple (P-P) 10 % or less, Class 2
- Detection fluid temperature
- 0 to +85°C 32 to 185 °F (No freezing)
- Integration data storage cycle
- Save to memory every 10 seconds
- Material / Liquid end materials
- Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)
- Conductivity of detection fluids
- 5 µS/cm or higher
- Power consumption (Current consumption)
- Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)
- Response time (chatter prevention feature)
- 0.5 s/1 s/2.5 s/5 s/10 s/30 s/60 s variable
- Environmental resistance / Enclosure rating
- IP65
- Control output/Accumulation pulse output/ Error alarm output
- PNP open collector, max. 100 mA/ch *4 30 V or less, residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)
- Integration reset/bank switch input/flow zero function input
- Input time : 20 ms or greater,Select either the accumulation output or the accumulation pulse by setting the mode
Compatibility Information
Match FD-MZ50AYKP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Installation Guide
Isolate power and follow the KEYENCE documentation for the host system when replacing FD-MZ50AYKP.
Maintenance Tips
Store FD-MZ50AYKP dry and dust-free in its packaging until installation.
Frequently Asked Questions
Yes. FD-MZ50AYKP is in stock and ships within 1-2 business days, with a tracking number for every shipment.
FD-MZ50AYKP is supplied with a warranty of 12 months. Covers manufacturing defects and functional failures under normal use; excludes damage from improper installation, misuse or unauthorized repair.
Match FD-MZ50AYKP against the original part label and the machine or panel configuration before ordering; suffixes and revision codes matter.
Customer Reviews
No reviews yet. Verified buyers can share their experience with this part.
Purchased this part? Sign in to leave a review. Only verified buyers can review.
Sign in to reviewReviews are checked by our team before they appear.
Explore More Options
Related Products
KEYENCE EH-108
SKU: EH-108
KEYENCE EH-110
SKU: EH-110
KEYENCE EH-110S
SKU: EH-110S
KEYENCE EH-114
SKU: EH-114